AS2303:2018-Tree Stock for
Landscape Use compliant tree
stock with Arborist certification -
refer to Specification notes.
Species and pot size as per
schedule. Stem taper finished flush
with finished soil level, allow for
settlement.
38x38x1800mm Hardwood stakes
driven into ground avoiding
rootball.
Woven polyethylene based
polyfabric tree tie. 50mm width.
Secured loosely with figure eight
loop and fixed to stake with
galvanised stapes
Guying ties 2/3 up trunk
100mm depth organic mulch as per
Specification - avoiding contact with 1 2
tree stem.
100mm mulch as per specification
x
2 ma 4
in 1 Tubestock as per reveg plan and schedule.
1
Planting hole two times wider than plant pot size.
2 Coir 4 mesh pinned as per Manufacturer's specification
5 over 100mm depth organic mulch as specified.
Excavate tree pit to the depth of 3
rootball and cultivate to a width of 3 Slow release fertilizer as per Manufacturer's
5
recommendations. Choose appropriate fertilser for species
100
2-3 times the diameter of rootball.
Rip the edges of the pit and back fill selection.
with topsoil as per specification 4 Min.100mm deep ameliorated topsoil spread across
100
planting area as per recommendations of Agronomist
6 Report.
150
5 300mm length galvanised pins.
Slow release fertilizer and water 6 150mm depth ripped and 'stepped' ameliorated subsoil.
retention crystals installed as per 7 Subgrade as profiled by Civil Contractor.
manufacturers recommendations.
Choose appropriate fertilser for De-compacted subsoil to 150mm
species selection. depth.Ensure all garden bed areas 7
and tree pits are free draining.
Existing subgrade Existing subgrade
Diameter of hole 3x Rootball width
1 TYPICAL TREE PLANTING DETAIL - 25L 2 TYPICAL REVEGETATION PLANTING PROFILE 3 TYPICAL TUBESTOCK PLANTING DETAIL IN COIR
- Scale 1:10 - Scale 1:10 - Scale 1:10
Approved by: Ryan Cairney (AILA)
Checked - RC
Consulting Civil & Drawing title - Project - Site - Project No. 213029 Sheet No. L201
Design - RC Drawn - RC
E 15/08/24 FOR APPROVAL RC
LANDSCAPE DETAILS PROPOSED DEVELOPMENT 41 PICTURE POINT CRES, NOOSA HEADS
D 01/07/24 FOR APPROVAL RC Structural Engineers Digital Ref : 213029 Issue : E
C 25/06/24 FOR APPROVAL RC
Scales - AS SHOWN B 24/06/24 FOR APPROVAL RC
Project Management 124 DUPORTH AVENUE Ph (07) 5443 7777 Client - This Document is copyright and shall not be copied
Document Stage - APPROVAL
A 20/06/24 FOR APPROVAL RC ASSOCIATES PTY LTD
& Planning
PO BOX 16
MAROOCHYDORE QLD 4558
Fax (07) 5443 7577
K CARROLL & H MEYER without written approval, nor shall it be used except
for the Development and the Site Specified.
Issue Date Description By E-MAIL: [email protected]
20
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.