Original source · versioned page text
Acoustic Report - Multiple Dwelling Development 99-105 Eumundi Rd Noosaville (ver B)
Proposed Multiple Dwellings
99-105 Eumundi Noosa Rd, Noosaville
Acoustic Report
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
6.0 RECOMMENDED ACOUSTIC TREATMENTS
6.1 Noise impacts from Surrounding Noise Sources on the Proposed Development
Existing noise levels were measured at the site. During the measurements the commercial businesses were
in operation. These measured noise levels were then used to determine a series of acoustic treatments in
order to achieve the internal Acoustic Quality Objectives from the Environmental Protection (Noise) Policy
2008.
In order to achieve the required internal Acoustic Quality Objectives from the Environmental Protection
(Noise) Policy 2008 if proposed that a series of acoustic treatment be applied to the proposed development.
Details of the required acoustic rating of these elements are included in that table below and over the page.
Further details of the calculations used to determine these ratings are contained in the appendix of this
report.
Building Recommended
Apartment Room Elements Minimum Acoustic
Treatment Rw
Building 01
101
Living Room
Sliding Doors Rw 26
Bedrooms 1 & 2
Windows Rw 24
102-104
Living Room
Sliding Doors Rw 26
Bedrooms 1 & 2
Windows Rw 24
105
Living Room
Sliding Doors Rw 25
Bedrooms 1, 2 & 3
Windows Rw 24
Table 5 : Recommended Acoustic Ratings Rw Of Building Elements
In Building 01
Decibell Report No. 2108055 Page 11