203 AS/NZS 3000:2018 STREET LIGHTING CERTIFICATE LEGEND
AN
EL
3.11.5 Spacing from other underground services SYMBOL DESCRIPTION
RS
ROAD AND PUBLIC SPACE LIGHTING IS CERTIFIED
HO
All underground wiring systems shall be spacing not less than 100 mm from TO COMPLY WITH THE NOMINATED CATEGORIES OF
1 STATION NUMBER
AS/NZS 1158.1.1:2005 AND AS/NZS 1158.3.1:2005.
CE
other underground services. EXISTING OH CONDUCTOR
RA
NEW STREET 1 - PR5 PROPOSED OH CONDUCTOR
Wiring systems shall be suitably marked with warning tape in accordance NEW STREET 2 - PR5 HV and LV POLE
with Clause 3.11.4.5 and maintain a separation from telecommunications, LAKE MACDONALD DRIVE - V4 POLE TRANSFORMER
gas and water services in accordance with Table 3.7.
HV AIR BREAK OPEN
SHEET 4 SHEET 3 THE DESIGN ASSUMES MAINTENANCE FACTORS OF
0.7 FOR MINOR ROAD LIGHTING, 0.75 FOR MAJOR HV AIR BREAK CLOSED
Further requirements for the separation of telecommunications, gas and
SHEET 2 water systems from low voltage wiring systems are provided in ROAD LIGHTING, 0.75 FOR LED LIGHTING, BASED ON
THE FOLLOWING SCHEDULE.
LV DISC LINK OPEN
LV DISC LINK CLOSED
Clause 3.9.8.4.
HV POLE TERMINATION
TABLE 3.7 1. LAMPS ARE TO BE REPLACED AT 36 MONTH LV POLE TERMINATION
INTERVALS, AT WHICH TIME LUMINAIRES ARE TO
MINIMUM SEPARATION OF UNDERGROUND SERVICES GROUND STAY
BE INSPECTED, CLEANED AND MAINTAINED.
2. VEGETATION IS TO BE KEPT CLEAR OF STREET EXISTING UG CABLE
Minimum separation to low Minimum separation LIGHTS. PROPOSED UG CABLE
voltage electrical service of conductive 3. INSPECTION PATROLS AND SPOT LAMP EXISTING SUPPLY PILLAR
NEW identified in accordance with enclosures to low
STR REPLACEMENT SHALL MAINTAIN SERVICE PROPOSED SUPPLY PILLAR
EET Type of service Clause 3.11.4.5 and mechanically voltage electrical AVAILABILITY AT NOT LESS THAN 95%.
2 LINK PILLAR
protected (1) earthing electrode (1) 4. LUMINAIRES AND LAMPS SHALL BE REPLACED
WITH EXACT EQUIVALENTS. PADMOUNTED TRANSFORMER
mm mm
EXISTING CABLE IN CONDUIT
Water service not PROPOSED CABLE IN CONDUIT
100 500
greater than DN65 (2)
MEN (EARTH GROUND STAKE)
Water service greater E ELECTRICAL CABLE MARKER
300 500 RESIDENTIAL AND
than DN65 (2) CUSTOMER SWITCHBOARD
COMMERCIAL / INDUSTRIAL
E
Sanitary drainage 100 500 PIT
RIV
Stormwater drainage 100 600
SUBDIVISIONS S70 STREET LIGHT
DD
CFL 32 STREET LIGHT
Gas 100 500 ONLY ENERGEX APPROVED MATERIALS,
AL
TREE
INSTALLATION EQUIPMENT, AND
ON
Telecommunications 100
INSTALLATION TECHNIQUES SHALL BE
LV SWITCH FUSE UNIT
D
USED DURING CONSTRUCTION.
AC
NOTES:
1 Authorities, such as water and as suppliers and electricity distributors, may
M
require their services to be spaced at a greater distance from underground wiring
KE
systems. Also see Figure 3.10. GENERAL NOTES
LA
2 DN = internal diameter of pipe.
1. ALL CABLES TO BE INSTALLED IN CONDUIT WITHIN THE
STANDARD ELECTRICITY ALIGNMENT OF 250-900mm FROM
PROPERTY BOUNDARY.
HORIZONTAL DIRECTIONAL DRILLING 2. CONSTRUCTION PERSONNEL SHALL MEASURE ACTUAL
CABLE LENGTHS REQUIRED ON SITE AFTER INSTALLATION
CONTRACTOR TO INSTALL DRAW ROPES IN ALL CONDUITS
OF CONDUITS THEN NOTIFY SUPPLIER WHEN CONFIRMING
KENSIN AND PLUG. ENSURE THAT CONDUITS ARE INSTALLED AT THE
G CABLE ORDER.
TON CORRECT DEPTH AT THE BEGINNING & END OF CONDUIT RUN.
DR 3. ALL BENDS INSTALLED ON 125mm RETICULATION
SUPPLY ADAPTORS.
CONDUITS MUST BE 1830mm RADIUS UNLESS OTHERWISE
PLAN REGISTER
IV
SPECIFIED.
E
CONSTRUCTION NOTES 4. CONTRACTOR TO SUPPLY ALL LABELS AND SITE ID
DWG No. DWG TITLE NUMBERS TO ENERGEX SPECIFICATION.
1. CONTRACTOR TO INCLUDED PROVISIONAL SUM FOR 5. ELECTRICAL CONTRACTOR TO SUPPLY AND INSTALL
SHEET 7 AC0651-001 COVER SHEET & SURVEY PLAN VACUUM EXCAVATION AS U.G. SERVICES HAVE BEEN CONDUITS AS SHOWN IN CIVIL WORK SCHEDULE.
AC0651-002 ELECTRICAL DESIGN PLAN 1 OF 6 IDENTIFIED IN THE VICINITY. 6. INSTALL ELECTRICAL CONDUIT AND
SHEET 5 AC0651-003 ELECTRICAL DESIGN PLAN 2 OF 6
2. CONTRACTOR INCLUDE PROVISIONAL SUM FOR 'CUT AND
REINSTATE' CONCRETE FOOTPATH, FULL PANEL AND FILL
TELECOMMUNICATIONS PIT AND PIPE IN JOINT USE
TRENCH - REFER PROJECT NUMBER AC1011-T
AC0651-004 ELECTRICAL DESIGN PLAN 3 OF 6 WIDTH.
3. STATIONS 23-23: VEGETATION CLEARING REQUIRED.
AC0651-005 ELECTRICAL DESIGN PLAN 4 OF 6
STEEP INCLINES AND DECLINES PRESENT. CIVIL STANDARDS AND SPECIFICATIONS
AC0651-006 ELECTRICAL DESIGN PLAN 5 OF 6 CONTRACTOR TO PROVIDE CLEAR TRENCH AND LEVEL
AC0651-007 ELECTRICAL DESIGN PLAN 6 OF 6 GROUND FOR PILLAR POSITIONS.
THIS WORKS PLAN IS TO BE READ IN CONJUNCTION AND
4. STATIONS 25-26: SHALLOW CONDUIT INSTALLATION
AC0651-008 LV GEOGRAPHIC SCHEMATIC 1 OF 2 COMPLY WITH THE FOLLOWING ENERGEX MANUALS AND
REQUIRED. DIRECTIONAL DRILL NOT APPROPRIATE; OPEN
SPECIFICATIONS:
AC0651-009 LV GEOGRAPHIC SCHEMATIC 2 OF 2 CUT ROAD TRENCH. SEE SHEET 6 FOR ENERGEX
- UNDERGROUND DISTRIBUTION CONSTRUCTION MANUAL
CROSS-SECTION DETAIL.
AC0651-010 HV GEOGRAPHIC SCHEMATIC - OVERHEAD CONSTRUCTION MANUAL
5. TRAFFIC CONTROL REQUIRED.
- PUBLIC LIGHTING MANUAL
AC0651-ENG1 ISOLUX PLOT 1 OF 2 - NETWORK LABELLING AND SIGNAGE MANUAL
AC0651-ENG2 ISOLUX PLOT 2 OF 2 CONSTRUCTION NOTES - PRIVATE
FOR DETAILS OF ADDITIONAL TRENCH CROSS-SECTIONS,
PROPERTY REFER TO ENERGEX UNDERGROUND DISTRIBUTION
CONSTRUCTION MANUAL.
THE CONTRACTOR WILL BE RESPONSIBLE FOR THE FOLLOWING:
· SUPERVISE INSTALLATION OF CONDUITS THE FULL LENGTH OF
THE DRIVEWAY.
UG SERVICES INFORMATION
UNDERGROUND SERVICES SHOWN ON THIS WORKS PLAN
IN THE VICINITY OF PROPOSED EXCAVATION WORKS ARE
INDICATIVE ONLY.
T1
WORK SITE
EE
CONSTRUCTION PERSONNEL SHALL REQUEST ON-SITE
E
AN
EL
IDENTIFICATION AND LOCATION OF EXISTING BURIED
STR
O RS
EH
C
RA
CORDW SERVICES FROM THE QUEENSLAND DIAL BEFORE YOU DIG
OOD DR SERVICE. PH:1100 FAX:1300 652 077 (A MINIMUM OF TWO DAYS
IVE
W
NOTICE IS REQUIRED)
NE
NEW
STRE
REFER JOB No: 19158936.
SHEET 6
ET 2
IVE
DR
D
AL
ON
MA SON RY
D
AC
EM
CONDUIT CROSS SECTION - FOOTPATH & ROADWAY
K
LA
FAL
KENSIN
GTO
ND
R
IV
CO
E
SW
IVE
NC
600 FOOTPATH
DR
IF
STR
RT
T
750 MINOR ROAD
LD
RE
DR
A 1200 MAJOR ROAD
OU
N
E
IV
SC
DO
ET
EC
E
AC
E
T1
NT
EE
M
TR
GE
CORDWO
WS
OD DRIVE
KE DETAIL O DETAIL D DETAIL P DETAIL E
NE
LA
WIL
MA SON RY
FAL
CO
SW
E
IV
NC
DR
IF
STR
RT
T
LD
RE
DR
NA
OU
EET
SC
IV
DO
EC
E
AC
E NT
M
GE
E
AK
WIL
L
SURVEY PLAN 600 FOOTPATH
750 MINOR ROAD
1200 MAJOR ROAD
40 0 40 80 120 160 200 METRES
LOCALITY MAP DETAIL J DETAIL V
SCALE 1:2000 AT A1
SCALE 1:10000
NOTE: 5mm PROTECTION COVER STRIP REQUIRED WHEN NOT
IN ALLOCATED ENERGEX UG ALIGNMENT
ISSUE DESCRIPTION DATE AUSPOWER CONNECT IS THE FIRST POINT OF DEVELOPER DETAILS ALIGNMENTS WORKS COORDINATOR - Approved