S4400175 Rev A Sub 125 Lake MacDonald Drive, Lake MacDonald - Electrical
Attached to the e-mail 19553 - 125 Lake Macdonald Drive - Response to information request - OPW20/0051 - Email 2 of 2.
Original PDF page 11, section 1. The text section number identifies this passage in the reader.
P Category Lighting - AS/NZS 1158.3.1:2005
******************************************
Auspower Connect
----------------
I-table Filename: C:\Program Files (x86)\Perfect Lite\2 ENERGY QLD C
IE Tables incl LED Luminaires 20191002\Minor Road\
CIE\StreetLED3 17W 3K AERO R18287.cie
0.14 LUX Job Name: AC1011 - 125 Lake MacDonald Drive, Lake MacDonald
Luminaire Description: StreetLED3 17W 3K Aero R18287 2097.79
P2127463
P2127460 P2127458 Initial Lamp Flux: 2097 lms
16L NEW S Maintenance Factor: 0.7
TREET 10L 5L
2 P2127462 Stores Code:
P2127461 Upcast Angle: 0 degrees
15L 3.5 LUX
13L Arrangement: Single Side
0.14 LUX Offset Distance: 1/4 Road Reserve
0.14 LUX
T2
Upward Waste Light Ratio: .3 %
4L P2127457
Light Source: LED - Light Emitting Diode
EE
0.14 LUX
Luminaire Classification: Not specified
R
0.14 LUX 3.5 LUX
ST
W
Lighting Category: PR5 (Local Area Roads - Tables 2.1 & 2.6)
NE
19L P2127459 Illuminance Criteria: Average Illuminance (Eav) >= 0.50 lx
P2127464 8L (Maintained values) Minimum Illuminance (Eph) >= 0.07 lx
Illuminance Uniformity (Up) <= 10
0.14 LUX
20L Calculation Grid: 20 x 11 points - Figure 3.7 of AS/NZS 1158.2
P2127465
Mounting Maximum Spacing for different
Height Road Reserve Widths
-------- -----------------------------
0.14 LUX
20.1
+-------+
7.5 | 74.5 |
+-------+
E
RIV
Value/s in above table are all in metres.
DD
The table contains maximum spacings which, for the specified luminaire
and lamp combination, provide compliance with the light technical
AL
parameters (LTPs) of Table 2.6 of AS/NZS 1158.3.1:2005.
ON
CD
Refer next page for list of LTP's at compliant maximum spacings.
MA
KE
---------------------------------------------------------------------------
LA
PlePcat - Vers 3.10 (Built: 10/ 4/13) Run: 30/ 3/2020 at 12:33:38
ISOLUX PLOT
20 0 20 40 60 80 100 METRES
SCALE 1:1000 AT A1
ISSUE DESCRIPTION DATE AUSPOWER CONNECT IS THE FIRST POINT OF DEVELOPER DETAILS ALIGNMENTS WORKS COORDINATOR - Approved
APPROVED: AUSPOWER CONNECT
SUBDIVISION - 5 LOTS INTO 16 LOTS AC1011
A ORIGINAL 08/05/2020 CONTACT FOR CONSTRUCTION ENQUIRIES. Auspower Connect Pty Ltd TEATREE PROPERTY PTY LTD ENERGEX OH - PARENT PROJECT NO. - Curtis Consulting Group
Alex Curtis - RPEQ No. 7917 REFER DA: RAL19/0018
PROJECT NO.
MARK BAIN - DIRECTOR ENERGEX UG - LOTS Lots 1 - 16 SCALE: 1:1000
PO Box 531
(07) 5447 4443 STREETLIGHTS 0.7m BOK CANCELLING LOTS Lot 140 MCH978, Lot 2 RP852009, ENERGEX PROJECT NO.
Buddina, QLD 4575
[email protected] NBN - Lot 3 RP137375, lot 8 RP160703,
Mob 0419 707 166
[email protected]
PROJECT MANAGER DETAILS GAS - Lot 101 SP142407 APPROVED DATE: 08/05/2020 ENGINEERING - ISOLUX PLOT
S4400175
TOD CONSULTING PTY LTD HP GAS - D.A RAL19/0018 CHECKED: J McKenna
ABN 74 166 366 883
DOUG REYNOLDS WATER - LOCAL AUTHORITY Noosa Council DESIGNER: S Whittaker
This drawing is the property of Auspower Connect Pty Ltd and 125 Lake MacDonald Drive,
(07) 5449 9600 STORMWATER - UBD REF Map 5 D18 PHONE: 0419 707 166
must not be used, retained or copied without written permission
Lake MacDonald 4563 ISSUE NO. A SHEET 1 OF 2 A1
[email protected] SEWER - PEGGED On Request ISSUE DATE:
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.