6 5 4 3 2 1
REVISION HISTORY
ISSUE FOR APPROVAL APPROVED.................
REV DESCRIPTION BY DATE CHECKED BY
NOT FOR CONSTRUCTION 1 INITIAL RELEASE P.Z. 20/03/2018
NAME................................
ACCESS MANHOLE SIGNED.............................
900 x 900
D DATE........../........../.......... D
A A
INLET OUTLET
TABLE
TANK LID
LID - CLASS D 2.5 t 1.8 t
900 x 900
NOTE:
C PLAN VIEW LIFTING WEIGHTS MAY VARY C
C:\Vault Working Folder\Designs\SPEL\PRODUCTS\FILTER\EMC-45\STANDARD\04 FILTERS\CONCRETE\PROJECTS\SPEL PRECAST T44 TANK 3.7 kL\SP18-SF10170-P.idw
DEPENDING ON CUSTOM DESIGN
ISOMETRIC VIEW
3 OFF
I.D. 1730 SPEL FILTER EMC45
100
900 WEIR BOX
OVERALL HEIGHT 1825
INTERNAL H'T 1525
200
B B
O.D. 1930 100 SIDE VIEW PLAN VIEW
COVER & LID REMOVED FOR CLARITY
SECTION A-A
TOLERANCE: ALL DIMENSIONS 10mm UNLESS OTHERWISE STATED.
CLIENT: DISTRIBUTOR : The drawings must not be disclosed to any thirdDrawn Date PROJECT :
parties without written permission from SPEL Environmental Sydney.
Unauthorised disclosure may result in prosecution. P.Z. 21-03-18
SPEL Environmental - This drawing is the property of SPEL
Environmental ABN: 83 151 832 629 and is subject to return on Check Date
A demand. It is submitted for the use only in connection with the TITLE
SPEL PRECAST TANK A
proposal and contracts of SPEL Environmental with the expressed
Verified Date
conditions that it is not to be reproduced or copied in any form. 3.7 kL CLASS D
This data must only be used in accordance with our standard SF.169D/03-29.CON.300
terms and conditions. 3 SPEL FILTER CARTRIDGES
Copyright Approved Date
SPEL Environmental accepts no responsibility for any loss or SCALE SIZE
N.T.S SHEET REV
damage resulting from any person acting on this information. A3 1 1
The details and dimensions contained in this document may change, Request No.
please check with SPEL Environmental for confirmation of current RN1758 CUSTOMER CODE : DWG No.
specifications. SP18-SF10170-P
6 5 4 3 2 1
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Attachment 4b - Engineering Report Part 2.pdfRelated documentApplication case desk ↗
About this file
- File size
- 15.6 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.