Development Application Part 2 of 3 Report MCU13/0106
Very large file (27.9 MB): the whole original can take several minutes to open, especially on a phone. Text is quick to read.
8
04 Filling or excavation does not adversely affect 54.1 Fill material placed over services does not impose any Sewer and water utility infrastructure is not located
sewer, stormwater or water utility infrastructure. additional surcharge loading on the service. within the subject site (confirm this is true). It follows,
filling or excavation will not adversely affect sewer,
54.2 Where excavation is carried out storrnwater or water utility infrastructure.
a) a minimum cover of 600mm is maintained around all
utility infrastructure (to top, sides and base of services);
or
b) a retaining wall is provided to support the soil
surrounding the service;
AND
54.3 Compaction with a vibrating roller is not carried out
within 600mm of any utility infrastructure.
05Development does not adversely impact S5.1 Buildings or other structures within the Not applicable. The subject site is not located within NA
on the Lake Macdonald water supply. Lake Macdonald catchment (indicated on Figure the Lake Macdonald Catchment.
14.7) are located above the 98.5m AHD level.
Electricity supply infrastructure
06 Uses and works maintain adequate safe
an S6.1 Buildings and structures (including swimming pools, The proposed buildings and structures are not 56.1
distance from electrical infrastructure
including sheds, tennis courts or outbuildings) are not constructed located under overhead electricity transmission lines.
substations, overhead powertines, power poles and under overhead electricity transmission lines, or wfthin
transfonners. electricfty easements. The subject site does not contain, and is not located
nearby any electricity easements.
Steep Slopes and Landslide hazard areas
07 Detached houses, Ancillary dwelling units, S7.1 If on premises iden ed as a Landslide Hazard Area on Refer to Attachment C for a geotechnical report, S7.2 and 7.3
Multiple housing Type 1 and associated uses are Overtay Maps OM1.3-9.3, or on steep slopes the use does prepared by Morrison Geotech which identifies the
sfted or constructed to maintain the safety of people not- site slippage risk and recommendations to mitigate
and properly from the risk oflandslide. a) involve the removal of vegetation other than grass from soil slippage during and after construction.
use areas; or
b) involveexcavating or filling of more than 50m3 of The recommendations in the geotechnical report will
material (other than placement of topsoil not exceeding be implemented.
100mm in depth relative to natural ground level; or
c) involve cut or fill with a depth of more than 2m relative to
natural ground level; or
d) redirect or impede water flows in an existing watercourse
or stormwater drain; or
e) involve construction of an on-site effluent disposal
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Development Application Part 2 of 3 Report MCU13/0106Related documentApplication case desk ↗
About this file
- File size
- 27.9 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.