Operational Works Application OPW17/0039

of 81

Page text shows just the words. Original shows the document exactly as it was published.

Very large file: it may take a few minutes

The original of this document is very large (22.3 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.

..
                                                    Sofitel Noosa Sign 1
                                                                                                                   SCF477A_a        RevO

     \'ISTEI(
     STr;t.r.Tt.~A'    +   (;lVll    F"1,r,I"~FR5
                                                    Wall Mounted Sign WM[4xO.3x21]
                                                    14-16 Hastings St.
                                                    Noosa OLD 4567
                                                                                                                     21-Jan-17        2


      INTRODUCTION:

      SCOPE:                        Engineering     design and details for wall mounted sign.
                      1.            Design loads:
                                       Dl           Sign dead load [self weight]
                                       Wl           Wind load [Region & Terrain Category]
                                       El           Earthquake    load [where applicable)
                      2.            Design and detail letter structural arrangement
                      3.            Design and detail support frame structure
                      4.            Design and detail fixings to existing wall structure.
                                    NB: Existing     wall structure   by others


      REGULATIONS                   & CODES:
                                    BCA. 2016: Building Code of Australia - 2016
                                    AS/NZS 1170.0 - 2002: Structural design actions Part 0: General principles.
                                    AS/NZS 1170.1 .2002:         Structural design actions Part 1: Permanent. imposed & other actions.
                                    AS/NZS 1170.2 - 2011: Structural design actions Part 2: Wind actions.
                                    AS 1170.4 - 2007: Structural design actions Part 4: Earthquake          actions in Australia.
                                    AS/NZS     1664.1 - 1997: Aluminium     structures Part 1: Limit state design.
                                    AS 3566 - 2002: Seif-drilling     screws for the building and construction    industries ies.
                                    AS 3600 - 2009: Concrete structures
                                    AS 4100 - 1998: Steel structures.
                                    AS/NZS 4600 - 2005: Cold-formed         steel structures.




       MATERIALS:                                                                                                     fy (Mpa)      fu (MPa)

       Hot Rolled                   UB. UC, PFC: Grade 300 (AS/NZS 3679.1 - 2010)                                       300           440
                                    Plate: Grade 250 (AS/NZS 3678 - 2011)                                               250           410

       Cold Formed                  SHS: Grade C450 (AS1163 - 2009)                                                     450           500
                                    RHS: Grade C450 (AS 1163 - 2009)                                                    450           500
                                    CHS: Grade C350 (AS 1163 - 2009)                                                     350          430
                                    CA: Cold-formed      angle (Duragal)                                                 350          400
                                    CC: Cold formed channels (Duragal)                                                   400          450
                                    CF: Cold-formed      flats (Duragal)                                                 350          400

       Bolts                        Bolts (4.6/S)    - [Commercial)                                                      240          400
                                    Bolts (8.8/S)    - [High Strength Structural]                                        660          830

       Welds                        Welding     • Category: General Purpose                                              GP           410
                                       100% Visual scanning.       10% Visual examination       (Table 6.2.2 AS/NZS 1554.1: 2014)
                                    Welding     - Category: Structural Purpose                                           SP           410
                                       100% Visual scanning.       10% Visual examination       (Table 6.2.2 AS/NZS 1554.1: 2014)
       Concrete:                    Grade N25        [fc @ 28 days)                                                      25           MPa

       REFERENCES:
                                    Duragal Easy Welding Guide.
                                    Duragal Easy Painting & Corrosion Protection Guide.
Log in to download the original file

Operational Works Application OPW17_0039.pdf · 22.3 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.