Original source · versioned page text
Operational Works Application OPW17/0039
Very large file: it may take a few minutes
The original of this document is very large (22.3 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Sofitel Noosa Sign 2
SCF477A_b Rev 0
\(ISTEI(
~TPUCTlJ~/l1 - •. IV r"lG1NrrR!O
Wall Mounted Sign WM(8x1.2x11)
14-16 Hastings St,
24-Jan-17 5
Noosa OLD 4567
WIND PRESSURE:
Param Detail I Formula Value Units
Site
Item
REG Region B ...
•••
Il
TC
Importance level
Terrain Category
2
2.5
...
R Average Recurrence Interval 500 •••
VR Regional wind speed for R 57.0 mls
Geometry b Average width of sign face 8.00 m
c Height of sign face 1.23 m
h Total height of sign above datum 0.80 m
Ac. Proportion of c1added area 0.20 ••
A, Area of sign face 1.97 m'
h. Height of datum above NGl (z = 0) 10.00 m
z Height above NGl (rounded up) 11 m
WIND lOAD Cdyn Dynamic response factor 1.00
..
1.00 ••
k.
k,
Area reduction factor
Combination factor 1.00 ..
Select sign location Near wall edge (h <: 25m)
..
k,xC •• local pressure factor 1.30
..
kp Porous cladding factor 1.00
..
Terrain
C,g
M,
Aerodynamic Factor (Cfig=Cpe.ka.kc.kl.kp)
Terrain & height multiplier
1.30
0.93
...
Pressure p, Pressure at ht z 1.67 kPa
STR p. Strength design pressure 2.17 kPa
SRV P. Serviceability design pressure 1.45 kPa
Force W, Total wind load on sign face 4.3 kN
DL G Self weiQht of siQn 1.0 kN
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.