Appendix F Bushfire Management Plan
Plans and drawings
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn3.0 Bushfire Hazard Assessment 3.1 Bushfire hazard classification Figure 3. Council bushfire hazard mapping “Bushfire Prone Area” (BPA) is defined under Section 12 of Building Regulation 2006 and the BCA as an area identified as such by Local Government , in this case using the methodology specified in A new methodology for State-wide mapping of bushfire prone areas in Queensland (CSIRO 2014). The BCA calls up AS3959- 2018 as providing “Deemed to Satisfy” construction levels for Class 1, 2 and 3 buildings and associated Class 10a structures constructed in bushfire prone areas. AS3959-2018 specifies building implications within 100m of designated bushfire prone land, or more strictly speaking, within 100m of intact, classified vegetation (50m in the case of grassland). This BMP establishes Bushfire Attack Levels (BALs) for affected Lots, using a combination of Methods 1 and 2 approach under AS3959-2018. Report compiled by Bushfire Risk Reducers for Mr K. Courtney, January 2021 Page 8