BLOCK WALL TO FUTURE
SPECIFICATIONS
|
eT
FOOTINGS & SLAB TO
FUTURE SPECIFICATIONS —~ ¥
BY ENGINEER
1
SCREW PIERS DIRECTLY BESIDE
SEWER TO BE FOUND BELOW +9——=|
SEWER INVERT. TYPICAL
1450 MIN.
PERP. TO SEWER
FOUND ALL SCREW PIERS
300mm MIN BELOW THE ZONE
OF INFLUENCE. TYPICAL
“FP,
Za
2720 MIN.
NOTE: ACTUAL DEPTH OF
SCREW PIERS TO BE
DETERMINED BY
CONTRACTOR ONSITE.
CONTRACTOR TO ENSURE
A SAFE DISTANCE
BETWEEN SCREW PIERS
AND SEWER AS TO NOT
DAMAGE EXISTING SEWER
DURING INSTALLATION.
$
b
EXISTING 0150 uPVC SEWER LINE.
APPROX. INVERT LEVEL 16.33m
|
SECTION
SCALE 1:20
BLOCK WALL TO FUTURE BLOCK WALL TO FUTURE
SPECIFICATIONS SPECIFICATIONS
de
TT
FUTURE SPEGIF'CATIONS >| " FOOTINGS & SLAB TO
BY ENGINEER |+—FUTURE SPECIFICATIONS
BY ENGINEER
|
SCREW PIERS DIRECTLY BESIDE
SEWER TO BE FOUND BELOW =——+
SEWER INVERT. TYPICAL
1450 MIN.
PERP. TO SEWER
— MIN.
FOUND ALL SCREW PIERS
300mm MIN BELOW THE
ZONE OF INFLUENCE.
TYPICAL
NOTE: ACTUAL DEPTH OF
SCREW PIERS TO BE
DETERMINED BY
CONTRACTOR ONSITE.
CONTRACTOR TO ENSURE
7 ASAFE DISTANCE
BETWEEN SCREW PIERS
AND SEWER AS TO NOT
DAMAGE EXISTING SEWER
DURING INSTALLATION
fet,
EXISTING @150 uPVC SEWER LINE.
APPROX. INVERT LEVEL 15.49m
|
FOUND ALL SCREW PIERS
300mm MIN BELOW THE ZONE
OF INFLUENCE. TYPICAL
NOTE: ACTUAL DEPTH OF SCREW
PIERS TO BE DETERMINED BY
CONTRACTOR ONSITE. CONTRACTOR
TO ENSURE A SAFE DISTANCE
BETWEEN SCREW PIERS AND SEWER
AS TO NOT DAMAGE EXISTING SEWER
DURING INSTALLATION.
1940 PERP. TO SEWER
SCREW PIERS DIRECTLY BESIDE
[> SEWER TO BE FOUND BELOW
SEWER INVERT. TYPICAL
| ra
EXISTING 0150 uPVC SEWER LINE.
APPROX. INVERT LEVEL 14.96m
cle m SCALE 1:20 SECTION
y=
BLOCK WALL TOFUTURE___ [7 Z UW
SPECIFICATIONS tet) B | SCALE 1:20
z |-—EXISTING BLOCK WALL
>
‘ - REFER SHEETS S6 & S7 <
= FOR SLAB SPECIFICATION, Z
ra SECTIONS AND DETAILS 8
L
NOTE: SCREW PIERS
secret roms
BOUNDARY TOBE FOUND RY ENGINEER
BELOWBASEOFEXISTNG & ae
FOOTINGS OF EXISTING 3 UW
STRUCTURES. ACTUAL S a |___EXISTING RETAINING
DEPTH OF SCREW PIERS WALL TO REMAIN
TO BE DETERMINED BY
CONTRACTOR ONSITE. |
EXISTING FOOTINGS EXISTING CARPARK SLAB
fo &SLAB
SCALE 1:20 SECTIONS NEAR SEWER SCALE 1:20
SCALE 1:50
0) haw SP T: (07) 5443 6585 & [UEC PIL PROPOSED INDUSTRIAL BUILDING FIGURED DIMENSIONS TO TAKE PRECEDENCE APPROVED 216130
ud (07) 5479 1754 _& 8 EENIE CREEK ROAD OVER SCALED MEASUREMENTS. VERIFY ALLON | F>==———Feear SHOWN
su se SITE DIMENSIONS & LEVELS WITH THE SUPPORTING
® & jtcengineers.com.au xB NOOSAVILLE, QLD DOCUMENTATION PRIOR TO THE COMMENCEMENT Re NED DATE: 17/10/2016
™ S oe inf @t naineer: m. 2 z a A 47/10/2016 | OP WORKS APPROVAL OF ANY CONSTRUCTION. CONTRACTOR TO NOTIFY DRAWN: TS
© oy MOyicengineers.com.au s = Sy. JOR DESCRIPTION issue | ATE EVENT ENGINEER IMMEDIATELY OF ANY DISCREPANCIES, SHEET. 3