Original source · versioned page text
S4400175 Rev A Sub 125 Lake MacDonald Drive, Lake MacDonald - Electrical
Attached to the e-mail 19553 - 125 Lake Macdonald Drive - Response to information request - OPW20/0051 - Email 2 of 2.
Original PDF page 6, section 1. The text section number identifies this passage in the reader.
DESIGN CONTINUES ON
SHEET 7
EMT T
SP248255 U1287902 28 P1287916
EMT U LOT 19
SP248255 SP248255
kerb
of
Back
umen
edge
of bit
rete
Edge
Conc
240
240 AL 4C
AL (
4C LV) EMT C
T
(LV
)
UR
#13 SP229326
CO
LOT 1
RP173883
59
G EE
WIL
U1287901 P1287915
EMT P
#7 SP266743
LOT 7
SP266743
240 #10
240 AL 4C LOT 100
AL (
4C LV) SP142407
(LV
)
rb
umen
of ke
of bit
Back
Edge
en
bitum
of
eline
en
Centr
bitum
edge
of
rete
Edge
Conc
48
EMT L
SP266743
#6
LOT 6
SP266743
240 U1324294
240 AL 4C
AL (
4C LV)
(LV
)
#5
LOT 5
27
SP266743
P1446131
16 Cu 2C
EMT H
SP266743
15
(SL)
U1324293 27 16
8 Cu
26 2C
(S
DANGER - STN 24-27
L)
12
P1446130 HANDSINK
L 4 (S )
V
C ( L)
24 Cu C (L
)
LV
V)
240 AL 4C (L
0 A 2C
16 AL 4
V) FULL DEPTH & FULL WIDTH MAJOR
E
240 AL 4C (L PLANT IN VICINITY
)
0
kV
24
46
( 11 450mm MIN & FULL WIDTH
.75 #XX
- 7/3 179 LOT 900
TO LOCATE U/G NBN SERVICES
3 TO LOCATE U/G WATER MAIN
SP176968
TO LOCATE U/G SEWER MAIN
P1446128 TO LOCATE U/G STORM WATER SERVICES
TO LOCATE U/G ELECTRICAL MAIN
E P1446129
CAUTION ARRANGE FOR LOCATIONS PRIOR TO ANY
EXCAVATIONS
LIVE LV CABLES 25 U1446119 2C (S
L)
u
16 C
24
DIA
33
SC1446100
NE
315kVA
54
LLA
CO
EMT A
45
24 0 A
SP176968
24
UR
0A L4
)
(LV
L3 C(
C
T
L4 U1446118
A
C LV
240 #1
18
(1 )
1k
LOT 105 LOT 1
V)
240
SP118458 AL SP176968
4C
(LV
)
SITE PLAN
10 0 10 20 30 40 50 METRES
SCALE 1:500 AT A1
ISSUE DESCRIPTION DATE AUSPOWER CONNECT IS THE FIRST POINT OF DEVELOPER DETAILS ALIGNMENTS WORKS COORDINATOR - Approved
APPROVED: AUSPOWER CONNECT
SUBDIVISION - 5 LOTS INTO 16 LOTS AC1011
A ORIGINAL 08/05/2020 CONTACT FOR CONSTRUCTION ENQUIRIES. Auspower Connect Pty Ltd TEATREE PROPERTY PTY LTD ENERGEX OH 3.0m PARENT PROJECT NO. - Curtis Consulting Group
Alex Curtis - RPEQ No. 7917 REFER DA: RAL19/0018
PROJECT NO.
MARK BAIN - DIRECTOR ENERGEX UG 0 - 0.9m LOTS Lots 1 - 16 SCALE: 1:500
PO Box 531
(07) 5447 4443 STREETLIGHTS 0.7m BOK CANCELLING LOTS Lot 140 MCH978, Lot 2 RP852009, ELECTRICAL RETICULATION ENERGEX PROJECT NO.
Buddina, QLD 4575
[email protected] NBN REFER DBYD Lot 3 RP137375, lot 8 RP160703, INSTALL 100kVA POLE TRANSFORMER,
Mob 0419 707 166
[email protected]
PROJECT MANAGER DETAILS GAS - Lot 101 SP142407 APPROVED DATE: 08/05/2020 942m 240mm² AL 4C UG, 18x PILLARS
AND 11x RATE 2 LED STREET LIGHTS
S4400175
TOD CONSULTING PTY LTD HP GAS - D.A RAL19/0018 CHECKED: J McKenna
ABN 74 166 366 883
DOUG REYNOLDS WATER REFER DBYD LOCAL AUTHORITY Noosa Council DESIGNER: S Whittaker
This drawing is the property of Auspower Connect Pty Ltd and 125 Lake MacDonald Drive,
(07) 5449 9600 STORMWATER REFER DBYD UBD REF Map 5 D18 PHONE: 0419 707 166
must not be used, retained or copied without written permission
Lake MacDonald 4563 ISSUE NO. A SHEET 6 OF 10 A1
[email protected] SEWER REFER DBYD PEGGED On Request ISSUE DATE:
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.