                                                                                                                          Page 2


OUR REF:
ADDRESS:
             12.2452
            LOT 9(#18)TROPICANA
            RISE, CASTAWAYS BEACH
                                                                       ml)C!l
                                                                      Design Engineers Queensland
                                                                              Consulting Engineers
                                                                        Civil, Structural and Soil Testing
                                                                          DEC Coosuttlno Ply LId Va   ABN 53065 711 248




2. IS EXISTING FILL PRESENT ?                      DYes          0No
 IS EXISTING FILL> 400mm IN DEPTH                  DYes          oNo Refer Comments above
                                                                          -
                                                                                      to


  DOES FILL APPEAR SUITABLE FOR                    DYes          oNo Refer Pier Requirements below
                                                                          -




  RE-COMPACTION



3. ARE FOOTING PIERS REQUIRED?                     0Yes          DNo
 oSCREW P RS ARE REQUIRED (SEECOMMENTS)
 oP RS ARE REQUIRED THROUGH PAD FILL INTO FIRM EXISTING FILL.
 oP RS ARE REQUIRED THROUGH ALL FILL AND NATURAL SOILS INTO WEATHERED ROCK.

4. ARE SLAB PIERS REQUIRED?                        oYes           DNo
 oSCREWP RS ARE REQUIRED (SEECOMMENTS)
 oP RS ARE REQUIRED THROUGH PAD FILL INTO FIRM EXISTING FILL.
 D P RS ARE REQUIRED THROUGH ALL FILL AND NATURAL SOILS INTO WEATHERED ROCK.

s. TREES OF POTENTIAL FOUNDATION INFLUENCE                               -
                                                                             See Comments


 DN/A         oNOTED ON SITE                  G NOTED ON ADJACENT SITE
                         TO REMAIN, AN EXPERT ARBORIST SHOULD BE COMMISIONED TO
 D IF EXISTING TREES AREROOT BARRRS OR OTHER PHYSICAL METHODS ARE REQUIRED
    ASCERTAIN WHETHER



6. WIND CLASSIFICATION

 DN2(W33N)                    0N3(W41N)                              DN4(WsON)




               No.5 Parkview Street, Milton   Qld 4064 Phone: (07)33670211 Fax: (07)33670205
                                         Email: soiltestin.com.au

Used in these records

About this file

File size
27.9 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Development Application Part 2 of 3 Report MCU13_0106.pdf · 27.9 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.