GENERAL NOTES                                                             DISCREPANCIES
                                                                                                                                             TIE - DOWN information and Details Refer
MEASURE ON SITE TO CHECK ALL DIMENSIONS                                   Any discrepancies in dimensions of these drawings                  to Structural Engineers
PRIOR TO SETTING OUT FOR NEW WORK                                         should be
                                                                          pointed out to the designer and any details not shown               RUBBISH & DEBRIS
The builder shalt verify location of all services, all dimensions         should                                                             All materials deemed to be unusable shall
and levels prior to commencement of any work.                             be requested by the builder in writing. no responsibility is       be placed in a rubbish compound or a industrial
                                                                          implied for any inaccuracies or omissions from these               bin and removed from the site at the earliest opportunity.
This building shall be constructed in accordance with the                 drawings
Australian Domestic Construction Manual (ADCM), Building                                                                                     Scaffolding
Act and Building Codes of Austratia (BCA) relevant codes and                                                                                 All scaffolding shall be in accordance to the
regulations, and in accordance to the TRADAC Timber Framing               WATERPROOFING: Waterproofing to wet areas are to be                Queensland Heath and Safety obligations and the
Manual., and in accordance to all Manufacturer's specifications           carried out in accordance with Standard AS 3740 &                  Workplace Health and Safety Act 1995
and installation details.                                                 relevant
                                                                          BCA codes and requirements.                                        Artificial Ventilation or Mechanical Ventilation
Set-out dimensions shown on the Site plan shall be confirmed                                                                                 is to be in Accordance to AS 1668 Part2-1980 3.8.4 & 3.8.5
by the Builder before commencement of construction &                      TERMITE PROTECTION: The Builder shall provide for
ordering of materials.                                                    Termite protection to be carried out by an approved                RENDERING AND PAINTING
                                                                          licensed Pest Control specialist in accordance with AS             Refer to Schedule of finished and consult with
Positions of Down Pipes (DP) & storm water drains and levels              2057-1986 or the latest AS 3660-1                                  the Building Supervisor or Primary Builder for
are to be confirmed before final grading. The builder is to ensure                                                                           all information pertaining to finishes and colours.
that surface water (rain water) is to be diverted from the envelope       Construction shall be in accordance to AS 1170.1, AS
of the building on all sides at all times.                                1170.2 AS 1664, AS 2870, AS 3600, AS 1480, AS2870-
                                                                          1996 and the standard Building Laws and Building Code of
Sanitary drainage shall be in accordance to the local authority          Australia and relevant Codes and the Australian Domestic
requirements & with the prepared hydraulics drawings.                     Construction Manual for the Terrain Category W41N
Check position of overflow relief gully & top of slab level if           WATERPROOFING: Waterproofing to wet areas is to be
required.                                                                 carried out in accordance with Standard AS 3740 &
                                                                          relevant BCA codes and requirements.
A final as build drawing shall be provided to the owner on
completion                                                                                                                                   NOTES:
showing position of all services.                                         SITEWORKS                                                          1      Design in accordance with BSA
                                                                          Refer to Engineer's drawings and details for all reinforced        2      All construction to be in accordance with
                                                                          concrete work, levels, Retaining Walls Details, Driveways,         the following Australian standards and
NOTES:                                                                    Planter Boxes and any other work involving Hydraulics or           Codes as referenced in the Building Code of Australia
                                                                         Waterproofing
These drawings shall be read in conjunction with all                                                                                         AS 1736-1975        code of practice for pliable sarking
other drawings, consultants’ drawings specifications,                                                                                        AS 1562-1980        design and installation of metal roofing
schedule of finishes and with such other written instructions.                                                                               AS 2050-1989        fixing of roofing tiles
All and any discrepancies shall be referred to the                                                                                           AS 2870-1988         residential slab and footings
designer for decision before proceeding with any work.                                                                                       AS 2904-1988         masonry in buildings
                                                                                                                                             AS 1684.2-1999       code of practice for construction
Any changes omissions or variations which the                                                                                                in timber framing
contractor may wish to make shall be discussed
with the designer before any work commences

    (Nyichael Petrascu Designs                                                  Proposed Residences                                                 GENERAL NOTES
                   BSA Nr 703843                             Lot 2 Orealla Cres Sunrise
       PO Box 651 Noosa Heads Qld 4567                       Beach Qld                                                        Lot 2 Orealla Cres                                           013
      Tel: 07 54 472 996 Fax: 07 54 492 450
       email: [email protected]                                                                                                           rGreckedty        ——htker Seale

Used in these records

About this file

File size
1.7 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

00156934.001.pdf · 1.7 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.