Council archive · source document
20180120 - 180227 24 SBRd GENERAL SCOPE OF WORK · MCU15/0076.01
Attached to the e-mail Generally In Accordance- MCU15/0076.01.
Andrew Bock Architecture
Facade cappings New black powdercoated steel cap
flashings as required.
Awning timber New timber batten horizontal soffit Clear finished select timber (Western Red Cedar?) 90x40 120mm spacing, treated with
battens Cutek or Whittle Wax preservative or similar suspended from black alum powdercoated angle
rail support system off extg structural trusses.
Awning structure Paint Extg Steel structural framing to be painted black
Ceilings outside Plywood, clear finish
between beams
Awning Glass Extg glass has some delamination Evidence of delamination at the edges where sheet butt joint with a silicone joint. This is
staining and may be difficult to clean primarily cosmetic according to the Glazier and the edged captured inside the framing top hat
effectively sections should be fine. We can easily cover the silicone joint with a strip of black PC alum,
however he is concerned that the years of scale build-up might be able to be removed.
Suggested speaking with a specialist cleaner to get more advice. A self-cleaning application
could be applied but it will need the glass to be very clean prior to application.
Alternative option is to replace glass with new selected tint self-cleaning glass to a colour of
our choice. He is able to give a budget quote.
Battens above Black Powdercoated alum box sections Fixing cleats to the purlins will need to be either screw fixed through top hat section (with
glass awning fixed to two cross purlins- one to run upper piece removed) to the tops of the extg painted trusses or if new roof is fitted cleats can
along top edge of glazed awning and the be welded in place when entire glazed framing system is removed.
other to run along half way down the roof
28 Jan 2016 Andrew Bock Architecture
ABN 28 380 947 703
[email protected]
PO Box 2152 Noosa Heads Queensland 4567 Australia
M 0412 116686
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
20180120 - 180227 24 SBRd GENERAL SCOPE OF WORK.PDFRelated documentApplication case desk ↗
About this file
- File size
- 99 KB (small file)
- File type
No other editions are linked here.