Skip to the record
Noosa’s premier civic archive.

Original source · versioned page text

35071 plans

of 15

Page text shows just the words. Original shows the document exactly as it was published.

Original PDF page 11, section 1. The text section number identifies this passage in the reader.

Plans and drawings

This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).

Log in to see the plans as drawn
Rendered 75mm foamboard cladding
fixed to manufacturers specification.
                                                                                                                                                        Colorbond Custom orb roof sheeting
                                                                                                                                                        fixed to manufacturers specification
Colorbond Custom orb roof sheeting                                                                                                                      for N3 wind loading. (5° pitch).
fixed to manufacturers specification
for N3 wind loading. (5° pitch).
                                                                                                                                                        Selected Glass balustrade with
                                                                                                                                                        Powder coated Handrail over.
                                                                                                                                                        125mm max. gap. 1000 high.

Scyon Stria 325 Cladding fixed to                                                                                                                       ceiling
manufacturers specification.
                                                                                                                                                                                 head




                                                                                                                                                                         2700
                                                                                                                                                                  2400
Colorbond gutter and fascia
to match roofing. Fix to
manufacturers specification.
                                                                                                                                                        first floor

Timber look aluminium                                                                                                                                   ceiling
framed windows to                                                                                                                                                                head
manufacturers specification.




                                                                                                                                                                         2700
                                                                                                                                                                  2400
                                                                                                                                                        floor

Approx. Existing                                                                                                                                        F.G.L.             225 min.
Ground Line.

Approx. Proposed                                                                                                                                        Nom. 200 thick Pool walls to
Ground Line.                                                                                                                                            engineers specification.

Rendered 250 brick veneer                                                                                                                               Approved Face Fixed Glass Pool
walls in accordance with                                                                                                                                Fence to comply with A.S. 1926.
manufacturers specification.                                                                                                                            Min 1200 high max 100 mm gap.

Rendered 200 series blockwork                                                                                                                           200 series Blockwork walls with with
walls to manufacturers specification.                                                                                                                   select stone finish over to manufacturers
                                                                                                                                                        specification
Decobatten 100x50 Posts
@ 250mm centres to                                                                                                                                      All stairs and balustrades to be in
manufacturers specification.                                                                                                                            accordance with N.C.C. - 2019 Part 3.9.1.
                                                                                                                                                        Balustrades 1000 min. above F.L. with
                                                                                                                                                        125mm max. openings.




                                                                                                                SOUTH ELEVATION
                                                                                                                Scale   1 : 100




                           AK B U I L D I N G D E S I G N
                                                          Dean White & Vivienne Savill                                                             Concept Design 6                            A3
                                                                                                                                  DATE:            29/10/2020
                                                                                                  © Copyright   2 Lakeway Dr.     DRAWING No:
                           T. 07 5443 4200        E. [email protected]
                           A. Suite 9/50 Aerodrome Rd Maroochydore
                                                                        QBCC 1060583      ABN 95 621 039 731
                                                                            P.O. Box 116 Cotton Tree Qld 4558   Cooroibah                       20138A / 402
Log in to download the original file

35071 plans.pdf · 6.4 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.