202303 Wyandra - REV A
The original of this document is very large (10.4 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Original PDF page 1, section 1. The text section number identifies this passage in the reader.
B L A C K
W O O D
Wyandra
New duplex located at 12 Wyandra Street
Noosa Heads Qld 4567
a r c h i t e c t u r e
architectural DA package
for development approval - issue A 30/08/2022
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.
Full text of sections 2 to 5 (of 33)
Section 2
Contents
Client & Prepared for:
Integra Partnerships DA1 SITE PLAN
DA1.01 COVER PAGE
DA1.02 CONTENTS
Job No: DA1.03 LOCATION
202303 - Wyandra DA1.04 EXISTING SITE PLAN
DA1.05 SITE PLAN
By: DA1.06 12 + 14 Site plan
Blackwood Architecture & Design DA2 FLOOR PLANS
25/91 Poinciana Avenue, Tewantin DA2.01 LOWER FLOOR UNIT 1
DA2.02 UPPER FLOOR UNIT 1
QLD 4565
DA2.03 ROOF UNIT 2
07 5301 9677
DA2.04 LOWER FLOOR UNIT 2
0416 037 424 DA2.05 UPPER FLOOR UNIT 2
DA2.06 ROOF UNIT 2
www.blackwoodarchitecture.com.au DA3 ELEVATIONS + SECTIONS
[email protected] DA3.01 NORTH ELEVATION
DA3.02 EAST ELEVATIONS
Phil Tillotson - DA3.03 SOUTH ELEVATION
QLD Registered Architect #5386 DA3.04 WEST ELEVATION
DA3.05 SECTION A
The designs and drawings contained in this document are the
DA3.06 SECTION B
copyright of Blackwood Architecture and shall not be DA3.07 SECTION C
reproduced, copied or used in any other context other than the DA3.08 SECTION D
project and site specified. The proposal herewith are conceptual,
DA3.09 SECTION E
subject to change and not to be used for construction or sales
and marketing. DA4 DESIGN EXPLANATION
DA4.01 DESIGN STRATEGY + INSPIRATION
DA4.02 MATERIALS + FINISHES PALETTE
DA4.03 3D RENDER
DA4.04 3D RENDER
DA4.05 3D RENDER
DA4.06 3D RENDER
DA4.07 3D RENDER
DA4.08 3D RENDER
DA4.09 3D RENDER
DA4.10 3D RENDER
DA4.11 3D RENDER
DA5 PLANNING INFORMATION
DA5.01 SITE COVER + LANDSCAPING
Drawing Register DA5.02 GFA
Issue Date Description Checked DA5.03 POS
A 30/08/2022 Issued for co-ordination PT DA5.04 END PAGE
B L A C K
W O O D
a r c h i t e c t u r e
Section 3
ST
RA
D
N
YA
#16
W
SITE
#14
#12
Location Plan Aerial Photo
NTS NTS
GENERAL NOTES
SITE ADDRESS 12 Wyandra Street Noosa Heads Qld 4567
LOT LOT 43 RP139776
LOCAL AUTHORITY Noosa Shire Council
SITE AREA 761.84m2
B L A C K Job No: Project: Date Drawing No.
LOCATION 202247 Wyandra 30/08/2022 DA1.03
W O O D
Revision Scale
a r c h i t e c t u r e & d e s i g n 12 Wyandra Street Noosa Heads Qld 4567
For Integra Partnerships A @ A3
Section 4
Rid
ge
RL
34
.90
31.
31
.8
95
9
Gu
3 2 .3
tte 32
rR
L3 32.
3.1
3
1
3 32 4
.15
42
Tels
B RP139776
W
32
.57
A C D E
tra P
32.82
32.64
it
32
135
32
5.29
.9
2
.73
RL3
Roof
RP160425
33
PALM 0.60
505
32.9
33.25
33.4
3
3.
5
33.2
30.17
3 2
7
32.94
0
0"
RL M ( S
7
52'0
45°5
TB
3 1 5°
33.
3
38
GREV 0.2080
3
10.5
32.9
.52crew
4
2'00
33
.6
5
2
AH in
35
32.7
33.2
33 33.58
Gutter RL33.26
"
33.5
PA
D K
8
33
LM
4
.69
1
33
33
0.3 33.47
.7 2
. 61
33.60 33.59Grated Drain
050
33
33.5
+33.75
33.2
33.5
erb
33.67
Driveway
5
.7
+32.50
6
4
Concrete
0
5
)
W
32
.6
AT
1 Level RL33.67
1
6
+33.50 +34.05
0.
Garage Floor
rds
33.99
3
33
eco m
09
34
RL M ( S
.96
34
er Red Froole
TB
.00 Section 5
34.07
t
0
Po
a
3 4 cre
ty W2Plotrt Manh
7
225°
2
33
Uni
33.6
ol
.0 9 w
34
e
.7
3
Sew
34
Fire Hydrant
1
3.65 33 33 67
7
Co
WYAND
LIL
.0 3
6.35
+34.17
52'0
34
.2 0
A
Eq ool
33.6
.24
pin
P
HDin Ke
0
uip
2
33.61 8
Gutter RL37.20
.3 0
.83
5
34
0"
g
.1
33 34
80
RL
34.22
2
.63 .2
+34.06
34.0
34.0
2
N
33
8
rb)
5
PA
43
.6
LM
6
0 step +33.70
.5 0
61°39'00"
S t a De
18.900
33
34.5
8
Gutter R
.4
04
3 3
Gutter R
5
G
2
i r s ck
33.7
PA
33.6
RE
3
LM
5
+34.55
9
4 .4
+34.50 +34.30
134
V0
P A 0 .2
L35.76
2
34.
LM 0 7 +34.15
L38.36
Roof RL37.35 53
.3
RP160425
S 0 .6 0 4
10
RA STRE
05
LIG
0
05 RL34.59
6
RL37.30
H
4 4
241°39'00" PA3
Floor Level
T
Roof 34
.8
+35.30 +35.30
35.11
35
34.83
STREET
34.99
35.09
TBM (Screw in Kerb)
of 35
Bitumen
RL34.09 AHD Edge Pit
of
Kerb
34. 64
Telstra
34.75
Back Meter
TBM (Screw in Kerb)
34.20
Water
RL33.52 AHD 34.42
34
34.53
35.42
0.60504
34.12 34.98
PALM
34.22
RL37.73
33.40
34.55
35.09
Gutter
WYANDRA
33.96
34.03
33.70 Hydrant 61°39'00"
0.20807
35.05
18.900
35.08
33
Fire 34.83
WAT 0.30807
WAT
34.56
33.58
33. 61
33.99
34.00
34 .07 LIGHT
33.27
53
34.88
33.38
34.24 GREV 0.31006 34.48
34
RL40.48
Roof 44
32.33 RP139776
RL37.30
34.48
Roof
34.54
34.72
The text continues on section 6.