GENERAL NOTES
unit 1 + 2/35 karathina street, noosa heads qld 4567
lot 125 on RP9258
TIMBER FRAMING AND CONSTRUCTION
1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH
THE AUSTRALIAN DOMESTIC BUILDING CODE.
2. ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH
AS 1684.2 2010 RESIDENTIAL TIMBER FRAMING MANUAL.
3. PINE FRAMING TO BE MINIUMUM STRESS GRADE
MGP 10/MGP12
4.HARDWOOD FRAMING TO BE MINIMUM STRESS
GRADE F14 & MINIMUM JOINT GROUP J2.
5. TIMBER FOR TRUSSES TO BE MINIMUM JOINT GROUP JD4.
6. TRUSSES TO BE FIXED IN ACCORDANCE WITH MANUF.
SPECIFICATIONS ALL OTHER FIXINGS TO BE IN
ACCORDANCE WITH AS 1684.2 2010
7.LAMINATED BEAM SIZES BASED ON HYNEBEAM SPAN
UPPER FLOOR TOP PLATE TABLES WHERE OTHER BRANDS ARE USED, SIZES TO
BE CONFIRMED WITH MANUFACTURERS SPECIFICATIONS.
UPPER FLOOR JOINERY LINE 8. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALES
9. BUILDER AND TRADES ARE TO CONFIRM ALL
2630
MEASUREMENTS, DETAILSAND SPECIFICATIONS PRIOR TO
2100
SETOUT AND ORDERING OF MATERIALS
10. ANY ERRORS ARE TO BE ADDRESSED TO THE DESIGNER
AS NO RESPONSIBILITY WILL BE TAKEN AFTER
UPPER FLOOR
CONSTRUCTION HAS COMMENCED
300
TOP PLATE 11. ALL TRADES ARE TO CONFORM WITH THE
JOINERY LINE CURRENT AUSTRALIAN STANDARDS RELATING TO HIS OR
HER OWN WORK
12. TERMITE PROTECTION TO BE PROVIDED AS PER AS
2400
2100 3660.1.2000
FLOOR DOMESTIC SMOKE ALARMS
1. ALL BEDROOMS AND HALLWAYS ARE TO BE INSTALLED
200
PAD LEVEL WITH PHOTO ELECTRIC SMOKE ALARMS IN ACCORDANCE
Elevation A WITH BUILDING FIRE SAFETY LEGISLATION AMENDMENT
REGULATION 2016
2. SMOKE ALARMS MUST BE POSITIONED IN ACCORDANCE
WITH AS 1670.6 - 1997 FIRE DETECTION, WARNING, CONTROL
AND INTERCOM SYSTEMS.
3. DEVICES MUST BE EITHER INTERCONNECTED OR HARD
WIRED (EXISTING DWELLINGS ONLY) THAT CANNOT BE
REMOVED FROM DEVICE
existing propose to build in balcony existing
4. ALARMS TO BE INSTALLED IN ALL HALLWAYS AND
BEDROOMS TO EXISTING RESIDENCES
S INDICATES THE LOCATION OF WIRED SMOKE ALARMS
GLAZING
1. DOOR AND WINDOW SCHEDULE IS INDICATIVE ONLY AND
SUBJECT TO CONFIRMATION UPON SITE MEASURE
2. OBSCURE WINDOW NOTATION REFERENCE ONLY, CLIENT
TO CONFIRM WITH BUILDER AND WINDOW SUPPLIER FOR
PRIVACY OPTIONS
ELECTRICAL AND ENERGY EFFICIENCY
1. ELECTRICALS TO BE CONFIRMED BY OWNER/BUILDER
AND ELECTRICIAN, PROPOSED PLAN IF REQUESTED
INDICATIVE ONLY
DOWNPIPES
ALL LOCATED DOWNPIPES INDICATIVE ONLY AND
CONFIRMED AT TIME OF ROOFING CONSTRUCTION
AND COMPLIANCE
Elevation B
existing elevations
NOT FOR CONSTRUCTION
NOTE: INSTALLATION OF ALL EXTERNAL MATERIALS BY BUILDER AS PER MANUFACTURERS SPECIFICATIONS AND CERTIFICATION REQUIREMENTS AS OUTLINED BY NCC
PROPOSED: CLIENT: HELEN MADDERN BUILDER: CHRISTIAN MANDY'S DESIGN + DRAFTING SHEET: 3 of 6 DATE: ISSUE NO:
BALCONY BUILD IN PH: 0419 296 088 PH: 0422 652 760 QBCC NO: PH: 0403 481 474 QBCC: 15117996 SCALE: 1:100 31 AUG 2026 HM-2026-D
NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION
WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH WITH ENERGY EFFICIENY REPORT
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix A - Amended Design Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.6 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.