Skip to the record
For the highest quality transcripts.

Council archive · source document

23643 DA - Change to existing approval [As Published] · 132003.221152.4

of 37

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

@ Page3

4, ASSESSMENT

The Noosa Plan requires any extension to a Detached House located at 6-14 Park Road, Noosa Heads to be
assessed against the provisions of the Detached House Code. This is provided below.

Lala
Trower ed

 

Column 2
eer CR Cty

 

Compliance

 

Setbacks

o1 Buildings and other structures are

appropriately designed and sited to—

a) provide amenity for users of the
premises as well as preserve the
visual and acoustic privacy of
adjoining and nearby land uses;

b) preserve any existing vegetation that
will buffer the proposed building from
adjoining uses;

c) allow for landscaping to be provided
between buildings; and

d) maintain the visual continuity and
pattern of buildings and landscape
elements within the street.

   
 

$1.1 The minimum setback of the
Detached house or dwelling unit and
associated buildings and structures from
boundaries is not less than the minimum
specified in Schedule 1; or

$1.2 Where there is a conflict between
boundary setbacks in Schedule 1, the
greater of the setbacks prevails;

AND
$1.3 If there are no applicable setbacks

shown in Schedule 1, the siting provisions of
Part 11 or 12 of the Queensland

Complies — The proposed extensions
will not reduce the existing setbacks of
the dwelling.

 

adequate safe distance from electrical
infrastructure including substations,
overhead powerlines, power poles and
transformers.

swimming pools, sheds, tennis courts or
outbuildings) are not constructed under
overhead electricity transmission lines, or
within electricity easements.

SBR alternative provision to QDC Parts Develo Code apply.
11 and 12, P1, P2 and P7 SBR alternative provision to QDC Parts
11 and 12, A1, A2and A7
Electricity supply infrastructure
04 Uses and works maintain an $4.1 Buildings and structures (including Not Applicable - No overhead electricity

transmission lines or electricity
easements traverse the site.

 

Landslide hazard areas

OS Detached houses, Ancillary
dwelling units and associated uses are
sited or constructed to maintain the
safety of people and property from the
risk of landslide.

 

 

$5.1 Ifon land identified as a Landslide

Hazard Area on Overlay Maps OM1.3-9.3,

the use does not~

a) involve the removal of vegetation
other than grass from use areas: or

b) _ involve excavating or filling of more
than 50m’ of material (other than
placement of topsoil not exceeding
400mm in depth: or

c) __ involve cut or fill with a vertical depth
of more than 1.5m relative to ground
level; or

d) redirect or impede water flows in an
existing watercourse or stormwater
drain; or

e) _ involve construction of an on-site
effluent disposal system, or

$5.2 Asite specific geo-technical report

prepared by a registered professional

engineer either—

a) certifies that the site is not at risk from
landslide emanating from the site or
from other land; or

b) identifies methods of stabilising all
buildings, accessways and use areas;

AND

$5.3 If the geo-technical report identifies

methods of stabilising buildings,

accessways and use areas, those methods
are implemented.

 

The subject site is located within a
Landslide Hazard Area.

a) Complies - As can be seen on the
proposal plans, no significant on-site
vegetation is required to be removed.
Further, as the proposed extensions are
able to be undertaken without additional
footings, the works will not impact upon
the root systems of existing trees.

b) Complies with Specific Outcome - it
is not proposed to excavate greater than
50m* of material. The elevations
included as Attachment 2 detail the
extent of excavation proposed on site.

¢) Complies - No benching of the site is
proposed.

d) Complies - No watercourses or
stormwater drains traverse the site.

e) Complies - The site is connected to
Council's sewer network,

 

 

Used in these records

About this file

File size
2.1 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

23643 DA - Change to existing approval [As Published].pdf · 2.1 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.