                                               Sofitel Noosa Sign 2
                                                                                                                  SCF477A_b         Rev 0

"ISTEI(
~lF:t.CTt.RAI   .• r.IVll    !=1,GI!l:i='FRS
                                               Wall Mounted Sign WM[8x1.2x11)
                                               14.16 Hastings SI.
                                               Noosa OLD 4567
                                                                                                                      24.Jan.17        2


 INTRODUCTION:

 SCOPE:                     Engineering        design and details for wall mounted sign.
                1.          Design loads:
                                DL             Sign dead load [self weight]
                               WL              Wind load [Region & Terrain Category)
                                EL             Earthquake     load [where applicable)
                2.          Design and detail letter structural arrangement
                3.          Design and detail support frame structure
                4.          Design and detail fixings to existing wall structure.
                            NB: Existing        wall structure      by others


 REGULATIONS                 & CODES:
                            BCA. 2016: Building Code of Australia.                 2016
                            AS/NZS 1170.0 • 2002: Structural design actions Part 0: General principles.
                            AS/NZS 1170.1 • 2002: Structural design actions Part 1: Permanent,                   imposed & other actions.
                            AS/NZS 1170.2.2011:             Structural design actions Part 2: Wind actions.
                            AS 1170.4.2007:          Structural design actions Part 4: Earthquake          actions in Australia.
                            AS/NZS 1664.1.1997:             Aluminium        structures Part 1: Limit state design.
                            AS 3566.2002:          Self.drilling    screws for the building and construction     industries ies.
                            AS 3600 • 2009: Concrete structures
                            AS 4100 .1998:         Steel structures.
                            AS/NZS 4600 • 2005: Cold. formed steel structures.




  MATERIALS:                                                                                                           fy (Mpa)     fu (MPa)

  Hot Rolled                UB, UC, PFC: Grade 300 (AS/NZS 3679.1 .2010)                                                 300          440
                            Plate: Grade 250 (AS/NZS 3678 • 2011)                                                        250          410

  Cold Formed               SHS: Grade C450 (AS1163.                 2009)                                                450         500
                            RHS: Grade C450 (AS 1163.2009)                                                                450         500
                            CHS: Grade C350 (AS 1163 • 2009)                                                              350         430
                            CA: Cold.formed         angle (Duragal)                                                       350         400
                            CC: Cold formed channels               (Duragal)                                              400         450
                            CF: Cold.formed         flats (Duragal)                                                       350         400

  Bolts                     Bolts (4.6/S)       • [Commercial)                                                            240         400
                            Bolts (8.8/S)       • [High Strength Structural]                                              660         830

  Welds                     Welding        • Category: General Purpose                                                    GP          410
                               100% Visual scanning,           10% Visual examination        (Table 6.2.2 AS/NZS 1554.1: 2014)
                            Welding        • Category: Structural Purpose                                                 SP          410
                               100% Visual scanning.           10% Visual examination        (Table 6.2.2 AS/NZS 1554.1: 2014)
  Concrete:                 Grade N25           [fc @ 28 days)                                                            25          MPa

  REFERENCES:
                            Duragal Easy Welding Guide.
                            Duragal Easy Painting & Corrosion                  Protection Guide.
Log in to download the original file

Operational Works Application OPW17_0039.pdf · 22.3 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.