DRAWING SIZE — A3
FINISHED
ACCORDANCE WITH CONSTRUCTION
HYDRAULICS CONSULTANTS
DOCUMENTATION.
~ NOV
‘
s
GROUND.
1200{L) 50 Sq. HDHD SPIKES,
1800 ctrs DRIVE 600 INTO
GROUND.
7411/2007 10:10:42 AM, 1:0.960279
RECEIVED
TOGSA SHIRE CCUNCIE
eo FRONT COUNTER
9 “e->
- \
900(H)-GE6—FABRIC SILT--
FENCE, FIXED 10 SPIKES AND
BURIED 300 INTO STABLE
SITE DRAINAGE IN
RP BOUNDARY _
2007
THE USE OF
FENCE MST
LANDSCAPING
RUNOFF FROM MTHN THE ALLLOTMENT MUST ORAN TOWARDS THE SITE PLAN
a FENee AD SLL NOT EER BOURNG AROTUNTS THROUGH cole 1.
SURFACE BUNDING OR SCOUR PROTECTED DRAINS. THE
REMAIN IN PLACE UNTIL SUCH TIME THAT FINISHED
AND DRAINAGE MEASURES ARE INSTALLED
_o
=
LEGEND
~ INDICATES EXISTING SURFACE
CONTOUR AND LEVEL TO AHD.
~—=+- SILT RETENTION FENCE TO DETAIL
DRIVEWAY CROSS OVER DETAILS
TO BE IN ACCORDANCE WITH
NOOSA SHIRE COUNCIL'S STD
DRAWINGS 9005 & 9019.
GRANT STREET
CREATE BUNDING IN
TEMPORARY HARDSTAND
a FOR DIVERISION INTO
SILT FENCE.
20-40mm AGGREGATE
HARD STAND OVERLAY
FOR DRIVE WAYS DURING
CONSTRUCTION.
GENERAL:
4. Do not scale from this drawing.
2. All dimensions in millimetres
3. Setting out dimensions are to be obtained from the architectural drawings.
4, Any discrepancies between these drawing and the architectural drawings are to
be referred to the engineer immediately.
5, The builder is responsible for locating all existing services within and adjacent
the allotment and shall ensure that all new works are in accordance with the
attached critical depth line diagram.
FOOTPATHS AND DRIVEWAYS:
1. Existing footpaths to be sow cut prior to removal
2. Crossings are not designed for commercial vehicles
3. Concrete driveway to be 125mm thk. excluding any finished treatments, eg.
stamping
4. Concrete surface tolerance +5.0mm over 3.0m
5. Concrete N25 in accordance with AS 1379 ond AS 3600
6. Reinforcement fabric to AS 1304, placed central slab depth.
7. Expansion joints to be 10mm wide wet tooled with every 2nd mesh wire cut
along joint.
8. For curved driveways, maximum grades opply to inside edge of curve
9. All services to be located ond protected as required prior to work commencing
FILLING NOTES:
—The site is to be scraped clear of all organic materiol and debris.
= The subgrade is to be proof rolled with o vibrating steel drum roller to achieve
© minimum relotive field density of 95% The compaction is to be sufficient to
achieve o blow count of 7 blows per 300mm with on approved Perth Sand
Penetrometer for a depth of 1.0m below excavated level. Copies of compaction
test results shall be presented to SCG Consulting Engineers for opproval.
= Upon the written approval of the subgrade preperations by SCG Consulting
Engineers
the allotment is to be filled to the specified levels,
= The fill material clean granular material (i.e. sond to @ clayey sond in
accordance with ASI726) be free of any organic material and hove a clay
content of less then 12% (Plosticity index less than 25% Linear shrinkage of
15%). The proposed material is to be inspected by SCG Consulting Engineers prior
to its removal to ensure its compatability.
- The fill is to be placed ond compacted in accordance with AS3798-1996 to a
level sufficient to achieve o Level 1 certification with o minimum relative field
density of 95% Copies of compaction test results shall be presented to SCG
Consulting Engineers for approval.
— Filling and compacting adjacent exisiting structures is to be in strict
accordance with the associated details and specifcations.
= Areas where existing structures or trees are removed shall be backfilled with
the approved fill material compacted in accordance with AS2870-1996 to achieve
© minimum relative field density of 95%
~ Any loose or soft material uncovered in the site preparation shall be removed
and replaced with the approved fill material compacted in accordance with
AS2B70--1996 to achieve o minimum relative field density of 95%
= Site drainage and sit protection measures must be istalled prior to
construction commencing.
(CONSULTING ENGINEERS {
SCG structural - civil - geotechnical ES
ABN 40 098 481 899
18 DUKE STREET SUNSHINE BEACH QLD.4567
Ph (07) 5447 5544 Fax (07) 5447 2634
Title: Operational Works Plan
Project Lot 9 & 10 Grant Street
Noosaville QLD 4566
‘| Date: Sept 2007 Drg No.17320-OWP-2
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/1993 - Response to Information Request [As Published]Related documentApplication case desk ↗
About this file
- File size
- 632 KB (small file)
- File type
No other editions are linked here.