Original source · versioned page text
Attachment 5 - Environmental Noise Assessment
Table 4.2: Source Sound Power Levels
Octave Band Centre Frequency, dB (Hz)
Description Overall dB(A)
63 125 250 500 1k 2k 4k
Automated Carwash entry/exit (without
82 83 84 85 87 86 85 92
doors)
Automated Carwash entry or exit with
closed automatic PVC 3mm door 70 75 72 71 65 61 53 71
(achieving Rw 23)
Manual wash bay (including super wash
79 80 80 82 83 83 80 88
bay)
Vacuum (unattenuated) 85 80 82 80 81 82 85 92
Dog Wash bay 70 71 71 73 74 74 71 79
3 Phase Vacuum System 75 70 72 70 71 72 75 79
Vehicles starting and moving around site 96 89 85 83 79 78 70 85
Car doors shutting 97 90 86 84 80 77 71 86
Air Conditioning Condenser Unit 80 82 81 80 77 73 70 82
Exhaust Fan 58 61 65 52 51 50 65 67
4.1.4 Three-Dimensional Site Render
Figure 4.1 presents the 3-dimensional render showing the site and surroundings from the north-
west perspective. Figure 4.2 presents the 3-dimensional render showing the site and surroudings
from the south-east perspective.
Residential Residential
Commercial
Commercial
Auto Bays Plant
Room Manual Bays
Take-Away
Coffee
Commercial