Original source · versioned page text
RECOR Preliminary Stormwater Management Report - 20220198
DRAINS Modelling Results Project number: 20220198 Calculations: B. Parry Street Address: 3 Delorme St Locality: Noosa Heads, NSC Date: 19/08/2022 Pre / Post Comparison (To Delorme St) A.E.P Qy Pre (m3/s) Qy Post (m3/s) Qchange (m3/s) Qchange (%) 63.2% AEP 0.021 0.024 0.003 14% 50% AEP 0.025 0.028 0.003 12% 20% AEP 0.039 0.041 0.002 5% 10% AEP 0.045 0.050 0.005 11% 5% AEP 0.057 0.057 0.000 0% 2% AEP 0.065 0.065 0.000 0% 1% AEP 0.071 0.072 0.001 1% Pre / Post w/ OSD Comparison (To Delorme St) Tank Node Assumptions A.E.P Qy Pre (m3/s) Qy Post (m3/s) Qchange (m3/s) Qchange (%) https://kingspanwatertanks.com.au/product/3000-litre-slimline-tank/ 63.2% AEP 0.021 0.021 0.000 0% 2x3kL slimline tanks 50% AEP 0.025 0.024 -0.001 -4% Total Area 3.5 m² 20% AEP 0.039 0.033 -0.006 -15% Low flow orifice 81 mm 10% AEP 0.045 0.041 -0.004 -9% 57 mm/tank 5% AEP 0.057 0.049 -0.008 -14% Overflow 100 mm 2% AEP 0.065 0.063 -0.002 -3% Tank Height 1.86 m 1% AEP 0.071 0.071 0.000 0% Overlow height 1.76 m