Skip to the record
Accept no imitations.

Original source · versioned page text

Amended Bushfire Risk Assessment and Risk Management Plan

of 38

Page text shows just the words. Original shows the document exactly as it was published.

Plans and drawings

This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).

Log in to see the plans as drawn
                          Ecological Natural Area Management


6.2    Derivation of inputs for assessment of the Potential Bushfire Intensity Class
The assessment of the Potential Bushfire Intensity Class using the protocol of A new methodology
for state-wide mapping of bushfire prone areas (Leonard et al, 2014) requires the following inputs.
Potential Fuel Load
Based on the map of the visually assessed vegetation communities shown in Figure 8, the
Potential Fuel Loads can be derived by relating the assessed vegetation to Queensland State
Planning Policy Natural Hazards, Risk and Resilience Technical Manual.

Table 3: Potential fuel loads for the assessed vegetation communities based on their applicable
potential fuel hazard classes
   Vegetation community                            Vegetation Hazard Class                               Potential fuel load

M quinquinervia woodland                22.2 Melaleuca woodlands on seasonally                               19.7 t/ha
                                           inundated lowland coastal swamps

       Rural residential                40.4 Low grass or tree cover in rural areas                            5 t/ha


Fire Weather Severity
This report will use the specified Forest Fire Danger Index of FFDI 52 as required by Bushfire
Resilient Communities.

6.3    Potential Bushfire Intensity Class for ranges of bushfire fireline intensities
Using the inputs derived above, the Potential Bushfire Intensity Classes for the patches of
vegetation are derived from bands of fireline intensities using the table below.

Table 4: Table of Potential Bushfire Intensity Class derived from Potential Fire line Intensity
             Potential Bushfire Intensity Class                                   Potential Fire-line Intensity
                           Very high                                                      >40,000 kW/m
                              High                                                   20,000 to 40,000 kW/m
                            Medium                                                    4,000 to 20,000 kW/m
                              Low                                                     Less than 4000 kW/m
(Source: Leonard et al, 2014, page 20)




Bushfire Risk Assessment and Management Plan for a small rural subdivision at 15 Jirrama Cr, Cooroibah                  March 2022

                                                               17
Log in to download the original file

Amended Bushfire Risk Assessment and Risk Management Plan.pdf · 5.7 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.