ADAMS+SPARKES Operational Works Application (Eenie Creek Rd) 160206
Attached to the e-mail Operational Works Application - OPW16/0235.
Very large file (11.9 MB): the original may take a few minutes to open or download. The page text below is quick to read.
CONSTRUCTION NOTES: GENERAL NOTES G.1. THESE DRAWINGS ARE TO BE READ IN CONJUNCTION WITH THE ARCHITECTS AND OTHER CONSULTANTS DRAWINGS AND SPECIFICATIONS. ANY DISCREPANCY TO BE REFERRED TO THE ENGINEER IN WRITING. G.2, ALL DIMENSIONS ARE TO BE CHECKED ON SITE AND VERIFIED BY THE CONTRACTOR BEFORE WORK COMMENCES. G.3. DIMENSIONS SHALL NOT BE OBTAINED BY SCALING THE STRUCTURAL DRAWINGS. COMPACTED FILLING CF.1. ALL COMPACTED FILL SHALL BE MATERIAL OF MINIMUM CBR 15%. THE MAXIMUM PERCENTAGE (BY MASS) OF MATERIAL PASSING THE 0.425mm SIEVE SHALL BE 22%, THE MAXIMUM LIQUID LIMIT OF THE FINES COMPONENT OF THE MATERIAL SHALL BE 28% AND THE MAXIMUM PLASTICITY INDEX SHALL BE 6%. THE GRADING CURVE OF THE MATERIAL SHALL BE SMOOTH WITH 100% OF MATERIAL PASSING THE 19mm SIEVE. ALL COMPACTED FILL SHALL BE COMPACTED AT OPTIMUM MOISTURE CONTENT TO 100% COMPACTION TO. AS1289 - E1.1. ALL FILL SHALL BE PLACED IN COMPACTED LAYERS OF NO MORE THAN 150mm THICK. THE CONTRACTOR IS TO CARRY OUT ONE COMPACTION TEST PER EVERY 500sq.m, FOR EVERY SECOND LAYER OF FILL. CF.2. REMOVE ALL EXISTING FILL FROM THE SITE. COMPACT THE TOP 300mm OF THE NATURAL GROUND UNDER THE BUILDING TO A DISTANCE OF 1.5m BEYOND THE EXTERNAL PERIMETER OF THE BUILDING TO 100% MODIFIED COMPACTION. THE COMPACTED FILL (AS PER CF.1.) SHALL BE COMPACTED IN LAYERS TO 95% STANDARD COMPACTION TO WITHIN 300mm OF THE FINISHED GROUND LEVEL. THE REMAINING 300mm OF FILL SHALL BE COMPACTED IN TWO LAYERS TO 95% STANDARD COMPACTION. COMPACT ALL FILL TO A DISTANCE OF 1.5m BEYOND THE EXTERNAL PERIMETER OF THE BUILDING. EARTHWORKS NOTES: 1/ ALL EARTHWORKS SHALL BE IN ACCORDANCE WITH AS3798-1996. 2/ STRIP ALL VEGETATION & TOPSOIL & REMOVE FROM SITE. 3/ CONTROL TESTING OF EARTHWORKS SHALL BE UNDERTAKEN IN ACCORDANCE WITH AS3798. GEOTECHNICAL CERTIFICATION TO BE TO LEVEL 2. 4/ ALL FILL MATERIAL SHALL BE PLACED AND COMPACTED TO THE FOLLOWING STANDARDS (UNO.) (1) COHESIVE MATERIAL FILL SHALL ACHIEVE A MINIMUM DRY DENSITY RATIO (M.D.D.R.) OF 98% Std SUBGRADE SHALL ACHIEVE 98% Std M.D.D.R. (Il) NON COHESIVE MATERIAL FILL SHALL ACHIEVE A MINIMUM DENSITY INDEX RATIO OF 80%. 5/ FIELD DENSITY TESTS SHALL BE UNDERTAKEN AT A FREQUENCY OF ONE TEST PER 200m3 DISTRIBUTED REASONABLY EVENLY THROUGHOUT FULL DEPTH AND AREA OR THREE TESTS PER VISIT, WHICHEVER REQUIRES THE MOST TESTS. FIELD DENSITY TESTS OF EXCAVATED SOFT GROUND SHALL BE UNDERTAKEN AT A FREQUENCY OF ONE TEST PER 100m3 DISTRIBUTED REASONABLY EVENLY THOUGHOUT FULL DEPTH AND AREA. 6/ FIELD DENSITY TESTING OF TRENCH BACKFILL SHALL BE UNDERTAKEN AT A FREQUENCY OF 1 TEST PER 2 LAYERS PER 20 LINEAR METRES. STORMWATER DRAINAGE NOTES: 1/ REFER TO DRAW No. 213023 SHEETS OW1-OW5 CALCULATION TABLES. 2/ ALL PIPES ARE uPVC OR FRC CLASS AS NOTED. 3/ ALL STORMWATER MANHOLES TO BE STD 1050 DIA U.N.O. IPWEAQ DRAW No. SEQ D-010 4/ ALL STORMWATER PITS TO BE IPWEAQ TYPE 2 U.N.O. CONCRETE CARPARK CONSTRUCTION NOTES: 1/ ALL CONCRETE TO CARPARK TO BE F'c = 32MPa 2/ SLUMP 50mm - 80mm 3/ MAX WATER/CEMENT RATIO = 0.6 4/ FINISH SURFACE OF CONCRETE WITH A LIGHT BROOM 5/ CONCRETE 150mm THICK REINFORCE WITH No.1-LAYER SL82 FABRIC 50 MIN TOP COVER. N16 TRIMMER BAR a CURING NOTE:**IMPORTANT NOTE* fs ec 1/ THE CONTRACTOR IS TO APPLY ALIPHATIC ALCOHOL TO THE SURFACE OF THE SLAB TO PERIMETER & 3 IMMEADIATELY FOLLOWING SCREEDING & BULL FLOATING. THE ALIPHATIC ALCOHOL IS TO — = BE RE-APPLIED IMMEADIATELY AFTER EACH SURFACE OPERATION. THE ALIPHATIC ALCOHOL IS TO BE APPLIED STRICTLEY IN ACCORDANCE WITH THE MANUFACTURERS SPECIFICATIONS. 2/ THE CONCRETE IS TO BE COVERED BY AN IMPERVIOUS SHEET AND WET CURED FOR A MINIMUM OF SEVEN DAYS. THE CURING OPERATION IS TO COMMENCE ON THE SAME DAY THE CONCRETE 3/ SAW CUT JOINTS 45MM DEEP ARE TO BE INSTALLED WITH AND EARLY AGE CONCRETE SAW AS SOON AS POSSIBLE AFTER THE SLAB HAS BEEN CAST AND WITHIN 1hr FOLLOWING THE = 150mm THICK SLAB SL82 MESH 50 TOP COVER F'c=32MPa MIN 50mm SAND BED SECTION SCALE 1:20 (A3) CONCRETE DETAILS COMPACTED SUBGRADE SCALE 1:20 10mm JOINTEX OR EQUIVALENT. _ g| / - © " PIV: N16 TRIMMER ABUTTING PAVEMENT OR OTHER STRUCTURE MIN 50mm SAND BED ISOLATION JOINT (IJ) SCALE 1:20 NOTE: ALL JOINTS TO BE SEALED PRIOR TO BUILDING HANDOVER "DANLEY" PLATE DOWEL CRADLES 6mm @ 600 CRS FOR 150mm SLAB GALVANISED DOWELLS PROVIDE 45mm DEEP SAW CUT TO SLAB WITH EARLY ENTRY SAW WITHIN thr AFTER FINAL FLOAT FINISH ¢ Poe | = MIN 50mm INDUCED CRACK SAND BED SAWCUT JOINT (SJ) SCALE 1:20 6mm x 110mm SQUARE HOT DIPPED GALVANISED “DANLEY" DIAMOND DOWELS @600 CRS INSTALLED IN ACCORDANCE WITH THE APPROVED SEALANT MANUFACTURERS SPECIFICATIONS = MIN 50mm SAND BED CONSTRUCTION JOINT (Cu) SCALE 1:20 oe T: (07) 5443 6585 i F: (07) 5479 1754 @ & jtcengineers.com.au Q&@ [email protected] MAROOCHYDORE BC QLD 4558 PO BOX 5960 PROPOSED INDUSTRIAL BUILDING APPROVED 216130 FIGURED DIMENSIONS TO TAKE PRECEDENCE 8 EENIE CREEK ROAD OVER SCALED MEASUREMENTS, VERIFY ALL ON SITE DIMENSIONS & LEVELS WITH THE SUPPORTING | JOHN TITMus SCALE: SHOWN NOOSAVILLE, QLD RP.E.Q. 4092 DATE: DOCUMENTATION PRIOR TO THE COMMENCEMENT 17/10/2016 SIGNED A {17/40/2016 | OP WORKS APPROVAL OF ANY CONSTRUCTION. CONTRACTOR TO NOTIFY DRAWN: TS JOB DESCRIPTION ISSUE} DATE EVENT ENGINEER IMMEDIATELY OF ANY DISCREPANCIES. SHEET: s7
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.