EXISTING METAL FLASHING
EXISTING STEEL POST BEHIND TIMBER BATTENS
STAINLESS STEEL TENSION WIRE ROPE SUPPORT TO CANOPY
20 x 150mm TIMBER-LOOK SCREEN / PRINT ALUMINIUM SLATS/BATTENS
TO EXISTING STEEL POSTS
880
FIXED GLASS PANEL IN POWDER COATED ALUMINIUM FRAME
LIQUID APPLIED WATERPROOFING TO MARINE GRADE PLYWOOD
CLADDING TO CANOPY ROOF
200PFC BEAM TO FORM FRAME OF NEW CANOPY;
200
TO STRUCTURAL ENGINEER'S DETAILS
PAINTED TIMBER CLADDING TO UNDERSIDE OF CANOPY
FOLDING SLIDING TRACK FIXED TO NEW HANDRAIL
STAINLESS STEEL DOWNPIPE TO DRAIN CANOPY TO BE
FIXED TO OUTSIDE OF EXISTING STEEL POST
SINGLE-GLAZED POWDER COATED ALUMINIUM FOLDING
NORTH EAST CORNER OF BUILDING WITH PROPOSED FOLDING SLIDING SCREENS IN OPEN POSITION SLIDING SCREENS
1,910
1,395 470
-
NOOSA COUNCIL 1,920
APPROVED PLANS
132004.4078.08
8 MAY 2017
HARDWOOD WINDOW SILL
ALUMINIUM FRAMED FIXED GLAZING BALUSTRADE
EXISTING STEEL POST (ASSUMED TO BE 200 x 100mm) FIXED TO EDGE
OF RC SLAB
1,000
FIRST FLOOR FFL 7.400
NEW STEEL ANGLE FIXED TO EDGE OF SLAB
EXISTING RC SLAB AND EDGE BEAM
NORTH EAST CORNER OF BUILDING WITH PROPOSED FOLDING SLIDING SCREENS IN CLOSED POSITION
NHSLSC | PROPOSED ALTERATIONS M1601
3 18 1
3/ 27 IZ ET T S T R E E T
EXTERNAL FOLDING SLIDING GLASS SCREENS DA109
M E L B O U R N E
1:20@A3 10|04|2017 A RCHIT ECT S
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
SUPERSEDED Compiled Plans 132004.4078.09.pdfRelated documentApplication case desk ↗
About this file
- File size
- 5.9 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.