GENERAL NOTES

TO BE READ IN CONJUNCTION WITH ALL DRAWINGS; REFER
TO CONSULTANTS DRAWINGS AND SPECIFICATIONS FOR CO-
ORDINATION OF SERVICES AND EXTENT OF WORKS.

STRUCTURAL DETAILS
REFER TO CONSULTING ENGINEER'S DRAWINGS FOR ALL
STRUCTURAL DETAILS.

DIMENSIONS.
DO NOT SCALE FROM DRAWINGS. GIVEN DIMENSIONS ARE
TO HAVE PRIORITY OVER SCALED DIMENSIONS.

CONSTRUCTION

ALL DESIGN, CONSTRUCTION AND MATERIALS TO BE IN
ACCORDANCE WITH:

AUSTRALIAN STANDARDS;

NATIONAL CONSTRUCTION CODE (NCC);

QUEENSLAND DEVELOPMENT CODE (QDC);

BUILDING REGULATIONS;

MANUFACTURERS SPECIFICATIONS AND INSTALLATION
DETAILS FOR MATERIALS USED.

ALL DESIGN, CONSTRUCTION AND MATERIALS TO BE IN
ACCORDANCE WITH THE NOOSA PLAN SECONDARY
DWELLINGS & ANCILLARY DWELLING UNITS CODE AND MUST
BE WHEELCHAIR ACCESSIBLE

SETOUT

CONTRACTORYBUILDER TO CONFIRM ALL DIMENSIONS,
LEVELS, BOUNDARY LINES AND PEGS ON SITE PRIOR TO.
COMMENCEMENT OF ANY WORK.

SHOULD SITE CONDITIONS DIFFER FROM THOSE INDICATED.
SEEK INSTRUCTIONS FROM THE DESIGNER.

DRAINAGE

ADEQUATE SITE DRAINAGE SHOULD BE INSTALLED TO
ENSURE THAT NATURAL RUNOFF IS DIRECTED AWAY FROM
THE PROPOSED

WALLS AND FOOTINGS. SUBSURFACE DRAINAGE MUST BE
INSTALLED BEHIND RETAINING WALLS TO PREVENT
DEVELOPMENT OF

HYDROSTATIC PRESSURE. SURFACE WATER DRAINAGE TO.
BE IN ACCORDANCE WITH NCC PART 3.1.2.3.

EROSION AND SEDIMENT CONTROL

PROVIDE EROSION AND SEDIMENT CONTROL STRUCTURES,
TO PERIMETER OF WORK AREA AND MAINTAIN IN A
FUNCTIONAL CONDITION AS REQUIRED BY THE LOCAL
AUTHORITY,

BUILDING PLATFORM

PLATFORM IMMEDIATELY SURROUNDING THE BUILDING IS TO.
FALL AWAY FROM FROM THE BUILDING AT A MINIMUM SLOPE
OF 1 IN 20.

CUT AND FILL
CUT AND FILL BATTERS NOT TO EXCEED A MAXIMUM SLOPE
OF 1IN1

ROOF SHEETING

ROOF SHEETING TO BE INSTALLED IN ACCORDANCE WITH
AS1562.1 AND THE MANUFACTURERS SPECIFICATION FOR
THE RELEVANT WIND CLASSIFICATION APPLICABLE TO THE
SITE.

STEELWORK
ALL STEELWORK FITTINGS AND FIXTURES SHALL BE HOT
DIPPED GALVANISED.

TIMBER
ALL WORKMANSHIP AND MATERIALS SHALL BE IN
ACCORDANCE WITH AS1684.2 AND ENGINEER'S DETAILS.

STORE TIMBER 150MM MINIMUM CLEAR OF GROUND, EVENLY
SUPPORTED, WELL VENTILATED AND PROTECTED.

@

GARLAND

proceeding ithe vers,

0 Jasmin Chandler | 0408 866 692
 [email protected]

5
oy
3

 

For engin inom, Engen a
The BildngDesnes craving and reormendatons salt proceence cr acetal aings The
uberis bbe rofed medal, stolen era, dzepnces oot brome apart andro

Copy The dein cantntshon cn his caning rena he prope of GarendDasgn ndispridedrly
fore uce dest Tiscraving nay be copied rhe eles riod rad chargedin any
ayia pr wien ep of ater Das,

USE TIMBERS WITH DURABILITY CLASS AND
PRESERVATIVE TREATMENT SUITED TO INTENDED
APPLICATION AS OUTLINED IN AS 1684.2.

MASONRY
ALL MASONRY CONSTRUCTION TO IN ACCORDANCE
WITH AS3700.

GLAZING

ALL GLAZING TO BE DESIGNED AND INSTALLED IN
ACCORDANCE WITH AS2047 AND AS1288.
MANUFACTURER TO PROVIDE CERTIFICATION ON
COMPLETION.

SHOWERS.
AAA SHOWER ROSES TO BE SUPPLIED IN
ACCORDANCE WITH QDC.

STORM WATER DRAINAGE

STORM WATER DRAINAGE MANAGEMENT SYSTEM TO
BE IN ACCORDANCE WITH AS/NZS 3500,3.2. SURFACE
DRAINAGE TO DISCHARGE EVENLY WITHIN THE SITE
AND WITHOUT NUISANCE TO THE ADJOINING
PROPERTIES.

LIGHTING
ARTIFICIAL LIGHTING MUST BE PROVIDED IN
ACCORDANCE WITH AS1680.

ENERGY EFFICIENT LIGHTING MUST BE 80% MIN OF
THE TOTAL FIXED ARTIFICIAL LIGHTING AS PER QDC.

 

nforson shal tak precedence oer achicha ranings,

  

7 Avocet Pde, Peregian Beach

Mike and Jan Bolton

LANDSCAPING NOTES

MINIMUM DENSITY REQUIRED:
SHRUBS 1.5 METRE CENTRES
SMALL SHRUBS / GROUNDCOVERS 0.5 - 1 METRE CENTRES

USE MATURE PLANTS WHEREVER POSSIBLE; MINIMUM
SIZING REQUIRED:

FEATURE TREES 45LT

STREET TREES 25LT

OTHER TREES 300MM

LARGE SHRUBS 200MM

GROUNDCOVERS 150MM

PREPARATION OF GARDEN BEDS FOR PLANTING:
CULTIVATE EXISTING SOIL IN NATURAL GROUND TO A
MINIMUM DEPTH OF 150MM. IMPORT CLEAN TOPSOIL
(SANDY LOAM) TO A MINIMUM DEPTH OF 300MM,

ABOVE ORIGINAL GROUND LEVEL. ORGANIC MATTER, OR
GYPSUM ETC, MAY ALSO BE ADDED AS NECESSARY

TO IMPROVE THE SOIL FOR THE BEST POSSIBLE GROWTH.
TEST THE SOIL USING A 'SOIL TEST KIT’ TO ENSURE IT IS
HEALTHY AND AMEND AS NECESSARY.

ALL GARDEN BEDS TO BE MOUNDED 300MM MIN

AT CENTRE OF BED, ABOVE FINISHED PAVEMENT

LEVELS, TO PREVENT ANY PONDING AROUND PLANTS.
FERTILIZE USING A SLOW RELEASE FERTILIZER IN ‘PILL’ OR
‘GRANULE’ FORM, AT TIME OF PLANTING, ENSURE THAT
FERTILIZER DOES NOT DIRECTLY CONTACT ROOTS:

MAINTENANCE:

A MAINTENANCE REGIME MUST BE PROGRAMMED TO
MAINTAIN MULCH, WATER, FERTILIZER, PRUNING AND THE
CARE AND/OR REPLACMENT OF ANY DAMAGED OR
DISEASED PLANT.

SHORT TERM:

FOR THE FIRST FOUR WEEKS ALL PLANTS MUST BE
WATERED FOR A MINIMUM OF 20MINS PER DAY
REDUCING TO 10MINS PER DAY FOR FOLLOWING 5
MONTHS (ALWAYS WATER IN RELATION TO RAINFALL).

IRRIGATION

INSTALL AN AUTOMATIC IRRIGATION / DRIP SYSTEM
WITH TIMER TO ALL NEW LAWNS & GARDENS.
PLACE IRRIGATION LINE AFTER PLANTING AND
PRIOR TO MULCHING.

USE ONLY SUN 'HARDENED' PLANTS. ENSURE

HEALTHY ROOT SYSTEM TO ALL PLANTS TO BE USED.
UNDER NO CIRCUMSTANCES ARE ROOT BOUND PLANTS
TO BE USED.

TREES:

ALL 45L TREES AND LARGE SHRUBS WILL NEED TO BE
STAKED SECURELY USING 1800MM STAKES X 2 OR 3
AS NECESSARY AND TIED TO STAKES USIND HESIAN
WEBBING, (TO PREVENT PLANT DAMAGE UNTIL
ESTABLISHED).

MULCH

ALL GARDENS ARE TO BE MULCHED WITH 'PINE BARK'
MULCH TO A MINIMUM DEPTH OF 100MM , TO BE

KEPT 50MM FROM STEMS OF PLANTS TO AVOID COLLAR
ROT.

DRAINAGE:
ENSURE ADEQUATE DRAINAGE IS INSTALLED
BELOW GARDENS AND PAVED AND CONCRETED AREAS.

Date: Rev
ort12018

 

Working Drawings for BA

DRAWING LIST

   

 

SHEET NAME SHEET NUMBER | ISSUE DATE | REVISION

cover ——SSCSC~d TC. z0re
1
Site Plan Wi 1 7 018 1
1
Understorey Landscape Plan WI 4 7. 018 1
07.11.2018 [1
Elevs & Section }WD.2.01 17.11.2018 1
1

7

Perspectives 07.11.2018

 

 

 

 

 

PLANT LEGEND

Bougainvillea Vine

Star Jasmine Vine

 

Variegated Star Jasmine

Dichondra Silver Falls

 

Anthurium
Calathea Prayer Plant

Gardenia Grandiflora Star
Alternanthera Little Ruby

<} nora Prince of Orange

& Bromeliad Sugar Plum

Magnolia Little Gem

 

Hibiscus

 

DEVELOPMENT PERMIT FOR BUILDING WORKS
APPROVED WITH CONDITIONS
Permit No. 8140 Date 11 FEB 2019

This isan approved document. Refer to the Decision
Notice for detals and conditions applying tothe work.
ISSUED BY URBAN CERTIFIERS PTY LTD

 

 

 

 

Title
General

Scale
As
indicated

Issue Date

Notes 07.11.2018

Des Jc
Check:JC

Project #
18.128

Drawing #: Issue
WD.0.02 1

By
fa}
2
ey

 

711112018 10:15:16 PM

 

 

Used in these records

About this file

File size
16.8 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

7 avocet pde.pdf · 16.8 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.