Performance outcomes Acceptable Outcomes
PO41 AO41.1
Mixeduse buildings are designed and operated to ensure: Business uses which operate outside the hours of 6:00am to
(a) business uses manage potential impact on residents, 9:00pm are designed and operated to minimise impacts on the
including impacts associated with: amenity of residents of mixeduse buildings.
(i) visual and acoustic privacy; AO41.2
(ii) safety and security; and Residential uses are designed to incorporate suitable noise
(iii) lighting. attenuation and privacy measures to reduce amenity impacts from
business uses.
(b) residential uses do not limit the business opportunities of
the site; and AO41.3
(c) residential uses have reasonable privacy, security and The residential component of the development provides for:
private outdoor living space. (a) separate identifiable residential entries from entrances for
other building uses;
(b) clearly defined and safe pedestrian access to dwelling
units and accommodation units that are appropriately lit,
visible to others and directly accessible to units from areas
likely to be used at night;
(c) security measures such that building users do not have
access to areas that are intended for the exclusive use or
residents of, and visitors to, residential accommodation;
(d) windows, balconies, terraces of each dwelling are
screened up to a minimum height of 1.7 metres from the
finished floor level where overlooking a habitable room or
private open space of another dwelling within 9 metres; and
(e) screening may incorporate solid translucent screens,
shutters, perforated panels or trellises which have a
maximum of 50% openings.
Editor's note—refer to figure AP31B and figure AP31C for
design outcomes for overlooking.
AO41.4
Dwellings provide:
(a) clearly identify private residential space by using features
such as low walls, changes in surface texture or other
landscape treatments.; and
(b) private open space or an open balcony directly accessible
from a habitable room:
(a) with a minimum area of 9m²,
(b) with a minimum dimension of 2.5 metres; and
(c) clear of any utilities such as gas, water tanks and air
conditioning units.
Amenity and Safety Table 6.4.2.3 Criteria for assessment (part)
Performance outcomes Acceptable Outcomes
Amenity and safety