                                                           Sofitel    Noosa      Sign 1
                                                                                                                                    SCF477A_a            Rev 0

         \(ISTEI{
         STRt,;cn   ..•pJ.L   I CIV'. EI\G   I\O;::Er<S
                                                           Wall


                                                           Noosa
                                                                     Mounted
                                                            14-16 Hastings
                                                                      OLD 4567
                                                                                 Sign WM[4xO.3x21]
                                                                                   St.
                                                                                                                                    21-Jan-17              9

          GENERAL              NOTES:

          General:                1. All materials, fabrication and installation shall be in accordance INith the SGA and
                                     relevant SAA codes (current edition induding               all amendments)
                                  2. Client is responsible           for all dimensions. measurements    and other site information
                                     reaujred to complete the enaineerinQ design and details.

          Sleel                    1. All work and materials shall be in accordance with the following:
                                                          Hal-rolled sleel: AS 4100 -1998
                                                          Cold.formed        steel: AS/NZS 4600 - 2005
                                                          Stainless steel: AS/NZS 4673 - 2001

                                  2. Sections:              UB. UC, PFC & Plale: Grade 300 (AS/NZS 3679.1 -2010)
                                                            RHS & SHS: Grade C450 (AS 1163-2009)
                                                            CHS: Grade C350 (AS 1163 - 2009)
                                                            Cold-formed        Duragal: CA = Equal Angle, CC = Channel, CF = Flat

                                                            Stainless steel Grade 304 or Grade 316 (uno).
                                   3. Ends of all hollow sections shall be sealed with 3 mm olate.

          Aluminium:               1. All work and materials shall be in accordance with AS/NZS 1664 - 1997.
                                   2. Structural sections:           Alloy - Temper: 6060 - T5 (uno)
                                   3. Plale: Allov.        Temoer:      5005- H34 (uno)

           Concrete:               1. All work and materials shall be in accordance with AS 3600 - 2009.
                                   2. Concrele shall be Grade N25 (fc = 25 MPa @ 28 days), (uno)
                                   3. Concrete shall be compacted using mechanical vibration.
                                   4, Minimum cover to hold-down bolts or other titments shall be 75 mm.(uno)
                                   5. Concrete shall be cured for 7 days before imoosinQ any structural loads.

           Welding                 1. Welding of structural steel shall be in accordance with AS/NZS 1554.1 - 2011.
                                   2. Welding of cold - formed steel shall be in accordance              'Nith AS/NZS 1554.1 - 2011
                                   3. Welding of stainless steel shall be in accordance with AS/NZS 1554.6 - 1994.
                                   4. Welding of aluminium shall be in accordance VoIithAS/NZS 1665 ~2004
                                   5. Welds shall be CateaoN - GP (uno), done bv a suitablv Qualified welder.

           Bolts                   1. Bolls shall be M16(4.6/S) galvanised (uno).
                                   2. Hold.down bolts (HD-bolls) shall be M24(4.6/S) galvanised (uno)
                                   3. Stainless steel bolts shall be Grade 304 or Grade 50 OSO)

           Screws                  1. Self-Tapping         (self-drilling)    metal screws shall be in accordance with AS 3566 Parts 1 & 2.

                                   2. Screw size designation             shall be as follows:
                                                          S14.8 (No.10)                                                         Dia. = 4.8mm

                                                          ST5.5 (No.12)                                                         Dia. = 5.5mm

                                                          ST6.3 (No.14)                                                         Dia. = 6.3mm

                                      Corrosion Resistance:

                                      Class - 2           General internal use.

                                      Class - 3           General external use.

                                      Class - 4           External use in severe marine environment.

           VHB - Tapes              1. VHB - Tapes Nery High Bond - Tapes) shall be either 3M or Biolink.
                                   2. VHB - Tapes shall be used to resist dynamic wind loads only.
                                   3. Surfaces to be joined shall be prepared in accordance with manufacture's                specifications

                                       and requirements.
                                   4. VHB.       Tanes shall be annlied in accordance Ytr'ithmanufacture's         soecifications    and renuirements.

            Sealant                 1. All joints that are not welded and abutting surfaces should be sealed with a structural sealant.
Log in to download the original file

Operational Works Application OPW17_0039.pdf · 22.3 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.