- LEGEND
NOOSA COUNCIL EXISTING TELSTRA UG CABLE
APPROVED PLAN
EXISTING AERIAL CABLE
TELSTRA PLANT IN SHARED UTILITY TRENCH
A OPW22/0104 3 JUN 2022 PROPOSED NBN UNDERGROUND CONDUIT IN
SHARED UTILITY TRENCH A
Service Drop Access Pit
(650mmX280mmX565mm)
S
PROPOSED ENERGEX PILLAR Network Boundary/Local Network Pit (Single Lid)
(700mmX450mmX650mm)
LOCATION. NBN EQUIPMENT TO Distribution/Local Network Connection Pit
CAPPED CONDUIT FOR FUTURE CONNECTION.
BE INSTALLED 900mm MINIMUM (1360mmX555mmX860mm)
S
Fibre Distribution Hub (FDH) Pit
FROM BOUNDARY PEG. (2000mmX555mmX900mm)
RM
Existing Telstra manhole
W
S S
PAVILION STREET
S S Existing Telstra Pit ( 2,3,4,5,6,7,8,9 )
Telstra exchange
Example of Telstra Major Conduit Layout with
RM
9
W
Proposed duct marked to be used by NBN
S
B B
Premise Connection Device (PCD)
FAN
AAAA Fan Access Node site (FAN)
600
W
8
RM
nbn Cable Transition Location
S
7 nbn Network Termination Device
6
X
W W W W W W W W
FH
S X X W Energex Pillar
W
HANSEN PLACE
S
RM
W
S
X W
W W W
SC
W
SV FH
TERMINATE NEW CONDUIT, PLUG AND SEAL
200mm FROM EXISTING PIT.
S
X
S
S
W
S
C S S S S S S
S
X X C
W
W W W W W
X X X X
RM
S
S
W
3 2 1
5 4
S
S
SDU Development Information
10
S
RM
S
W
S
D D
RM
W
S S
S
DO NOT CONSTRUCT
DRIVEWAYS/CROSSOVERS
UNTIL ELECTRICAL WORKS
ARE COMPLETED.
GROUND LEVEL
DEVELOPER TO SUBMIT AS
BUILT DESIGNS TO AMPFLO AT TYPICAL COMMON TRENCH
E E
[email protected] ELECTRICITY AND COMMUNICATION SECTION DETAIL
TO BE PROCESSED BY NBN
BILL OF MATERIAL
NO OF LOTS: 11
NTS
Electricity supply corridor TAPE
Real Property
Trench width as required
Finished Surface
C
PITS DUCTS
Boundary Level SIZE QTY SIZE QTY MTRS
E
2 2 P100 0 0
As Required
5 6 P50 9 331.4
Communication Tape 6 0 P20 10 14
(as required by carrier) 8 0
9 0
TOTAL NUMBER OF PITS: 8
COMMUNICATIONS ENTRY CONDUIT
TOTAL NUMBER OF MANHOLES: 0
Electrical SECTION VIEW TOTAL NUMBER OF CONDUITS: 19
F REAL PROPERTY BOUNDARY Communications Conduits Warning Tape F
(as required) TOTAL LENGTH OF CONDUITS: 345.4
SHARED SERVICE TRENCH ELECTRICAL / COMMS
Protection Cover Strip
as required ALL SERVICE CONDUITS BY CIVIL CONTRACTOR
Pit sand bedding Electrical and communication service conduits to be installed within service
material easement and in compliance with AS/NZ 3000 (SAA Wiring Rules).
TO BE BUILT IN CONJUNCTION WITH
· Electrical service conduit to be minimum 50NB orange heavy duty PVC
· Communications conduit to be P50 white medium duty PVC.
ELECTRICAL RETICULATION A221308
· Protective cover strip to be laid above all service conduits.
G
· All conduits to be installed with draw wire and capped minimum 1 metre PRELIMINARY ISSUE G
COMMS PIT LOCATION DETAIL FOOTPATH ON PUBLIC ROADS within lot being serviced. (NOT FOR CONSTRUCTION)
26/05/2022 1:57 PM
-
STRICTLY N KEY PLAN DRAWING TITLE:
NATIONAL BROADBAND NETWORK
NBNCO APPROVAL RECORD: 10 LOT SUBDIVISION
-
SIGNATURE DATE 25 PAVILION STREET
- DD
WD
MAP1 MAP2 POMONA
- ENABLE#: 317077
AB STATE: QLD REGION: NOOSA
H - H
QUALITY RECORD : SHEET1 FSA: SAM: ADA:
- NBNCO DISCLAIMER
THIS DOCUMENT HAS BEEN PREPARED SOLELY FOR THE USE OF PROJECT No: 221308
- NBNCO LIMITED (ABN 86 136 533 741) FOR USE IN MAINTAINING
NBNCO FACILITIES. IT HAS NOT BEEN CREATED FOR ANY OTHER
ABN 28 111 423 842
Electrical and Telecommunications Consultants
MAP3 MAP4 CADREF No: T221308
A 10/05/2022 S.LYNSKEY PRELIMINARY DESIGN BK USE. IT SHOULD NOT BE SCALED TO LOCATE NBNCO ASSETS. NO
WARRANTY IS GIVEN THAT THE INFORMATION IS ACCURATE OR 07 3372 9280 · [email protected] SCALE SHEET No. REV.
REV DATE DRAFTER DESCRIPTION APPROVED COMPLETE. ampflo.com.au 1 : 500 1 OF 1 A