160884Dw · OPW16/0150
Attached to the e-mail OPW16/0150 - Operational Works Application 2of2.
Original PDF page 1, section 1. The text section number identifies this passage in the reader.
LINDSAY CONSULTING PTY
LTD
STREET
EXISTING FOOTPATH
EXISTING SEWER LINE
HENDERSON
Saw cuts every 4.5m
crs and Key Joints
every 3 saw cut.
SMH
SL35.80
IL 34.36
DRIVEWAY
LONGSECTION 1
5600mm at Kerb to match existing
New Concrete
4600mm to match existing
driveway 125mm thick.
SL72 fabric centrally
New Concrete
driveway 125mm thick.
SL72 fabric centrally
Builder to confirm if
any re-instate of kerb
and channel is
required.
600mm landscape
Existing Neighbouring
Timber retaining wall strip
Existing timber retaining wall to be
replaced with new Blockwork
EXISTING FOOTPATH
retaining wall to builders Existing Water meter
specifications and continue out to
the footpath.
All AHD levels provided are
existing levels provided by
owner.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 6 sections
Section 2
125mm THICK CONCRETE
DRIVEWAY, N25
Existing Sewer Main Dia 150 UPVC
LINDSAY CONSULTING PTY
LTD
UIL 34.36. Depth of pipe 1.44m.
630mm of cover between underside
of concrete and top of pipe.
ALL SERVICES HAVE BEEN LOCATED
BY ALL UNDER GROUND PIPE & CABLE
LOCATORS AND CONFIRMED BY
TOK 34.83 RELEVANT SERVICES
SM
Section 3
ALLOWABLE NUMBER AND WIDTH OF RESIDENTIAL DRIVEWAYS LEGEND ALLOWABLE max WIDTH max WIDTH Woe DESCRIPTION No. OF AT KERB Wo AT. PROPERTY cal an vee hee , (DRIVEWAY PROHIBITED LOCATIONS) CROSSINGS INVERT BOUNDARY riveways subject to relevant counci (W1) (w3) approval.) NKL nominal kerb line (face of kerb) 1 Singl | 4.0 3.0 3.0 a ingle _gorage m m m TP oo Tangent point on NKL > g 2 Double garage or more | 4.0m 3.0m 5.0m Prohibited locations shown in a : heavy line, based on AS 2890.1 4 3 Double garage or more 2 4.0m 3.0m 5.0m 1. min 40.0m frontage; : . oo : S 2. min 12.0m between two crossings. X The points marked X are either a Double carage or at the median on a divided road, 4 2 g t 1 5.0m 4.0m 6.0m Subject to carport/garage approval. or at the intersection of the main socrdary property road centreline and the y prolongation of the side road NKL S< 5 Duplex with frontage 1 5.0m 4.0m 6.0m line on an undivided road. 4 20.0m or less S a 6 Duplex with frontage 2 5.0m 4.0m 5.0m min 7.0m between crossings. greater than 20.0m General 4000 verge Existing/future concrete path Stormwater kerb inlet Typical carpark bay Dowelled expansion joint ae) oN Kerb and channel Kerb refer to RS-065 8 1.0m clear of taper local area traffic Single garage alignment © management 2 . \ /\ [ Property boundary 2 devices ° Ss ® 1.0m clearance | SIE z £ from pit lintel 8 L Ss o 4 aay S s S = S - NOTE: 1 S| 4 \ 5 1. Services & road furniture will &/&§& ES§ 2 5 not be moved for driveways. TP xe St TP TP ofo 1S Sto TP A _ > ws So om 2. This drawing to be read in = f ie = ' t — = S| S$ > 8 conjunction with RS—050. _ — NKL 2 a 1 = |= 1 e Refer sections A+B on 6.0m xX 6.0m 6.0m 6.0m s drawing number RS-050 Median Centreline of main road Y NKL NKL 500 max vertical 4 transition length | | 6.0m 6 0m Sawcut to allow clean removal | 1500 | of back of kerb and channel Existing path to be saw cut and removed prior to crossing construction COLLECTOR ACCESS Existing/future concrete path refer note 23 on RS-050 SETOUT REQUIREMENTS DRIVEWAY PROHIBITED LOCATIONS These drawings have been developed in consultation between the participating Councils. BEFORE USE, the user shall confirm that the drawing has been adopted by the appropriate Council. INSTITUTE OF PUBLIC WORKS ENGINEERING AUSTRALASIA aes H RESIDENTIAL DRIVEWAYS - | Bl 06/14 | Review STANDARD DRAWINGS RS—049 8] 10/12 | ORIGINAL ISSUE PLAN 1 OF 2 A DATE REVISIONS,
Section 4
x >
HEIGHT ABOVE INVERT] o <0 2 2 3
OF CHANNEL (mm) | = a A 3
Control joint DISTANCE FROM INVERT] o 19 o 0 >
300 ie OF CHANNEL (m)_ 1 7 oo 5 1500, 1500 _, 1500
. min - eo] Roll over Garage/
Kerb invert a
. Carport slab
_ 1500min Slope may vary | ee
r Road surface o 1500 refer note 13. 500 refer note 12 int
= Transition Path zone 6
sg 1 in 40 jo | 1500
. . <1 in Oe ——{—] T in
Reinforced SL72 fabric min = 20 Roll under Garage/
Sand blinding layer 50 max SJ / Carport slab
~ Galvanised/stainless Saw cut all kerbs to Control joint Control joint
steel dowels 400 long allow clean removal of (If required)
R16 @ 450 centres back of kerb and
channel
BREAKOUT TYPE TYPICAL PROFILE DRIVEWAY ACCESS
SECTION A SECTION B
Refer drawing Refer drawing
RS—049 RS-049
NOTE:
1. All appropriate permits must be obtained from relevant council, specifying crossing type, 13. Path zone width may vary to match existing concrete pathways and verge profiles.
construction materials, location, levels, surface finishes and dimensions, prior to any excavation. Path earthworks adjoining concrete must be well compacted.
2. Alternative materials for construction, other than reinforced concrete, refer to relevant council 14. Earthworks cut and fill batters from edge of driveway or path to natural surface to be
for approval. maximum grade at 1 in 10 and fully turfed prior to council inspection.
3. Crossing to be constructed square to the street alignment, wholly contained within the site 15. Existing path to be longitudinally transitioned to new driveway at a maximum grade of 1 in 10.
frontage from invert of channel to property boundary. 16. Plain concrete surfaces to be heavy broom finished.
4. One access to be constructed per allotment unless otherwise approved by relevant Council. 17. Decorative surfaces are subject to relevant council approval, where approved, to have a Smm
5. To reduce impact on available street parking, consideration is to be given to visitor’s and max depth variation in the finished surface profile. All finished surfaces of driveways are to
neighbouring property’s parking needs when selecting a crossing location. comply with the requirements of AS/NZS 3661.1 slip resistance of pedestrian surfaces.
6. Crossing to be located clear of existing gully pits. where this cannot be achieved, the gully pit Exposed aggregate finish subject to relevant council approval due to environmental reasons.
and pipework may be relocated at the property owner’s expense, subject to approval of the 18. Expansion joints to be 10mm thick full depth closed cell cross linked polyethylene foam (85 —
relevant council. 150 kg/m), or 8.5mm thick bitumen impregnated compressed granulated corkboard, installation
7. Crossing to be located clear of all service authority’s fittings, manholes and pits. Subject to to manufacturers’ instructions. Seal surface of joint with a suitable polyurethane sealant.
relevant Council approval, where this cannot be achieved, existing service pits are to be 19. Concrete surface tolerance to be, +2™™over 3 metre sections.
contained within the area of new driveway, pit surface to match approved driveway finished 20. Concrete to be minimum grade N32 in accordance with AS 1379 and AS 3600.
levels. 21. Concrete construction to comply with the requirements of AS 3600, concrete code.
8. Kerb adaptors and associated roofwater drainage to be located clear of vehicular crossings. 22. Reinforcement fabric to AS 1304, 50 top and edge cover, lap fabric 250.
9. Council will not relocate traffic islands or provide breaks in traffic islands to allow driveway 23. Control joints are to be sealed with a low modulus self priming sealant to the manufacturers
access. specification. refer RS—065.
10. For water sensitive urban design verges, the vehicular crossing is subject to relevant council 24. Formwork and reinforcement shall be in place and inspected and approved by the relevant
design and approval. council prior to placement of concrete.
11. **Driveways must achieve a high point of 250mm above invert of kerb to ensure stormwater is 25. Maintenance of the crossings are the responsibility of the property owner.
contained within the road reserve as per requirement of Q.U.D.M. (Queensland Urban Drainage 26. Drawing to be read in conjunction with RS—049.
manual). This constraint may be varied upon the approval of the relevant Council. 27. Cross fall of existing pavement adjacent to the driveway to be checked. If cross fall exceeds
12. Under special circumstances Council may approve a rising grade of 1:6 max or falling grade 3%, relevant Council will decide if driveway needs to be re-designed to ensure satisfactory
of 1:20 min Longitudinal grades along property boundary must allow for free drainage and clearance for vehicles. .
28. All dimensions are in millimetres unless shown otherwise.
pedestrian safety.
These drawings have been developed in consultation between the participating Councils.
BEFORE USE, the user shall confirm that the drawing has been adopted by the appropriate Council.
E| 06/14 | Review
D| 10/12 | Review
C| 06/10 | Review
BI| 06/09 | Review
A| 03/08 | ORIGINAL ISSUE.
Rv _BATE REVISIONS,
INSTITUTE OF PUBLIC WORKS ENGINEERING AUSTRALASIA
STANDARD DRAWINGS
DRIVEWAYS Hy
RESIDENTIAL DRIVEWAYS RS-050_ [¢
PLAN 2 OF 2 nN
Section 5
1
6BUP
954
6 SGM2
534
#848
3 4
#
4
!
0
DETAILED INFRASTRUCTURE MAP
S
G M
253
386
8
8
0BUP
104
215
28
S
M 2
665
387 S
M 2
665
395
0
2
Lot Number: 0
M
S
S27
991
29! S
S28
044
37
1
B U
P10
421
5
P
W
Plan Number: BUP3585
0
B U
P95
46 1 BUP106270
10BU P1062 70 0
S P
116
605
S
Printed On:
1
S P
230
070 4
# 3
B UP106270
G
S
S27
991
32
M
11/07/2016 6BUP106270
4
25
#
Sequence No: 1057186004 8BU P106
27 0
33
4
# 11BUP106270
86
S
M 2
665
388 4
7
1
2B
#U
4 P1062 70 #
4
#
Emergency Situations
4
# 12/2
1 4
#
2
! 11/2110/21
0
Call Unitywater:
4S P1 1
660 5
8
4
# 9BU P1 06270
8
1S P
4
#1 1
660 5
S
2
1300 086 489
000
00BU P 106270
G
0
SS
2799
130 3
S P1 16605
2
M
4
M
4
# 4BU P1#06270 5/201/20
2
0
B U
P10
2822
5
7BU P 106
270
P
# 4/202/20
4
W
3
0
B U
P10
6270
3
This information on this plan is valid
5 BUP1062
70 00 00 0SP116605
8
4
# 4
#
S
6
2BU P 106
270
# 2S
4 P11 660
5
5
2 1
G
for 30 days from "Printed On" date. 5SP 116605
M
7BUP102822 4
#
2
4
B UP10
2822
Legend
5
S
S27
991
33 4
#
3
9BUP102822
38
5BUP1
0 282
2 4
# 4
#
7
0
0000BUP102822
0
! !
Extent of Unitywater Area Sewer Service 9/47 S
S27
991
31 d
7/478/47 S
M 2
665
389 4
# S
M 2
665
391
Water Sewer sGravity Main 8
B
2
B
U
U
P
P
1
1
0
0
2
2
8
8
2
2
2
2
4
# !
000
00S P
1 9588
0
1
9
Water Pump Station
6
B UP102822 1
S P
1958801/18
Ú
3 Sewer Pressure Main 3BU P1028
22 0
G T
P 6
89
2/1
8
1BU P1028
22 2
S P195880
M Water Service Sewer StoragePipe
9
(
l
6
T
4
#
8
E
3
SS27
991
35
Water Valve
E
d
3
Sewer Pipe (Abandoned) 4
4
7 # 0
S P
195
880
R
4
/19
5
1
/19 3
/19
2
T
4
G T
P 6
893 2GT
P 6
89
M
S
NS
G T
P 6
89
Water Hydrant
G
Recycled Water
G
! 5
1
M
S
O
2
2
/19
S
S
M 2
665
390
5
4
03RP
481
12
Tapping Device Recycled Water Pump Station
3
R
"
) Ú
[ 1
G T
P 6
89
3
E
8
61/16
D
1
6
S
Water Main
G M 2/1
6
Recycled Water Hydrant
N
4
! 253
386 S
M 2
665
920 2
S P
142
276
! 6 1S P14
2276
E
S
S27
991
36
H
0000
0 SP142
276
Trunk Main 4
#
Recycled Water Valve
d S
S27
991
34
! S
G
S
S27
991
37 M
253
369
7
Reticulation Main
1
! 0
G T
P 4
10
Recycled Water Fitting
2
V
g S
M 2
665
866
6
!
8
Water Service
3
0
S P
193
676 S
S28
044
34
4
0
Recycled Water Main
9
M2
6
0000
0 BUP358
5 0
B U
P3585
3
Water Pipe (Abandoned)
5
P
3
W
3BUP
35 85
0
Recycled Water Service
5
71/1
7 1
4
5
3/1
2
4
M
72/17
Sewer
1
7 4 /1 4
23RP
48112
3
5 2 BUP3585 SM266
5867
G
5
4
B U
P358
Recycled Water
2
1BUP3585
S
M
5S P193676 4
#
!
Sewer Pump Station Pipe (Abandoned)
G
Ú
[ 2SP 19367
6
S
4SP 1
936 76 4
# S
G M
2 S
G M
253
372
6
5/531/53 53
369
5
d Sewer Valve 4/532/53
S
M 2
Section 6
665
869
1SP1 93676 4
#
Sewer Connection Point
5
3
! 0
0000 SP1 9
3676 !
3SP1 93676
! Sewer Manhole
1
/12 S
S28
029
71
1
B U
P13
534
Map Tile: 1
±
2
/12
Scale:
3
S
S28
029
72
2
2
B U
P13
534
1:500 S
M 2
665
845
7
13B UP927
7 1
2
(If printed at 100%
3
4 ! 3
/12
3
# 4 BUP9277
5
3
B U
P13
534
on A3 size paper)
2
M
9 BUP9277
G
S
S27
991
38 6B UP9277
S
14BUP9 2
77 0
B U
P92
77
4
#
1
S P
188
1 822 SP1
88182 1
1 2BUP 9
27 7 0
B U
P13
534
1 72
/5 /5
7 12BUP927
7 3
B U
P 4
0 8
4
4
# 0S
P18
818
2 00004
0
#SP18818
2 11/1
11 2/11
3/462
14/1113/11 /4
6
Geospatial Information Systems 1
1B UP92771 B
U P9
277
Ground Floor, 33 King St
8BU P9277
5
7 4
#
Caboolture QLD 4510 5
B UP9
277
Inquiries: 1300 0 Unity (1300 086 489)
S
S27
991
39 4
6
T
3
B UP9
277
E
0
S P
188
183 P
A 4
# 0B UP4084
Email: [email protected]
4
E
# 000
00BUP92
77 S
M 2
665
868 R KC
R
4
# W RE
T
2SP188
183 ! P S
AS
S
S27
991
40 M CE
1
S P
1881
832 /59 7
B U
P92
77 2
0 NT
2
Disclaimer ! 84
D
0
0000SP1 8
8183 24
4
N
# 5S
These Maps are supplied under the following conditions:-
1
0BUP
927
7 S
S28
027
14 SM2
6 6
586 P
M
A
50
6
L
5
9
! S9430
4
Mapping details are supplied from information contained in Unitywater’s
E
62
G
d
records which may have been furnished to Unitywater by other persons.
M
8
! 2
3
0
G T
P 3
10 53
Unitywater gives no warranty or guarantee of any kind, expressed,
3
8
0
W 73
4
2
S S2803
173 6
M
P
7
M
implied, or statutory, to the correctness or accuracy of the map details 2
3
P
02
W
3
8
or the degree of compliance with any standards in this matter. Persons 4 4
5
61 # 25
2
7
M
making decisions with financial or legal implications must not rely upon
2SP 12
5002
2
4
08RP48
112
G
7
1BUP429
7 4
# 00000SP125002
3
the map details shown on this plan for the purpose of determining
S
3
1 2
B U
P42973B U
P4297
5
S
S27
9914 0
B U
P42
97 1SP125002
whether any particular facts or circumstances exist and Unitywater
2
4
# 1/9
M
3/92/9 312 0
G TP578
G
9
(and its officers and agents) expressly disclaim responsibility for any 1/3
0000
0B UP42
97 1
4
# 4 1/3
S
#
loss or damage suffered as a result of placing reliance upon this information.
0
S P
181
140 3
G T
P 5
78
1
S P
181
140
4
#
Section 7
Page 1 of 1
DIPS Asset Report
Date:11/07/2016 Time:2:47 PM
No Water Pressure Mains found...
No Recycled Water Pressure Mains found...
No Sewer Pressure Mains found...
Sewer Gravity Mains....
Asset SubType Material Nominal Pipe Length USIL DSIL
Number Diameter
2533694 Reticulation PVC-U 150 11.6 33.58 33.34
Main
2533695 Reticulation PVC-U 150 52 32.19 31.85
Main
2533697 Reticulation PVC-U 150 20.5 38.51 33.62
Main
2533723 Reticulation PVC-U 150 43.4 37.02 34.36
Main
2533864 Reticulation PVC-U 150 24.7 41.78 41.54
Main
2533866 Reticulation PVC-U 150 20.8 41.5 38.6
Main
2533869 Reticulation PVC-U 150 30.2 34.03 33.66
Main
Sewer Man Holes....
Asset Number SubType SL IL Roof Level
2665867 Manhole 35.8 No Info 35.8
2665920 Manhole 39.8 No Info 39.8
2665390 Manhole 43.8 No Info 43.8
2665866 Manhole 35.44 No Info 35.44
Sewer Services....
Asset Sub Type Connection OB Surface Invert level HBC IO Distance
Number Type Distance level Length
2799134 Service UNK No Info 43.8 43.1 No Info 2
2799136 Service UNK No Info 36.2 34.9 No Info 5.9
2799137 Service UNK No Info 42.2 41.3 No Info 10.2
No Sewer Connection Points found...
This document may not, in whole or part, be copied, photocopied, reproduced or Page 1 of 1
translated without prior consent from the CEO, Unitywater.
Printed copies are uncontrolled.
Used in these records
160884DW.pdfRelated documentApplication case desk ↗
About this file
- File size
- 1.5 MB (small file)
- File type
No other editions are linked here.