Skip to the record
Accept no imitations.

Council archive · source document

Part 5 of 37 Appendix 3 - Civil Engineer Report MCU12/0208

of 50

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

Very large file (37.5 MB): the whole original can take several minutes to open, especially on a phone. Text is quick to read.

Original PDF page 18, section 1. The text section number identifies this passage in the reader.

                                                                                                   Engineering Report
                                                                                                     Noosa on Weyba




7               Integrated Water Cycle Management Plan

An Integrated Water Cycle Management Plan (IWCMP)has been prepared by Gilbert and Sutherland. The
ICWMP considered several servicing options for the development and recommends Option 4 as the

preferred servicing strategy. Option 4 assumes sewage is treated off-site at the Noosaville STP and
maximises rainwater harvesting at each residence.

The recommendations of the IWCMP will be adopted as part of the WSUD strategy for the site. Rainwater

harvesting will be maximised through the connection of all available roof area to the tank and the utilisation
of rainwater tank sizes around twice the size prescribed by the Queensland Development Code. Collected
rainwater will be used for irrigation, toilet flushing and laundry purposes. This will significantly reduce the

potable water demand of the site.
For further details refer to the IWCMP prepared by Gilbert and Sutherland dated August 2012.




November 2012                                         Cardno                                                      17

Used in these records

About this file

File size
37.5 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Part 5 of 37 Appendix 3 - Civil Engineer Report MCU12_0208.pdf · 37.5 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.