Council archive · source document
LVS Capital - Full construction plans · MCU24/0069
Plans and drawings: the text below has words only, no drawings.
M16 S.S BOLT
APPLY SUITABLE SEALANT AROUND
BOLT WHEN FITTING
10mm H.D.P.E CAPPNG PLATE
HOLE IN FLAT BAR DRILLED
AND TAPPED INSITU TO SUIT—1
BOLT
CO
SECTION VIEW
FULLY WELDED TO SLEEVE M16 S,S
L109 X 12 M.S FLAT BAR WELDED
ACROSS TOP OF PILE
12mm — 15mm H.D.P.E SLEEVE
EXTENDS TO 1.5m
BELOW SEA BED
ju STEEL PILE EXTENDS
TO REQUIRED EMBEDMENT
H.D.P.E SLEEVE SHOWN CUT AWAY
STEEL PILE SEALED INSIDE SLEEVE
BOLT SECURING
SLEEVE TO PILE
|
S|
PILE DETAIL
STANDARD H.D.P.E CAPPED
10mm FULLY WELDED CAPPING
M16 S,S BOLT SECURING
SLEEVE TO PILE
PICTORIAL VIEW
PLATE TO TOP OF PILE
PILE DETAIL
STEEL CAPPED AND
H.D.P.E CAPPED
Es EDGE Consulting Engineers}
P.O Box 6148
vse QLD 4102
Ph: +61 7 3367 3570
ABN 66 099 997 985 [email protected]
B SECURING BOLT & CAPPING UPDATED
MA
14/1/19
DESCRIPTION
BY
DATE _|APPD
THE MARINA SPECIALIST
TRADING AS ACN 010633119 18 RON PARKINSON CRES
CORBOUND PARK
1100
CHENT: LVS CAPITAL PTY LTD (SEYMOUR)
LOT 10 (22) NOOSA PDE
NOOSA HEADS
TITLE:
STEEL PILE & H.D.P.E SLEEVE DETAIL
DATE:
THE sett QLD 4551 AUSTRALIA
“7 PHONE(07) 5492 5925 2
=> SPECIALIST
PROJECT:
STANDARD DRAWING
UNITS
‘SCALE:
‘SHEET:
6/11/08 | WM 1:10 1 A3
DRAWN: CHECKED: APPRD: |DRG No: REV:
MA JSP=SC-045 B
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
LVS Capital - Full construction plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.2 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.