SUPERSEDED Approved Plans REC170002 MCU170004 OPW170005 · MCU17/0004
Plans and drawings: the text below has words only, no drawings.
-
NOOSA COUNCIL
APPROVED PLAN
REC17/0002, MCU17/0004,
OPW17/0005
27 APR 2017
ELIZABETH STREET
BM: NAIL IN KERB
RL: 1.600
43
1. 47
57
1. .40
1. .35
57
5
58 4
61
1.
51 1.5
1. 1.4
48
54
1.
1.
1.
PP
1
1
PP
59
1. .55
1.
54
56
50
54
1
1.
1.
1.
1.
40
55
WM
1.
1.
WM
66
54
1.
03
1.
58
20.92 20.92
58
2.
1.
59
4
1.
6
1.
1.
COMMON PROPERTY
94
1.
66
1.
RP78252 17.10
2
74
2 STOREY
1.
BRICK UNITS
35.46
GTP395
3
9
67
5
1.
1.
6.09 7 2
66
1.
77
742m²
1.
1.
SHED
2
35.46
630m²
SINGLE STOREY GTP156216
68
5
1.73
1. 1.
TIMBER & FIBRO
18.36
DECK
IO
MH
LL: 1.53 CP
49
1.
IL: 0.52 5
50
47
6
1.
1.
1.
14.83 20.92
60
1.
SINGLE STOREY4 RP72986
DECK 2 STOREY
BLOCK & H'PLANK
6 GTP671
BLOCK UNITS
Issue:
Unit 1/11 Project Ave,
Noosa Heads
Ph (07) 5455 5604
DEBUILD T/A
email:[email protected]
web:www.scg-engineers.com
ABN 40 098 481 899
Title:
Project
Date: Drawn
Checked: Drg No. Rev.
Rev. - 10.06.16
[OCR of page images]
DRAWING SIZE — Al
LOTS 2 & 3 ON RP 78252
Level Datum AHD
N Level Origin PM 56277, RL 1.635m
&
THIS FOOTING IS FOUNDED Xa | |
BELOW CRITICAL DEPTH
UNE AND IS STABLE.
PIERS OR UNDERPINNING FOUNDED LN
BELOW THE CRITICAL DEPTH LINE
WOULD BE NEEDED 10 SUPPORT
ANY FOOTING THAT IS FOUNDED
ABOVE THE CRITICAL DEPTH LINE.
CRITICAL DEPTH LINE
www.dialbeforeyoudig.com.au
SAY DIAL 1100
"Wy BEFORE YOU DIG
\ 1B
N
. fers
Horizontal 30_Degtees\\
REFER DRG OW4 FOR
SEWER PROTECTION
DETAILS
EXISTING STRUCTURE /DWELLING
INCLUDING NEIGHBOURING
ALLOTMENTS
THE BUILDER/CONTRACTOR
SHALL CONFIRM ALL
RELEVANT LEVELS PRIOR 10
COMMENCING WORKS.
Ups UNSTABLE O ae THIS FOOTING WITHOUT
PIERS IS FOUNDED
ABOVE CRITICAL DEPTH
LINE AND IS UNSTABLE.
LINE OF PROPOSED TRENCH
~~ EXCAVATION. OR EXISTING
SERVICES TRENCH
NOTE:
THIS DETAIL ALSO APPLIES TO EXISTING FOUNDATIONS
ON NEIGHBOURING PROPERTIES. SHEET PILING MUST
BE INSTALLED WHERE EXISTING FOOTINGS WILL BE
FOUNDED ABOVE ANY EXCAVATION CRITICAL DEPTH
LINE
NOOSA COUNCIL
APPROVED PLAN
REC17/0002, MCU1 7/0004,
OPW17/0005
27 APR 2017
BM: NAIL IN KERB
RL: 1.600
1S © © A A be Ms
PT Qn N LS .
E rr E Se SE RE ee PR E x85 at
S Ne Ne ne Ka) N NM
Ww Rs Ww Ww Ww Ww w—-444—-_ w x? Ww Wa Ww Ww
o RP. BOUNDARY ann.
@ 0.92 TV OT S& \ $ ~
NO FILL D-@ Oe iam RW TYPE | a T \ RUPE Sa, OH
| ma - COMM
| \ —< PROPOSED TIMBER
1 LANDSCAPING WALLS & fl
= | \ ADJACENT PROPOSED Al
: Ss DRIVEWAY IF REQUIRED. N
8252 &|
o | © 2?
= | FILL-1.1m APPROX. FILL| VOLUME 1495m3
| | \x 2¢
| 6 Prion ‘ BR
Ino FILL FILL-1.0m 2g _
& ' Se =| GTP39
8 © oy 2 (— - ——_ - —
6.09 « & “ |
‘S| wy " 742m?
SHED 2 3) | o
630m? z) 6 B
FILL-1.0m > &
REY - s | ° 2G TP156.
RO ] oe ~ FILL-0.1.2m &
ro Ig a
ae ES “
x ! a
a |
cu EX. SMH '
O MH IO SCP | C P
LL: 1.53 2 FILL-0.9
IL: 0.52 eb FILL-0.9m Jo RW TYPE 1 a 9m 8
J 14.83 2R)P9 BOUNDARY
REFER DRG OW4 FOR EX. SCP s |
SEWER PROTECTION
DETAILS A | D STOREY G TE
SINGLE STORE RP72986 | VBLOCK & H'PLANK
SITE PLAN — EARTHWORKS & RW SETOUT
Scale 1: 200
CONTRACTOR TO LOCATE ALL SERVICES PRIOR TO
COMMENCING WORKS ON SITE. ALL SERVICES ARE
TO BE PROTECTED IN ACCORDANCE WITH THE
AUTHORITY RESPONSIBLE FOR THE SERVICE
WITH THE QUEENSLAND MANUAL
PARKING
ALL LINE MARKING TO BE IN ACCORDANCE
OF UNIFORM
TRAFFIC CONTROL DEVICES & A.S 2890.1
PARKING FACILITIES PART 1: OFF-STREET CAR
SW/EX
R.P. BOUNDARY
|
|
1/N12 TOP ——__| —
LEGEND
Ne EXISTING SURFACE SPOT LEVELS.
INDICATES OVERHEAD ELECTRICITY
SUPPLY LINE
INDICATES EXISTING SEWER LINE
INDICATES TELSTRA LINE APPROX
ALIGNMENT, BUILDER TO CONFIRM
EXACT LOCATION PRIOR TO WORKS
INDICATES EXISTING STORMWATER
DRAIN
INDICATES DEPTH OF CUT OR FILL
Fill-1.8m AS NOTED
FILLED LOT
GROUND LEVEL
| °
190 BLOCK — CORE
FILLED N12-400 V & H—*}:} -P
— LAP BARS 500MM.
ALL CORES CLEARED
PROVIDE FULL HT.
MOVEMENT JOINTS AT
8.0M CTRS.
BEFORE POUR VIA
CLEAN-OUT BLOCKS. NN P
GROUND LEVEL
rr
(| ~+———— 200MM FREE DRAINING
450
FOOTING BEAM
BACKFILL WITH AGI PIPE
TO OUTLET.
150 THK HEEL SL82
MESH TOP 40 COVER.
H B
1500 | 1000 ——
1200 | 800
800 | 500
500 | 300
300
SLI1TM TOP & BOTTOM
R6 LIGS AT 900 CTRS
B4.000
(BLOCK
RETAINING WALL — TYPE 1
\. _/ TYPICAL SECTION
7
VERTICAL MEMBERS AS PER
TABLE, 1200 CTRS. RAKE
BACK AT ANGLE SHOWN.
200X50 HORIZONTALS
FOR DEPTHS UP 10 1600
BEYOND USE 200X75.
'H’ REPARHEPAINED
GROUND LEVEL
SS
DBPRAHASSSBEETIRIDD.
1.
| SPOON DRAIN OR SIMILIAR
TO RE-DIVERT STORMWATER.
GEOFABRIC OR SIMILIAR FOR
SILT/FINES RETAENSION.
200X400MM FREE DRAINING
BACKFILL IN GEOFABRIC
~ WRAPPING WITH AGI PIPE TO
OUTLET.
GRADE CONCRETE AWAY
FROM POSTS.
20MPA COMPACTED
CONCRETE.
ALL MEMBERS 10
BE H4 TREATED
HDWD
SLEEPER RETAINING WALL ALTERNATIVE DETAIL.
'H RETAINED | VERTICAL MEMBER | FOOTING DEPTH
(D X B)
600 200 x 75 400
900 200 x 75 900
1200 200 x 100 1200
1600 100 x 200 1500
2000 2/125 x 200 1800
-
VERTICAL |
MEMBER Ol
fann—1__?——)_'m1:100 © Al
1:200 @ A3
CONSTRUCTION NOTES
GENERAL:
1. DO NOT SCALE FROM THIS DRAWING.
2. ALL DIMENSIONS IN MILLIMETRES
3. SETTING OUT DIMENSIONS ARE TO BE OBTAINED FROM THE ARCHITECTURAL
DRAWINGS.
4. ANY DISCREPANCIES BETWEEN THESE DRAWING AND THE ARCHITECTURAL
DRAWINGS ARE TO BE REFERRED TO THE ENGINEER IMMEDIATELY.
5. THE BUILDER IS RESPONSIBLE FOR LOCATING ALL EXISTING SERVICES
WITHIN AND ADJACENT THE ALLOTMENT AND SHALL ENSURE THAT ALL NEW
WORKS ARE IN ACCORDANCE WITH THE ATTACHED CRITICAL DEPTH LINE
DIAGRAM.
FOOTPATHS AND DRIVEWAYS:
1. EXISTING FOOTPATHS TO BE SAW CUT PRIOR TO REMOVAL
2. CROSSINGS ARE NOT DESIGNED FOR COMMERCIAL VEHICLES
3. CONCRETE DRIVEWAY 10 BE 125mm THK. EXCLUDING ANY FINISHED
TREATMENTS, EG. STAMPING
4. CONCRETE SURFACE TOLERANCE +5.0mm OVER 3.0m
5. CONCRETE N25 IN ACCORDANCE WITH AS 1379 AND AS 3600
6. REINFORCEMENT FABRIC TO AS 1304, PLACED CENTRAL SLAB DEPTH.
7. EXPANSION JOINTS TO BE 10mm WIDE WET TOOLED WTH EVERY 2ND MESH
WIRE CUT ALONG JOINT.
8. ONE ACCESS POINT PERMITTED FOR EACH ALLOTMENT.
9. FOR CURVED DRIVEWAYS, MAXIMUM GRADES APPLY TO INSIDE EDGE OF
CURVE
10. ALL SERVICES TO BE LOCATED AND PROTECTED AS REQUIRED PRIOR TO
WORK COMMENCING
FILLING NOTES:
—THE SITE IS TO BE SCRAPED CLEAR OF ALL ORGANIC MATERIAL AND
DEBRIS.
— THE SUBGRADE IS TO BE ROLLED WITH A VIBRATING STEEL DRUM
ROLLER TO ACHIEVE A MINIMUM RELATIVE FIELD DENSITY OF 95%. THE
COMPACTION IS TO BE SUFFICIENT TO ACHIEVE A BLOW COUNT OF 7
BLOWS PER 300mm WITH AN APPROVED PERTH SAND PENETROMETER
FOR A DEPTH OF 1.0m BELOW EXCAVATED LEVEL. COPIES OF
COMPACTION TEST RESULTS SHALL BE PRESENTED TO SCG CONSULTING
ENGINEERS FOR APPROVAL.
— THE FILL MATERIAL CLEAN GRANULAR MATERIAL (I.E. SAND TO A
CLAYEY SAND IN ACCORDANCE WITH AS1726) BE FREE OF ANY
ORGANIC MATERIAL AND HAVE A CLAY CONTENT OF LESS THAN 12%
(PLASTICITY INDEX LESS THAN 25%, LINEAR SHRINKAGE OF 15%). THE
PROPOSED MATERIAL IS TO BE INSPECTED BY SCG CONSULTING
ENGINEERS PRIOR TO ITS REMOVAL TO ENSURE ITS COMPATABILITY.
— THE FILL IS TO BE PLACED AND COMPACTED IN ACCORDANCE WITH
AS3798-1996 TO A LEVEL SUFFICIENT TO ACHIEVE A LEVEL 1
CERTIFICATION WITH A MINIMUM RELATIVE FIELD DENSITY OF 95%.
COPIES OF COMPACTION TEST RESULTS SHALL BE PRESENTED TO SCG
CONSULTING ENGINEERS FOR APPROVAL.
— FILLING AND COMPACTING ADJACENT EXISITING STRUCTURES IS TO BE
IN STRICT ACCORDANCE WITH THE ASSOCIATED DETAILS AND
SPECIFCATIONS.
— AREAS WHERE EXISTING STRUCTURES OR TREES ARE REMOVED SHALL
BE BACKFILLED WITH THE APPROVED FILL MATERIAL COMPACTED IN
ACCORDANCE WITH AS2870-1996 TO ACHIEVE A MINIMUM RELATIVE
FIELD DENSITY OF 95%.
— ANY LOOSE OR SOFT MATERIAL UNCOVERED IN THE SITE
PREPARATION SHALL BE REMOVED AND REPLACED WITH THE APPROVED
FILL MATERIAL COMPACTED IN ACCORDANCE WITH AS2870-1996 TO
ACHIEVE A MINIMUM RELATIVE FIELD DENSITY OF 95%.
— SITE DRAINAGE AND SILT PROTECTION MEASURES MUST BE ISTALLED
PRIOR TO CONSTRUCTION COMMENCING.
KEY
EX. SWPT EXISTING STORMWATER MANHOLE /PIT
EX. SCP EXISTING SEWER CONNECTION POINT
RC. HW. — REINFORCED CONCRETE HEADWALL
EX. SMH — EXISTING SEWER MANHOLE
EX. SWMH EXISTING STORMWATER MANHOLE
SWMH NEW 1050 STORMWATER MANHOLE
E.0.B. EXISTING EDGE OF BITUMEN
K&C EXISTING KERB & CHANNEL
N.S.L. NATURAL SURFACE LEVEL
FH. FIRE HYDRANT
TP TELSTRA PIT
EP. ELECTRICAL POWER POLE
KERB EXISTING KERBING
Revision Description Date
Issue:
FOR APPROVAL
DO NOT SCALE FROM THIS DRAWING
The design and associated details contained on this and associated
drawings are copyright and are not to be used or reproduced without
the written permission of SCG Consulting Engineers.
Unit 1/11 Project Ave,
Noosa Heads
Ph (07) 5455 5604
email:[email protected]
web:www.scg-engineers.com
‘ABN 40 098 481 899
C) St
DEBUILD TA
Title:
OPERATIONAL WORKS:
EARTHWORKS & RW DETAILS
Project
Lots 2 & 3 RP/8252
Elizabeth St, NOOSAVILLE
Drawn
Nov 16 CSK
Date:
26281-OW3
Checked: Drg No. Rev
S| RPEQ 5835
=| _S Richardson
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
SUPERSEDED Approved Plans REC170002 MCU170004 OPW170005.pdfRelated documentApplication case desk ↗
About this file
- File size
- 6.3 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.