Skip to the record
Accept no substitutions.

Council archive · source document

Part 5 of 37 Appendix 3 - Civil Engineer Report MCU12/0208

of 50

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

Very large file (37.5 MB): the whole original can take several minutes to open, especially on a phone. Text is quick to read.

Original PDF page 44, section 1. The text section number identifies this passage in the reader.

Our Ref      B024_5101_L01 PL.docx

Contact      Paul Lonard
                                                                                                        c..r.., Cardno
                                                                                                                Shaping the Future


28 August 2012                                                                                                  Cardno (Qld)Pty Ltd
                                                                                                                ABN 57 051 074992




Mr Warren Steiner
                                                                                                                Level 11
PO Box 4480                                                                                                     515 St Paul’s Terrace
Springfield OLD 4300                                                                                             Fortitude Valley OLD 4006
                                                                                                                Australia


                                                                                                                Locked Bag 4006
                                                                                                                 Fortitude Valley OLD 4006
                                                                                                                Australia

Dear Warren
                                                                                                                Phone: 61 7 3369 9822
                                                                                                                 Fax:       61 733699722

NOOSA ON WEYBA
                                                                                                                www.cardno.com.au
PRELIMINARY                  ROAD                TRAFFIC            NOISE         ASSESSMENT   -   PRE-DESIGN
CONSTRAINTS


A   preliminary analysis was conducted to determine the impact of road traffic noise from Walter Hay
Drive at the proposed Noosa on Weyba residential subdivision. The results and conclusions drawn from
this analysis are based upon a number of assumptions.


Model Assumptions
The preliminary analysis was based on the following assumptions:


.         Current traffic projections from Cardno (Traffic and Transport) for the year 2024, including the
          development traffic contribution.
.         Flat topography and no natural screening features.
.         3% grade on Walter Hay Drive (note that a steeper road is typically louder)
.         Speed zones as shown on the attached noise level contours (Figures 1-3, attached);
.         A dwelling setback of 5m for front and back boundaries, with a 1 m setback on side boundaries;
.         Noise limits for the site will be the same as those detailed in the joint experts’ report for the
          neighbouring lot to the south.
.         The maximum internal noise limits from AS2107 would apply;


The accuracy of the traffic noise model has not been verified against measured data. Noise
measurements will usually adjust noise models by :!::2 dB(A); however variations in rare cases can be
higher than :!::5 dB(A). This is usually due to the road surface, or atypical traffic conditions (e.g.traffic
lights).

Results Summary
Taking into consideration the model assumptions, SoundPLAN generated noise level contours at 1.8m
above ground level (Figure 1, attached) and 4.6m above ground level (Figure 2, attached). The results
shown in these figures can be summarised as follows:


.         The green contour represents a predicted traffic noise level of 63 dB(A) L1O, 18hour. Locations
          where building envelopes or recreational areas fall between this contour and the road reserve are
          considered to be traffic noise affected. Those outside the contour, are not traffic noise affected.
.         Future buildings on traffic noise affected building envelopes (at ground floor and above) are likely
          to require acoustic treatment to achieve the internal noise limits specified in the relevant
          Australian Standard (AS2107).
.         Future recreation areas impacted at levels above 63 dB(A)will require screening to achieve
          compliance. Barrier and building screening at this point in time are both considered options;
          however road front lots on the eastern side will most likely require barriers.



K:\OO_Acoustics\BOOX Projects\B024   -
                                         Noosa on Weyba\B024_51 OI_LO I PL.docx

Used in these records

About this file

File size
37.5 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Part 5 of 37 Appendix 3 - Civil Engineer Report MCU12_0208.pdf · 37.5 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.