Development Application Part 2 of 3 Report MCU13/0106

of 54

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

Very large file (27.9 MB): the whole original can take several minutes to open, especially on a phone. Text is quick to read.

                                                                                                                                                                                               12



                                                                                                                                 shown in Section 3 of this report. It follows, the
                                                                                                                                 proposed detached dwelling and garage (10a
                                                                                                                                 structure) maintains the visual continuity and
                                                                                                                                 pattern of the buildings within the street.

                                                                                                                            Refer to the elevations included in Attachment D.
Water conservation and storage
018 On-site water storage is provided, designed and     S18.11f not in a water service area each Detached house is          The subject site, located within Council’s water          018 and 019

operated to support the efficient use of water and is   to be serviced with a rainwater tank of the following minimum       service area, will be connected to the reticulated
adequate for occupants every day use.                   storage capacity:-                                                  water supply system. This supply will be adequate for
                                                        a) For Detached houses with no more than 3 bedrooms           -

                                                                                                                            firefighting purposes.
AND                                                           45,000 litres; or
                                                        b) For Detached houses of more than 3 bedrooms or
019 Detached houses, Ancillary dwelling units              where including a 2nd dwelling unit on the same premises
and Multiple housing Type 1 within Bushfire                   -
                                                                60,000 litres;
Hazard Areas have sufficient water supply for fire
fighting purposes.                                      AND


                                                        S19.1 If not in a reticulated water service area- there is, on
                                                        the lot, a dam, swimming pool or water tank accessible for
                                                        use   by the fire brigade, that contains at least 5,000 litres of
                                                        water.


                                                        Advisory note
                                                        The 5,000 litres required in S23.1 can be included within the
                                                        water required in S22.1 providing it is accessible for the
                                                        purpose of fire fighting at all times and not used for other
                                                        domestic purposes.
Effluent Disposal
020 Effluent disposal does not have a significant       No solution provided      (no requirement for selfassessable        The subject site is located within Council’s effluent     020 and 021
adverse effect on biodiversity, natural vegetation or   development)                                                        treatment and disposal area, and will be connected to
water quality18.                                        Advisory note                                                       the system. It follows, the development will not have
021 Treatment and disposal of wastewater does not       PSP24      -
                                                                       Effluent Disposal details requirements for the       any adverse impacts on biodiversity, natural
have any detrimental impact on Noosa’s major water      design and siting of effluent disposal systems where located        vegetation or water quality.
storage and supply   -
                         Lake Macdonald.                outside a sewerage service area. Compliance with PSP24
                                                        will be considered as part of Council’s assessment of the
                                                        plumbina and drainaae application.
Environmental Protection

Used in these records

About this file

File size
27.9 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Development Application Part 2 of 3 Report MCU13_0106.pdf · 27.9 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.