WORK HEALTH & SAFETY NOTES

THESE WORK HEALTH & SAFETY NOTES MUST BE PROVIDED TO ALL OWNERS, BUILDING CONTRACTORS, SUB-CONTRACTORS, CONSULTANTS, RENOVATORS,
OPERATORS, MAINTENANCE PERSONNEL, DEMOLITION CONTRACTORS, & ALL OTHERS ASSOCIATED WITH PERFORMING WORK ON/OR WITHIN THE BUILDING &
SURROUNDS. THE WORK HEALTH & SAFETY NOTES ARE TO BE FULLY READ & UNDERSTOOD BY ALL PERSONS PRIOR TO COMMENCING ANY WORK.

 

1. FALLS, SLIPS, TRIPS 3. TRAFFIC MANAGEMENT 6. HAZARDOUS SUBSTANCES 8. PUBLIC ACCESS

 

WHEREVER POSSIBLE, COMPONENTS FOR THIS BUILDING SHOULD BE PREFABRICATED
OFF-SITE OR AT GROUND LEVEL TO MINIMISE THE RISK OF WORKERS FALLING MORE
THAN TWO METRES, HOWEVER, CONSTRUCTION OF THIS BUILDING WILL REQUIRE
WORKERS TO BE WORKING AT HEIGHTS WHERE A FALL IN EXCESS OF TWO METRES IS
POSSIBLE & INJURY IS LIKELY TO RESULT FROM SUCH A FALL. THE BUILDER SHOULD
PROVIDE A SUITABLE BARRIER WHEREVER A PERSON IS REQUIRED TO WORK IN A
SITUATION WHERE FALLING MORE THAN TWO METRES IS A POSSIBILITY.

DURING OPERATION OR MAINTENANCE

CLEANING & MAINTENANCE OF WINDOWS, WALLS, ROOF OR OTHER COMPONENTS OF
THIS BUILDING WILL REQUIRE PERSONS TO BE SITUATED WHERE A FALL FROM A HEIGHT
INEXCESS OF TWO METRES IS POSSIBLE. WHERE THIS TYPE OF ACTIVITY IS REQUIRED,
SCAFFOLDING, LADDERS OR TRESTLES SHOULD BE USED IN ACCORDANCE WITH
RELEVANT CODES OF PRACTICE, REGULATIONS OR LEGISLATION. WHERE CLEANING &
MAINTENANCE OF ANY COMPONENTS OFIOR INSTALLATIONS WITHIN THIS BUILDING
MEANS THAT THE USE OF LADDERS OR TRESTLES ARE NOT APPROPRIATE,
SCAFFOLDING, FALL BARRIERS OR PERSONAL PROTECTIVE EQUIPMENT (PPE) SHOULD BE
USED IN ACCORDANCE WITH RELEVANT CODES OF PRACTICE, REGULATIONS &
LEGISLATION, ANCHORAGE POINTS FOR PORTABLE SCAFFOLD OR FALL ARREST DEVICES
ARE TO BE INSTALLED ONITHIN THE BUILDING FOR USE BY MAINTENANCE WORKERS,
ANY PERSONS ENGAGED TO WORK ON THE BUILDING AFTER THE COMPLETION OF
CONSTRUCTION WORK SHOULD BE INFORMED ABOUT THE ANCHORAGE POINTS.

B. SLIPPERY OR UNEVEN SURFACES.

FLOOR FINISHES

SPECIFIED FINISHES MUST BE SELECTED TO MINIMISE THE RISK OF FLOORS & PAVED
AREAS BECOMING SLIPPERY WHEN WET OR WHEN WALKED ON WITH WET SHOESIFEET.
ANY CHANGES TO THE SPECIFIED FINISH SHOULD BE MADE IN CONSULTATION WITH THE
DESIGNER OR, IF THIS IS NOT PRACTICAL, SURFACES WITH AN EQUIVALENT OR BETTER
SLIP RESISTANCE SHOULD BE CHOSEN, THE OWNER IS RESPONSIBLE FOR THE
SELECTION OF SURFACE FINISHES IN THE PEDESTRIAN TRAFFICABLE AREAS OF THIS
BUILDING. SURFACES SHOULD BE SELECTED IN ACCORDANCE WITH AS HB 197:1999 &
‘ASINZ 4586:2004,

STEPS, LOOSE OBJECTS & UNEVEN SURFACES

DUE TO DESIGN RESTRICTIONS FOR THIS BUILDING, STEPS &/OR RAMPS ARE INCLUDED IN
THE BUILDING WHICH MAY BE A HAZARD TO WORKERS CARRYING OBJECTS OR
OTHERWISE OCCUPIED. STEPS SHOULD BE CLEARLY MARKED WITH BOTH VISUAL &
TACTILE WARNINGS DURING CONSTRUCTION, MAINTENANCE, DEMOLITION & AT ALL
TIMES WHEN THE BUILDING OPERATES AS A WORKPLACE. BUILDING OWNERS &
OCCUPIERS SHOULD MONITOR THE PEDESTRIAN ACCESS WAYS & IN PARTICULAR,
ACCESS TO AREAS WHERE MAINTENANCE IS ROUTINELY CARRIED OUT TO ENSURE THAT
SURFACES HAVE NOT MOVED OR CRACKED SO THAT THEY BECOME UNEVEN & PRESENT
ATRIP HAZARD, SPILLS, LOOSE MATERIAL, STRAY OBJECTS OR ANY OTHER MATTER
THAT MAY CAUSE A SLIP OR TRIP HAZARD SHOULD BE CLEANED OR REMOVED FROM
ACCESS WAYS. CONTRACTORS SHOULD BE REQUIRED TO MAINTAIN A TIDY WORK SITE
DURING CONSTRUCTION, MAINTENANCE OR DEMOLITION TO REDUCE THE RISK OF TRIPS
& FALLS IN THE WORKPLACE. MATERIALS FOR CONSTRUCTION OR MAINTENANCE
SHOULD BE STORED IN DESIGNATED AREAS AWAY FROM ACCESS WAYS & WORK AREAS,

2. FALLING OBJECTS

LOOSE MATERIALS OR SMALL OBJECTS

CONSTRUCTION, MAINTENANCE OR DEMOLITION WORK ON OR AROUND THIS BUILDING IS

LIKELY TO INVOLVE PERSONS WORKING ABOVE GROUND LEVEL OR ABOVE FLOOR

LEVELS, WHERE THIS OCCURS ONE OR MORE OF THE FOLLOWING MEASURES SHOULD BE

TAKEN TO AVOID OBJECTS FALLING FROM THE AREA WHERE THE WORK IS BEING

CARRIED OUT OVER PERSONS BELOW,

1. PREVENT OR RESTRICT ACCESS TO AREAS BELOW WHERE THE WORK IS BEING
CARRIED OUT.

2. PROVIDE TOEBOARDS TO SCAFFOLDING OR WORK PLATFORMS.

3, PROVIDE PROTECTIVE STRUCTURES BELOW THE WORK AREA.

4, ENSURE THAT ALL PERSONS BELOW THE WORK AREA HAVE PERSONAL
PROTECTIVE EQUIPMENT

BUILDING COMPONENTS

DURING CONSTRUCTION, RENOVATION OR DEMOLITION OF THIS BUILDING, PARTS OF THE
STRUCTURE INCLUDING FABRICATED STEELWORK, HEAVY PANELS & MANY OTHER
COMPONENTS WILL REMAIN STANDING PRIOR TO OR AFTER SUPPORTING PARTS ARE IN
PLACE, CONTRACTORS SHOULD ENSURE THAT TEMPORARY BRACING OR OTHER
REQUIRED SUPPORT IS IN PLACE AT ALL TIMES WHEN COLLAPSE WHICH MAY INJURE
PERSONS IN THE AREA IS A POSSIBILTY, MECHANICAL LIFTING OF MATERIALS &
COMPONENTS DURING CONSTRUCTION, MAINTENANCE OR DEMOLITION PRESENTS A
RISK OF FALLING OBJECTS. CONTRACTORS SHOULD ENSURE THAT APPROPRIATE LIFTING
DEVICES ARE USED, THAT LOADS ARE PROPERLY SECURED & THAT ACCESS TO AREAS
BELOW THE LOAD IS PREVENTED OR RESTRICTED.

VEHICLES OR LOADINGIUNLOADING OF VEHICLES ON THIS ROADWAY MAY CAUSE A
‘TRAFFIC HAZARD, DURING CONSTRUCTION, MAINTENANCE OR DEMOLITION OF THIS
BUILDING DESIGNATED PARKING FOR WORKERS & LOADING AREAS SHOULD BE
PROVIDED. TRAINED TRAFFIC MANAGEMENT PERSONNEL SHOULD BE RESPONSIBLE FOR
‘THE SUPERVISION OF THESE AREAS.

RESTRICTED ON-SITE LOADING/UN-LOADING

CONSTRUCTION OF THIS BUILDING WILL REQUIRE LOADING & UNLOADING OF MATERIALS
ONTHE ROADWAY. DELIVERIES SHOULD BE WELL PLANNED TO AVOID CONGESTION OF
LOADING AREAS & TRAINED TRAFFIC MANAGEMENT PERSONNEL SHOULD BE USED TO
‘SUPERVISE LOADING/UNLOADING AREAS. BUSY CONSTRUCTION & DEMOLITION SITES
PRESENT A RISK OF COLLISION WHERE DELIVERIES & OTHER TRAFFIC ARE MOVING
WITHIN THE SITE, A TRAFFIC MANAGEMENT PLAN SUPERVISED BY TRAINED TRAFFIC
MANAGEMENT PERSONNEL SHOULD BE ADOPTED FOR THE WORK SITE,

4. SERVICES

RUPTURE OF SERVICES DURING EXCAVATION OR OTHER ACTIVITY CREATES A VARIETY
OF RISKS INCLUDING RELEASE OF HAZARDOUS MATERIAL. EXISTING SERVICES ARE
LOCATED ON OR AROUND THIS SITE, WHERE KNOWN, THESE ARE IDENTIFIED ON THE
PLANS BUT THE EXACT LOCATION & EXTENT OF SERVICES MAY VARY FROM THAT
INDICATED, SERVICES SHOULD BE LOCATED USING AN APPROPRIATE SERVICE ( SUCH
AS DIAL BEFORE YOU DIG ), APPROPRIATE EXCAVATION PRACTICE SHOULD BE USED 8,
WHERE NECESSARY, SPECIALIST CONTRACTORS SHOULD BE USED.

SITES WITH UNDERGROUND POWER

UNDERGROUND POWER LINES ARE LOCATED IN OR AROUND THIS SITE, ALL
UNDERGROUND POWER LINES MUST BE DISCONNECTED OR CAREFULLY LOCATED &
ADEQUATE WARNING SIGNS USED PRIOR TO ANY CONSTRUCTION, MAINTENANCE OR
DEMOLITION COMMENCING.

SITES WITH OVERHEAD POWER LINES

OVERHEAD POWER LINES ARE NEAR OR ON THIS SITE. THESE POSE A RISK OF
ELECTROCUTION IF STRUCK OR APPROACHED BY LIFTING DEVICES OR OTHER PLANT &
PERSONS WORKING ABOVE GROUND LEVEL. WHERE THERE IS A DANGER OF THIS.
OCCURING, POWER LINES SHOULD BE, WHERE PRACTICAL, DISCONNECTED OR
RELOCATED. WHERE THIS IS NOT PRACTICAL ADEQUATE WARNING IN THE FORM OF
BRIGHT COLOURED TAPE OR SIGNAGE SHOULD BE USED OR A PROTECTIVE BARRIER
PROVIDED,

5. MANUAL TASKS

COMPONENTS WITHIN THIS DESIGN WITH A MASS IN EXCESS OF 25KG SHOULD BE LIFTED
BY TWO OR MORE WORKERS OR BY MECHANICAL LIFTING DEVICE, WHERE THIS IS NOT
PRACTICAL, SUPPLIERS OR FABRICATORS SHOULD BE REQUIRED TO LIMIT THE
COMPONENT MASS, ALL MATERIAL PACKAGING, BUILDING & MAINTENANCE COMPONENTS
‘SHOULD CLEARLY SHOW THE TOTAL MASS OF PACKAGES & WHERE PRACTICAL ALL ITEMS
‘SHOULD BE STORED ON SITE IN A WAY WHICH MINIMISES BENDING BEFORE LIFTING.
ADVICE SHOULD BE PROVIDED ON SAFE LIFTING METHODS IN ALL AREAS WHERE LIFTING
MAY OCCUR, CONSTRUCTION, MAINTENANCE & DEMOLITION OF THIS BUILDING WILL
REQUIRE THE USE OF PORTABLE TOOLS & EQUIPMENT. THESE SHOULD BE FULLY
MAINTAINED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS & NOT USED
WHERE FAULTY OR (IN THE CASE OF ELECTRICAL EQUIPMENT ) NOT CARRYING A
CURRENT ELECTRICAL SAFETY TAG, ALL SAFETY GUARDS OR DEVICES SHOULD BE
REGULARLY CHECKED & PERSONAL PROTECTIVE EQUIPMENT SHOULD BE USED IN
ACCORDANCE WITH MANUFACTURER'S SPECIFICATION.

———
‘A. WORKING AT HEIGHTS MAJOR ROAD, NARROW ROAD, OR STEEPLY SLOPING ROAD ASBESTOS IN EXISTING BUILDINGS
DURING CONSTRUCTION WHEREVER POSSIBLE, COMPONENTS FOR THIS BUILDING SHOULD BE PARKING OF BUILDING CONSTRUCTED PRIOR TO 1990

WHEREVER POSSIBLE, COMPONENTS FOR THIS BUILDING SHOULD BE PARKING IF THIS
BUILDING WAS CONSTRUCTED PRIOR TO 1990 & THEREFORE MAY CONTAIN ASBESTOS
EITHER IN CLADDING MATERIAL OR IN FIRE RETARDENT INSULATION MATERIAL. THE
BUILDER SHOULD CHECK 8, IF NECESSARY, TAKE APPROPRIATE ACTION BEFORE
DEMOLISHING, CUTTING, SANDING, DRILLING OR OTHERWISE DISTURBING THE EXISTING
‘STRUCTURE,

BUILDING CONSTRUCTED PRIOR TO 1986

IF THIS BUILDING WAS CONSTRUCTED PRIOR TO 1986 & THEREFORE IS LIKELY TO
CONTAIN ASBESTOS EITHER IN CLADDING MATERIAL OR IN FIRE RETARDENT INSULATION
MATERIAL. THE BUILDER SHOULD CHECK &, IF NECESSARY, TAKE APPROPRIATE ACTION.
BEFORE DEMOLISHING, CUTTING, SANDING, DRILLING OR OTHERWISE DISTURBING THE
EXISTING STRUCTURE

POWDERED MATERIALS

MANY MATERIALS USED IN THE CONSTRUCTION OF THIS BUILDING CAN CAUSE HARM IF
INHALED IN POWDERED FORM. PERSONS WORKING ON OR IN THE BUILDING DURING
CONSTRUCTION, OPERATIONAL MAINTENANCE OR DEMOLITION SHOULD ENSURE GOOD.
VENTILATION & WEAR PERSONAL PROTECTIVE EQUIPMENT INCLUDING PROTECTION
AGAINST INHALATION WHILE USING POWDERED MATERIAL OR WHEN SANDING, DRILLING,
CUTTING OR OTHERWISE DISTURBING OR CREATING POWDERED MATERIAL,

TREATED TIMBER

‘THE DESIGN OF THIS BUILDING INCLUDES PROVISION FOR THE INCLUSION OF TREATED.
TIMBER WITHIN THE STRUCTURE, DUST OR FUMES FROM THIS MATERIAL CAN BE
HARMFUL, PERSONS WORKING ON OR IN THE BUILDING DURING CONSTRUCTION,
OPERATIONAL MAINTENANCE OR DEMOLITION SHOULD ENSURE GOOD VENTILATION &
WEAR PERSONAL PROTECTIVE EQUIPMENT INCLUDING PROTECTION AGAINST
INHALATION OF HARMFUL MATERIAL WHEN SANDING, DRILLING, CUTTING OR USING
‘TREATED TIMBER IN ANY WAY THAT MAY CAUSE HARMFUL MATERIAL TO BE RELEASED.
DO NOT BURN TREATED TIMBER.

VOLATILE ORGANIC COMPOUNDS

MANY TYPES OF GLUE, SOLVENTS, SPRAY PACKS, PAINTS, VARNISHES & SOME CLEANING
MATERIALS HAVE DANGEROUS EMISSIONS. AREAS WHERE THESE ARE USED SHOULD BE
KEPT WELL VENTILATED WHILE THE MATERIAL |S BEING USED & FOR A PERIOD AFTER
INSTALLATION, PERSONAL PROTECTIVE EQUIPMENT MAY ALSO BE REQUIRED. THE
MANUFACTURER'S RECOMMENDATIONS FOR USE MUST BE CAREFULLY CONSIDERED AT
ALL TIMES.

SYNTHETIC MINERAL FIBRES

FIBREGLASS, ROCKWOOL, CERAMIC & OTHER MATERIAL USED FOR THERMAL OR SOUND.
INSULATION MAY CONTAIN SYNTHETIC MINERAL FIBRE WHICH MAY BE HARMFUL IF
INHALED OR IF IT COMES IN CONTACT WITH THE SKIN, EYES OR OTHER SENSITIVE PARTS
OF THE BODY. PERSONAL PROTECTIVE EQUIPMENT INCLUDING PROTECTION AGAINST
INHALATION OF HARMFUL MATERIAL SHOULD BE USED WHEN INSTALLING, REMOVING OR
WORKING NEAR BULK INSULATION MATERIAL.

TIMBER FLOORS

THIS BUILDING CONTAINS TIMBER FLOORS WHICH HAVE AN APPLIED FINISH. AREAS
WHERE FINISHES ARE APPLIED SHOULD BE KEPT WELL VENTILATED DURING SANDING &
APPLICATION, & FOR A PERIOD AFTER INSULATION. PERSONAL PROTECTIVE EQUIPMENT
MAY ALSO BE REQUIRED. THE MANUFACTURER'S RECOMMENDATIONS FOR USE MUST BE
CAREFULLY CONSIDERED AT ALL TIMES.

7 CONFINED SPACES

EXCAVATIONS

CONSTRUCTION OF THIS BUILDING & SOME MAINTENANCE ON THE BUILDING WILL
REQUIRE EXCAVATION & INSTALLATION OF ITEMS WITHIN EXCAVATIONS, WHERE
PRACTICAL, INSTALLATION SHOULD BE CARRIED OUT USING METHODS WHICH DO NOT
REQUIRE WORKERS TO ENTER THE EXCAVATION. WHERE THIS IS NOT PRACTICAL,
ADEQUATE SUPPORT FOR THE EXCAVATED AREA SHOULD BE PROVIDED TO PREVENT
COLLAPSE. WARNING SIGNS & BARRIERS TO PREVENT ACCIDENTAL OR UNAUTHORISED
ACCESS TO ALL EXCAVATIONS SHOULD BE PROVIDED.

ENCLOSED SPACES

ENCLOSED SPACES WITHIN THIS BUILDING MAY PRESENT A RISK TO PERSONS ENTERING
FOR CONSTRUCTION, MAINTENANCE OR ANY OTHER PURPOSE. THE DESIGN
DOCUMENTATION CALLS FOR WARNING SIGNS & BARRIERS TO UNAUTHORISED ACCESS.
‘THESE SHOULD BE MAINTAINED THROUGHOUT THE LIFE OF THE BUILDING, WHERE
WORKERS ARE REQUIRED TO ENTER ENCLOSED SPACES, AIR TESTING EQUIPMENT &
PERSONAL PROTECTIVE EQUIPMENT SHOULD BE PROVIDED.

SMALL SPACES

‘SOME SMALL SPACES WITHIN THIS BUILDING WILL REQUIRE ACCESS BY CONSTRUCTION
OR MAINTENANCE WORKERS, THE DESIGN DOCUMENTATION CALLS FOR WARNING SIGNS
& BARRIERS TO UNAUTHORISED ACCESS, THESE SHOULD BE MAINTAINED THROUGHOUT
THE LIFE OF THE BUILDING, WHERE WORKERS ARE REQUIRED TO ENTER SMALL SPACES
‘THEY SHOULD BE SCHEDULED SO THAT ACCESS IS FOR SHORT PERIODS, MANUAL
LIFTING & OTHER MANUAL ACTIVITY SHOULD BE RESTRICTED IN SMALL SPACES.

 

PUBLIC ACCESS TO CONSTRUCTION & DEMOLITION SITES & TO AREAS UNDER
MAINTENANCE CAUSES RISK TO WORKERS & PUBLIC. WARNING SIGNS & SECURE
BARRIERS TO UNAUTHORISED ACCESS SHOULD BE PROVIDED. WHERE ELECTRICAL
INSTALLATIONS, EXCAVATIONS, PLANT OR LOOSE MATERIALS ARE PRESENT THEY SHOULD
BE SECURED WHEN NOT FULLY SUPERVISED.

9. OPERATIONAL USE OF BUILDING

 

RESIDENTIAL BUILDINGS

WHERE THE BUILDING HAS BEEN DESIGNED AS A RESIDENTIAL BUILDING, & AT A LATER.
DATE IS USED OR INTENDED AS A WORKPLACE, THE PROVISIONS OF THE WORK HEALTH &
SAFETY ACT 2011 OR SUBSEQUENT REPLACEMENT ACT SHOULD BE APPLIED TO THE NEW
USE,

NON-RESIDENTIAL BUILDINGS - END USE UNKNOWN

‘THE BUILDING HAS BEEN DESIGNED TO REQUIREMENTS OF THE CLASSIFICATION
IDENTIFIED ON THE DRAWINGS, THE SPECIFIC USE OF THE BUILDING IS NOT KNOWN AT
‘THE TIME OF THE DESIGN & A FURTHER ASSESSMENT OF THE WORKPLACE HEALTH &
SAFETY ISSUES SHOULD BE UNDERTAKEN AT THE TIME OF FIT-OUT FOR THE END-USER.

NON-RESIDENTIAL BUILDINGS - END USE KNOWN

THIS BUILDING HAS BEEN DESIGNED FOR THE SPECIFIC USE AS IDENTIFIED ON THE
DRAWINGS, WHERE A CHANGE OF USE OCCURS AT A LATER DATE A FURTHER
ASSESSMENT OF THE WORKPLACE HEALTH & SAFETY ISSUES SHOULD BE UNDERTAKEN.

OTHER HIGH RISK ACTIVITY

ALL ELECTRICAL WORK SHOULD BE CARRIED OUT IN ACCORDANCE WITH THE FOLLOWING
CODE OF PRACTICE:

MANAGING ELECTRICAL RISKS AT THE WORKPLACE, ASINZ 3012 & ALL LICENSING
REQUIREMENTS,

‘ALL WORK USING PLANT SHOULD BE CARRIED OUT IN ACCORDANCE WITH THE FOLLOWING
CODE OF PRACTICE:

MANAGING RISKS OF PLANT AT THE WORKPLACE,

ALL WORK SHOULD BE CARRIED OUT IN ACCORDANCE WITH THE FOLLOWING CODE OF
PRACTICE:

MANAGING NOISE & PREVENTING HEARING LOSS AT WORK.

DUE TO THE HISTORY OF SERIOUS INCIDENTS IT IS RECOMMENDED THAT PARTICULAR
CARE BE EXERCISED WHEN UNDERTAKING WORK INVOLVING STEEL CONSTRUCTION &
CONCRETE PLACEMENT, ALL THE ABOVE APPLIES.

 

 

JTC

ow
0
sy
Bq)
OZ ij
ou

 

216130

 

 

 

 

 

T: (07) 5443 6585 3 UEC PIL PROPOSED INDUSTRIAL BUILDING FIGURED DIMENSIONS TO TAKE PRECEDENCE APPROVED
x OVER SCALED MEASUREMENTS. VERIFY ALL ON
F: (07) 5479 1754 8 8 8 EENIE CREEK ROAD SITE DIMENSIONS & LEVELS WITH THE SUPPORTING J JOHN TITMUS
tcengineers.com.au £88 NOOSAVILLE, QLD DOCUMENTATION PRIOR TO THE COMMENCEMENT J RFE £002
inf @jt naineer: m 2 z a A 17/10/2016 | OP WORKS APPROVAL OF ANY CONSTRUCTION. CONTRACTOR TO NOTIFY
[email protected] = Soy JOR DESCRIPTION issue foate | EVENT ENGINEER IMMEDIATELY OF ANY DISCREPANCIES.

 

 

 

 

 

 

 

 

 

 

 

SCALE: SHOWN
DATE: 17/10/2016
DRAWN: TS
SHEET: S10

 

 

 
Log in to download the original file

ADAMS+SPARKES Operational Works Application (Eenie Creek Rd) 160206.pdf · 11.9 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.