                                                                                         2010/627




            property boundary and in accordance with the council planning scheme. These works
            are to be submitted with the associated operational works application.
      26.3 Proposed lot 3 is to be dedicated council open space and is not subject to development
           and therefore sewer services will not be required.
27.   Retaining walls running horizontally to sewer mains are to be 1.5m clear of the sewer.
      Retaining walls crossing the sewer are to be free standing and self supporting for a minimum
      of 1m both sides of the sewer main.
28.   The level of the existing sewer access chamber must be adjusted to suit the proposed finished
      surface levels. Work must be undertaken by Unitywater at the applicants cost.
29.   A minimum clearance of 1.5 metres must be maintained between Unitywater sewers and
      proposed building envelopes, buildings and other structures.
30.   A 3.0 metre wide easement must be provided over all Unitywater sewers located in private
      property. A 4.0 metre wide easement must be provided over Unitywater sewers greater than
      3.0 metres deep (where approved by Unitywater). Easements must be located centrally over
      the main.
31.   Written approval to enter and construct must be obtained from the owners of properties
      through which external sewers will traverse, and be submitted with lodgement of the
      associated development application for Operational Works
32.   Stormwater retention systems and gross pollutant traps must maintain a minimum clearance
      of 1.5 metres from Unitywater water supply and sewerage infrastructure.
33.   Tree plantings must maintain a minimum horizontal clearance of 1.0 metre from Unitywater
      water mains and 1.5 metres from Unitywater sewerage mains. Landscaping plants within
      these clearances must be low growing when mature and suitable Unitywater approved
      varieties.
34.   Construction works undertaken in the vicinity of Unitywater water supply or sewerage
      infrastructure must not adversely affect the integrity of the infrastructure. All costs associated
      with repair, replacement or alteration of infrastructure must be met by the applicant.
35.   Connection to the Unitywater existing water supply and live sewerage system must be
      undertaken by Unitywater at the applicants cost. Please contact Unitywater for quotation.
Infrastructure Policy
36.   The applicant must pay contributions towards trunk infrastructure in accordance with the
      following Planning Scheme Policies and Council Policies:
      (a)   Planning Scheme Policy 12 – Public Open Space Contributions;
      (b)   Planning Scheme Policy 13 – Contributions in Lieu of Off Street Parking;
      (c)   Planning Scheme Policy 16 – Sewerage Headworks Contributions;
      (d)   Planning Scheme Policy 17 – Water Supply Headworks Contributions;
      (e)   Planning Scheme Policy 20 – Pathway Trunk Network Contributions;
      (f)   Council Policy – Rural Roadworks Contributions;
      (g)   Council Policy – Master Drainage Contributions.
37.   For material change of use of premises approvals the contributions must be paid prior to the
      commencement of use, for reconfiguring a lot approval contributions must be paid prior to
      Council approval of the plan of subdivision.
38.   The actual amount of the contribution must be calculated and paid in accordance with the
      Planning Scheme Policies and variations due to indexation current at the time of payment.



                                                                                      Page 5 of 19

Used in these records

About this file

File size
1.3 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

SUPERSEDED Negotiated Decision Notice - 010.2010.00000627.001 [As Published].pdf · 1.3 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.