SETOUT POINTS SERVICE CAUTION CAUTION DANGER
POINT EASTING NORTHING LEVEL LOCATIONS WATER MAIN TELCO ASSETS OVERHEAD
BEFORE YOU DIG ELECTRIC CABLES
1 1007.037 2991.139 46.201
NEW CONCRETE DRIVEWAY CROSSOVER
GENERALLY IN ACCORDANCE WITH SAW CUT EXISTING AC 2 1007.029 2994.946 46.307
It is the responsibility of the
Foreman to contact the relevant
service authorities to ascertain
elstra
IPWEAQ STD DRGS RS-049 & RS-050 3 1007.019 2998.968 46.424 the exact location of services energex
prior to construction.
4 1007.010 3002.883 46.608
01 02 PAVEMENT REINSTATEMENT.
- - REFER TYPICAL ROAD SECTION. 5 1007.001 3006.797 46.770
ELANDA STREET
JOIN NEATLY GENERAL NOTES
JOIN NEATLY
TO EXISTING TO EXISTING 1. DO NOT SCALE DRAWINGS.
2. ALL DISCREPANCIES SHALL BE REFERRED TO THE SUPERINTENDENT FOR CLARIFICATION BEFORE PROCEEDING.
01 02 03 04 05 3. THE CONTRACTOR SHALL NOTIFY THE SUPERINTENDENT IN WRITING OF ALL VARIATIONS ARISING FROM THE CLARIFICATION OF THE
DISCREPANCY.
4. THE CONTRACTOR SHALL SUBMIT DETAILS OF ANY ADDITIONAL COST ARISING FROM A VARIATION TO THE SUPERINTENDENT FOR
APPROVAL, BEFORE PROCEEDING WITH THE WORKS.
5. ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE DRAWINGS, SPECIFICATIONS, CURRENT RELEVANT AUSTRALIAN
STANDARDS, OTHER STATUTORY REQUIREMENTS AND TO THE SATISFACTION OF THE LOCAL AUTHORITY AND THE ENGINEER.
NO 6. NO WORK IS TO COMMENCE ON SITE UNTIL THE APPROVAL OF THE COUNCIL HAS BEEN RECEIVED IN WRITING AND AN OFFICIAL
EDGE OF PATH
TRANSITION SMOOTHLY
4.000
PAVERS
NEW 1.2m WIDE CONCRETE PATH
PRE-START MEETING WITH A REPRESENTATIVE OF COUNCIL AND THE ENGINEER HAVE BEEN HELD. THE CONTRACTOR IS TO OBTAIN
A COPY OF THE MINUTES OF THE PRE-START MEETING AND SHALL COMPLY WITH THE REQUIREMENTS THEREOF.
FROM EXISTING WIDTH AS PER IPWEAQ STD DRG RS-065
IN ROAD 7. ALL CONSTRUCTION SHALL COMPLY WITH THE RELEVANT WORK PLACE HEALTH AND SAFETY LEGISLATION.
8. WORKING HOURS, COMMUNICATIONS PROTOCOLS, SITE ACCESS, AREA FOR CONTRACTORS FACILITIES/STORAGE AND SITE
RESERVE SECURITY TO BE AGREED WITH THE PRINCIPAL AND SUPERINTENDENT.
9. THE CONTRACTOR SHALL PROVIDE ALL MANAGEMENT PLANS, INCLUDING TRAFFIC MANAGEMENT PLAN, ENVIRONMENTAL
MANAGEMENT PLAN AND WORK PLACE HEALTH AND SAFETY PLAN FOR REVIEW AND APPROVAL OF PRINCIPAL AND
NEW PAVED DRIVEWAY ON SUPERINTENDENT, PRIOR TO CONSTRUCTION.
CONCRETE SUBSTRATE. 10. FOLLOWING COMPLETION OF THE WORKS THE CONTRACTOR SHALL CLEAN UP THE SITE AND DEMOBILISE TO THE SATISFACTION OF
REFER DRIVEWAY PROFILE. THE PRINCIPAL AND SUPERINTENDENT.
SURVEY
1. THIS DESIGN IS BASED ON SURVEY PROVIDED BY MARTOO CONSULTING PTY LTD.
2. ALL LEVELS ARE TO AUSTRALIAN HEIGHT DATUM (AHD).
BUILDING OVERHANG
3. THE CONTRACTOR SHALL CONFIRM EXISTING LEVELS, FEATURES AND UTILITIES PRIOR TO CONSTRUCTION.
M1 K&C AS PER NSC STD DRG 9001 1.2m WIDE
0.615 CONC PATH 0.5 1.0 2.3 NOM 4. ALL ELEMENTS OF PROPOSED WORK TO BE SETOUT AND CHECKED BY THE CONTRACTOR'S LICENSED SURVEYOR AND ANY
GRATED DRAIN AS PER DISCREPANCIES ARE TO BE REPORTED TO THE SUPERINTENDENT.
SETOUT POINT
PAVEMENT TO MATCH EXISTING IPWEAQ
30mm AC WEARING COURSE (MIN) STD DRG
125mm BASE COURSE (MIN) MIN 75mm EXISTING SERVICES
RS-065
125mm SUB-BASE COURSE (MIN) TOPSOIL & TURF 1. THE LOCATION OF ALL IN-GROUND AND OVERHEAD SERVICES HAS BEEN DETERMINED FROM FIELD SURVEY, DIAL BEFORE YOU DIG
ENQUIRIES AND INFORMATION PROVIDED BY THE SERVICE PROVIDERS / AUTHORITIES.
RP BDY
0% 20mm FALL -5%
MATCH EXISTING CROSSFALL vvvvvv v v v v v v v v v1 : 6 2. THE SERVICES ARE SHOWN ON THESE DRAWINGS FOR INFORMATION ONLY AND NO RESPONSIBILITY IS TAKEN FOR THE ACCURACY
vv v vv v
v vvvv OR COMPLETENESS OF THE INFORMATION SUPPLIED.
vv v v 1 : 4
vvvv
NATURAL SURFAC vv v vv v 3. NOT ALL EXISTING SERVICES HAVE NECESSARILY BEEN IDENTIFIED AND SHOWN ON THE DRAWINGS.
E vvvv
vvvv
v vv v 4. THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL EXISTING SERVICES ON THE SITE PRIOR TO COMMENCING WORKS.
JOIN TO EXISTING
AS PER IPWEAQ SUBSOIL DRAIN AS PER IPWEAQ STD DRG R140. 5. EXISTING VALVES, HYDRANTS, PITS, ACCESS CHAMBERS AND OTHER UTILITIES SHALL BE MODIFIED WHERE NECESSARY TO SUIT
STD DRG R170 CONNECT TO EXISTING SUBSOIL IF PRESENT. FINAL FINISHED SURFACE LEVELS.
PROPOSED SECTION 01 TYPICAL ROAD SECTION
DUPLEX 1:50 (A1) 1:100 (A3) - PAVER DEPTH DRIVEWAY PAVING.
REFER ARCHITECT'S DRAWINGS.
SL82 MESH
-
125
CONC DRIVEWAY
125
CONC SUBSTRATE
NOOSA COUNCIL 300
EDGE THICKENING
APPROVED PLAN 10mm FULL DEPTH COMPRESSIBLE
SL82 MESH
R16-450 S.S. GRADE 316 DOWEL BARS,
MATERIAL WITH A 10 x 10 SEALANT 400 LONG, IN DOWEL FORM SLEEVES
REFER GOCKEL ARCHITECTS OPW17/0225.02 24 JUL 2018 WITH 16mm INSERTS ON BAR CHAIRS
FOR BUILDING DETAILS
DRIVEWAY INTERFACE DETAIL
STORMWATER DRAINAGE INFILTRATION NOT TO SCALE
TRENCH (INDICATIVE LOCATION ONLY).
15 NO. ATLANTIS DOUBLE FLO-TANKS
AS PER SWMP (3425 x 1224mm).
'RL' : REPRESENTS FINISHED SURFACE LEVEL
CH 0.000
RL 46.659
CH 0.275
RL 46.629
CH 1.215
RL 46.769
CH 2.415
RL 46.789
BUILDING
B DRIVEWAY PAVING ON NOM RL 47.5
RP BDY
CH 5.415
RL 46.339
REFER DRIVEWAY CONCRETE SUBSTRATE.
INTERFACE DETAIL REFER ARCHITECT'S
DRAWINGS FOR DETAILS.
HEADROOM
STORMWATER DRAINAGE INFILTRATION
2.7m MIN
TRENCH (INDICATIVE LOCATION ONLY).
FP FRONT
CH 10.052
RL 45.180
SAW CUT
FP BACK
K&C INV
12 NO. ATLANTIS DOUBLE FLO-TANKS
K&C LIP
1:4
AS PER SWMP (2740 x 1224mm).
CH 13.052
RL 44.800
REFER TYPICAL
B ROAD SECTION
3.0m CURVED TRANSITION
NATURA
L
SURFAC
E
PROPOSED NEW EASEMENT
125mm THK CONCRETE DRIVEWAY 125mm THK 25MPa CONCRETE SUBSTRATE ON GARAGE
CROSSOVER GENERALLY IN ACCORDANCE COMPACTED CBR15 GRAVEL BASE (100mm MIN)
J:\2018\18505BD2_Duplex_61_Elanda_St_Sunshine_Beach\4.CADD\#ACAD\18505_CIVIL.dwg
WITH IPWEAQ STD DRGS RS-049 & RS-050 WITH KEYED CONTROL JOINTS AT 6m CRS &
REINFORCED WITH SL82 MESH GRATED
3.0m CURVED TRANSITION DRAIN
SECTION 02 DRIVEWAY PROFILE
1:50 (A1) 1:100 (A3) - 0 1 2 3 4 5m 0 0.5 1 1.5 2 2.5m
GENERAL ARRANGEMENT
1:100 (A1) 1:200 (A3) 1:50 (A1) 1:100 (A3)
SCALE 1:100 (A1) 1:200 (A3)
COPYRIGHT © Associated Consultants Client Drawn Verified Project Drawing Title Scale Sheet Size
This drawing is subject to SURVEYOR JF DR
copyright in accordance with the
MARTOO CONSULTING PTY LTD
WADE JENNER Designed Verified
61 ELANDA ST, SUNSHINE BEACH
GENERAL ARRANGEMENT AS SHOWN A1
agreement between Tod
Consulting pty ltd (tc) and tc's
client. This drawing shall only be
(07) 5447 2500 JF DR PROPOSED DUPLEX DEVELOPMENT
AND DETAILS Drawing Number
Approved RPEQ No
used for this specific project. ARCHITECT
DOUG REYNOLDS 9072 RDP LOT 408 RP48112 18505-C001
This drawing shall not be used GOCKEL ARCHITECTS Noosa: 07 5449 9600 LOCAL AUTHORITY NOOSA
B 26.02.18 INFILTRATION TRENCH DETAILS JF David Gockel 0488 112 219 Sunshine Coast: 07 5329 3190 Mackay: 07 4840 2337
Signed MCU APPROVAL HORIZ DATUM LOCAL 0 10 20 30 40 50 60 Sheet Revision
for construction until marked as PO Box 61, Noosaville, QLD 4566
A 15.02.18 ORIGINAL ISSUE JF ROL APPROVAL VERT DATUM AHD (OPM44260)
'issued for construction' in the
revision description. Rev Date Revision Description Drawn
[email protected] www.todconsulting.com
ABN 39 128 805 336
26.02.18 OPW APPROVAL RL DATUM RL 49.843 MEASUREMENT BAR - INCREMENTS IN mm
1 of 1 B
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 7 pages
Page 2
1200mm 17
5 8 11 16
7 rl 44.020 rl 43.260 rl 42.750 9
step
step
step
step
step
step
step
step
step
1
sewer line approx
10
4
FINAL LOCATION OF
existing boundar y
sewer easement
TREES TO BE
ELANDA ST
3 DETERMINED AT THE
15
1 PRESTART MEETING
13
2
POOL step
step
step
8 bench 10
12
6
18
BUILDING ENTRY
19
17
ramp ramp
ffl 44.780 rl 44.020 rl 43.260 rl 42.750
7 9
step
step
step
step
step
step
step
step
step
ex rl 46.00 +
ex rl 45.50 +
ex rl 45.00 +
ex rl 44.50 +
ex rl 44.00 +
ex rl 43.50 +
ex rl 43.00 +
ex rl 42.50 +
ex rl 42.00 +
14
Legend:
mature stock tree (100L) to street entr y spp. internal garden beds with shrub screen 1.8m high friendly neighbour timber paling
1 Tur f to road verge 5 9 12 16 Pandanus to back corner
Cupaniopsis planting to boundar y (min 600mm wide) fencing to boundar y
proposed mature stock (100L) large canopy garden bed to rear of allotment over sewer
6 ex-ground Pandanus to pool area 10 13 tur fed rear yard to natural gradient 17 stepped pathway to rear lawn
2 tree to street frontage within development and stormwater easement
site (min 1 per 20m) spp. Banksia integrofolia colour ful & fragrant creeper / climber mature tree stock (100L) to end of viewline
7 11 side access pathway 14
new 1.2m wide concrete footpath to meet up planting to trellis and privacy screens from entr y pathway spp. Dwar f bottle tree -
3
with existing either side of lot 61 garden beds with coastal species (refer to large mature tree stock (200L) to middle NOOSA COUNCIL
8
planting plans) 15 of garden planted 1m from sewer line spp. APPROVED PLAN
4 blusetone crazy pave to driveway slab
Banksia integrofolia
OPW17/0225.02 24 JUL 2018
N 1/10 station st - bangalow - nsw - 2479 ISSUE DATE DESCRIPTION by PROJECT CLIENT DRAWING NAME PHASE REV SCALE
po box 188 - new farm - qld - 4005
A 26/02/18 CLIENT APPROVAL JB
p: 0411710320 e: [email protected]
B 5/03/18 OPW APPROVAL JB
61 ELANDA STREET Claire + Wade Jenner LANDSCAPE PLAN OPW C 1:100 @ A3 DA2
landscape architecture & design studio C 5/06/18 OPW APPROVAL AMENDMENTS JB SUNSHINE BEACH, Q, 4567 Ground Floor PROJECT No 17333
L A R C C O L L E C T I V E
Page 3
sewer line approx
bbq
1 3 ffl 54.400
existing boundar y
sewer easement
ELANDA ST
ffl 54.400 5
2 ffl 54.400
1300mm
4
Legend:
1 bluestone crazy pave to dining terrace roof top planter to act as balustrade, min
4 900mm deep at tree location, 600mm deep
proposed ex-ground pandanus to provide elsewhere
2 shade, shelter and softening to the roof top patterned gravel treatment to adjoining
terrace 5
rooftop -
large format concrete slabs with min 250mm NOOSA COUNCIL
WIDE 250mm deep gravel and planting
3 strips between. Planted with hardy coastal APPROVED PLAN
groundcover/creepers to withstand harsh OPW17/0225.02 24 JUL 2018
climatic conditions
N 1/10 station st - bangalow - nsw - 2479 ISSUE DATE DESCRIPTION by PROJECT CLIENT DRAWING NAME PHASE REV SCALE
po box 188 - new farm - qld - 4005
A 26/02/18 CLIENT APPROVAL JB
p: 0411710320 e: [email protected]
B 5/03/18 OPW APPROVAL JB
61 ELANDA STREET Claire + Wade Jenner LANDSCAPE PLAN OPW C 1:100 @ A3 DA3
landscape architecture & design studio C 5/06/18 OPW APPROVAL AMENDMENTS JB SUNSHINE BEACH, Q, 4567 roof top PROJECT No 17333
L A R C C O L L E C T I V E
Page 4
lightly exposed and sealed
1 agrregate concrete driveway 1 2 3
AND pathways Boral ‘SILVER
FROST’
Bluestone crazy pave
2 driveway and pathways
Pandanus as entry statement
3 and softening to pool terrace
ground cover plants to hide
4 edges of pathways to soften
entry sequence 4
coastal garden rich in texture
5 and form
6 curved lawn edges 6 7 8
Sculptural pallisade style pool
5
7 fencing
Large format concrete slabs
8 with planter division to soften
9
Oragnically patterned gravel
treatment to exposed roof
9 decks to create visual interest
and amenity
-
NOOSA COUNCIL
APPROVED PLAN
OPW17/0225.02 24 JUL 2018
1/10
po
station
box 188
st
-
- bangalow
new farm
-
-
nsw
qld
-
-
2479
4005
ISSUE DATE DESCRIPTION by PROJECT CLIENT DRAWING NAME PHASE REV SCALE
A 26/02/18 CLIENT APPROVAL JB
p: 0411710320 e: [email protected]
B 5/03/18 OPW APPROVAL JB
61 ELANDA STREET Claire + Wade Jenner MOOD BOARD OPW C DA4
landscape architecture & design studio C 5/06/18 OPW APPROVAL AMENDMENTS JB SUNSHINE BEACH, Q, 4567 PROJECT No 17333
L A R C C O L L E C T I V E
Page 5
1 CORrub
6 DIAblu 1 DICant
3 ISOnod 9 MYOpar
2 CARgra 3 ISOnod
2 CORrub 12 LOMlim 7 METtho
21 ZOYten under
1 CUPana 5 FICpum to wall 7 LIReve 8 DIAblu
9 APTcor under
5 TEChil to trellis
5 LOMblu
5 CARgra
9 ZOYten 7 LIRstr 1 PANuti
5 LOMblu 6 DIAblu 9 BANspi
9 CAS C.I. 4 LIReve 5 ACMsmi
6 JUNusi
5 LOMlim 7 WESjer
5 ISOnod 7 LOMblu
1 XANjoh
12 LIReve 15 CAS C.I. 1 BANint
9 LOMblu 9 LOMtro
Lomandra hystrix
9 JUNcon
or equivalent 5 LOMlim
7 WESwyn
6 LOMlim
2 DORpal
7 JUNcon
1 PANuti
4 BANspi 4 ACMsmi
4 CARgra
5 LOMtro
12 LIReve
7 LIRstr
1 BANint 9 ZOYten
6 DIAblu 1 BRArup
12 CAS C.I. 9 LOMblu
3 ISOnod 7 WESjer
5 CAS C.I.
3 ISOnod
12 LOMlim
9 APTcor under 21 ZOYten under 7 LIReve 8 DIAblu 4 LIReve
5 TEChil to trellis 5 FICpum to wall
1 XANjoh 9 MYOpar
2 CARgra 2 CORrub 7 METtho
6 DIAblu
-
NOOSA COUNCIL
APPROVED PLAN
OPW17/0225.02 24 JUL 2018
N 1/10 station st - bangalow - nsw - 2479 ISSUE DATE DESCRIPTION by PROJECT CLIENT DRAWING NAME PHASE REV SCALE
ISSUE DATE SUBJECT poDRAWN
box 188 - new farm - qld - 4005 NOTE DRAWING TITLE PROJECT TITLE DRAWN DATE CLIENT
A 26/02/18 CLIENT APPROVAL JB JBC 26.09.16
A 26.09.16 FOR TENDER
p: 0411710320
JB
e: [email protected]
B
Do not scale from drawings.
5/03/18
Dimensions OPWonAPPROVAL
are to be checked site JB
61 ELANDA STREET PLANTING
Claire + Wade Jenner PLANITNG PLAN LOT
OPW1010 1:100 @ A3 DA5
P.O Box 188 prior to onsite work commencing with 0 1 2 5m DESIGN JOB NO.
L A R C C O L L E C T I V E
landscape architecture & design studio
New Farm Q. 4005 C
any discrepancies to be brought to the
5/06/18
attention of the author.OPW
ElectronicAPPROVAL AMENDMENTS
drawings are uncontrolled documents
JB SUNSHINE BEACH, Q, 4567
SCHEDULE Ground Floor DISPLAY HOME PROJECT
JBNo 17333
16202-B
0411 710 320 and are issued for information only.
Any dimensions not nominated must be
referred to the Landscape Architect for
Scale: 1:100@A3 CHECK DRAWING No ISSUE
Page 6
-
NOOSA COUNCIL
APPROVED PLAN
OPW17/0225.02 24 JUL 2018
6 APTcor PLANT SCHEDULE
9 CAS C.I.
21 CARgla TREES
Code Botanical Name Common Name Pot Size Staked Size Qty
Banksia integrifolia 100L 2m H
BANint Coast Banksia Y 2
1m W min
BRArup Brachychiton rupestris 200L 2m H
Bottle Tree Y 1
1m W min
12 CAS C.I. 100L 1.5m H
CUPana Cupaniopsis anacardiodes Tuckeroo Y 1
1m W min
9 CAS C.I.
PANped Pandanus pedunculatum Screw pine 400L min 2.5m H
5 SENcha Y 1
2m W min
7 JUNcon Pandanus Red Edge Red Edge 200L min 2m H
PANuti Y 2
1.5m W min
1 PANped SCREENING SHRUBS
Code Botanical Name Common Name Pot Size Staked Spacing Qty
15 LOMblu ACMsmi Acmena smithii 'Minor' Dwarf LIly Pilly 200mm N 1000 9
METtho Metrosiderous thomasii NZ Christmas Bush 200mm N 1000 14
3 DORpal SMALL & SCULTPURAL 4SHRUBS
BANspi
12 LIReve
Code Botanical Name Common Name Pot Size Staked Spacing Qty
CARgra Carrissa grandilfora Desert Star 200mm N 1.5/m 13
CORub Cordyline australis 'rubra' Cordyline Rubra 300mm N as shown 5
5 FESgla
DICant Dicksonia antarctica Tree Fern 200mm Y as shown 1
5 LOMtro DORpal Doryanthes palmerii Giant Spear Lily 200mm N as shown 5
WESjer Westringia jerivs gem Jervis Gem 200mm N 1.5/m 14
WESwyn Westringia wynabbie gem Wynabiie Gem 200mm N 1.5/m 7
PLANT SCHEDULE XANjoh Xanthorrea johnsonii Grass Tree 300mm N as shown 2
TREES GRASSES, GROUNDCOVERS + CREEPERS
Code Botanical Name Common Name Pot Size Staked Size Qty Code Botanical Name Common Name Pot Size Staked Density Qty
100L 2m H APTcor Aptenia cordifolia Baby Sunrose 75mm N 4/m 24
BANint Banksia integrifolia Coast Banksia Y 2
1m W min BANspi Banksia spinulosa DWARF Candle Stick 140mm N 3/m 17
BRArup Brachychiton rupestris 200L 2m H CAS C.I. Casuarina glauca 'Cousin It' Cousin It 140mm N 3/m 71
Bottle Tree Y 1
1m W min
100L 1.5m H
CARgla Carprobrotus glaucecens Pig Face 100mm N 2.5/m 21
CUPana Cupaniopsis anacardiodes Tuckeroo Y 1
1m W min DIAblu Dianella Cassa Blue Cassa Blue 140mm N 3/m 40
PANped Pandanus pedunculatum Screw pine 400L min 2.5m H FESgla Festuca glauca Blue Fescue 140mm N 4/m 5
Y 1
2m W min
ISOnod Isolepsis nodosa Knobby Club Rush 75mm N 4/m 17
Pandanus Red Edge Red Edge 200L min 2m H
ISSUE DATE PANuti
SUBJECT DRAWN NOTE Y 2 TEChil Tecmanthe
DRAWINGhillii
TITLE Fraser Island Creeper PROJECT
140mm
TITLE Trained
DRAWN 1/m
DATE 10 CLIENT
1.5m W min
Juniperus confertus Shore juniper JB 26.09.1623
A 26.09.16
SCREENING SHRUBS
FOR TENDER JB Do not scale from drawings.
Dimensions are to be checked on site
JUNcon PLANTING LOT100mm
1010 N 3/m
P.O Box 188 0 1 2 5m Liriope 'evergreen giant' Evergreen Giant N DESIGN JOB NO. 46
prior to onsite work commencing with
LIReve 140mm 3/m
Code Botanical Name Common
New Farm Q. 4005 Name Pot Size
any discrepancies to be brought to the
attention of the author. Electronic Staked Spacing Qty PLAN DISPLAY HOME JB 16202-B
0411 710 320
drawings are uncontrolled documents
and are issued for information only. LIRstr Liriope 'stripey white' Stripey White 140mm N 3/m 14
ACMsmi Acmena smithii 'Minor' Dwarf LIly Pilly 200mm
Any dimensions not nominated must be N 1000
Scale: 1:100@A3 9 CHECK DRAWING No ISSUE
[email protected] referred to the Landscape Architect for
confirmation. LOMblu Lomandra 'Blue RIdge' Blue Ridge 140mm N LJ 3/m
L2.02 50 A
METtho Metrosiderous thomasii NZ Christmas Bush 200mm N 1000 14
LOMlim Lomandra 'Lime Tuff' Lime Tuff 140mm N 3/m 40
SMALL & SCULTPURAL SHRUBS LOMtro Lomandra 'Tropic Belle' Tropic Belle 140mm N 3/m 19
Code Botanical Name Common Name Pot Size Staked Spacing Qty MYOpar Myoprum parvifolium Creeping booblia 140mm N 4/m 18
CARgra Carrissa grandilfora Desert Star 200mm N 1.5/m 13 SENcha Senecio chalk stick Chalk Sticks 100mm N 4/m 5
CORub Cordyline australis 'rubra' Cordyline Rubra 300mm N as shown 5 ZOYten Zoysia tenufolia Korean Carpet Grass 100mm N 6/m 60
DICant Dicksonia antarctica Tree Fern 200mm Y as shown 1
DORpal Doryanthes palmerii Giant Spear Lily 200mm N as shown 5
WESjer Westringia jerivs gem Jervis Gem 200mm N 1.5/m 14
WESwyn Westringia wynabbie gem Wynabiie Gem 200mm N 1.5/m 7
XANjoh Xanthorrea johnsonii Grass Tree 300mm N as shown 2
GRASSES, GROUNDCOVERS + CREEPERS
N Code 1/10 stationBotanical Name- nsw - Common Name Pot Size Staked Density Qty
st - bangalow 2479 ISSUE DATE DESCRIPTION by PROJECT CLIENT DRAWING NAME PHASE REV SCALE
APTcor po box Aptenia
188 - cordifolia
new farm - qld - Baby Sunrose
4005 75mm N 4/m 24
A 26/02/18 CLIENT APPROVAL JB
BANspi
p: 0411710320 e: [email protected]
Banksia spinulosa DWARF CandleBStick 5/03/18 OPW
140mm
APPROVAL N 3/m
JB 17 61 ELANDA STREET Claire + Wade Jenner PLANTING PLAN OPW C 1:100 @ A3 DA6
Casuarina
CAS C.I.landscape glauca 'Cousin
architecture & It'
design studio Cousin
C It 5/06/18 OPW 140mm N
APPROVAL AMENDMENTS 3/m
JB 71 SUNSHINE BEACH, Q, 4567 roof top PROJECT No 17333
L A R C C O L L E C T I V E
CARgla Carprobrotus glaucecens Pig Face 100mm N 2.5/m 21
Page 7
PRELIMINARY LANDSCAPE SPECIFICATION NOTES All turf ares to be cultivated to a minimum of 200mm before turf installation
MULCH AND PLANTING AS SPECIFIED.
EXTENT OF LANDSCAPE WORKS 8. STREETSCAPE LONGITUDINAL EDGING: 100x19mm.
Landscape Areas Generally Construct all as per NSC standard Details;
FIX TO STAKES WITH
2 No. 40mm GALV. NAILS.
Streetscape Works
Soft Podium Landscape 9. TURF JOINER TIMBER:75x15x450mm LONG. JOIN TIMBER
Planting to Podium Garden Beds Turf to be A GRADE Soft Leaf Buffalo on min 100mm topsoil EDGES AT STAKE WITH NAIL FIXED TO EDGING.
Trellis
Irrigation (Plans by others) 10. IRRIGATION TURF AS SPECIFIED
Establishment and Maintenance All Irrigation to be designed and documented by a suitably qualified
consultant
ALL LANDSCAPE AREAS SHOULD BE TREATED GENERALLY IN Allow for drip irrigation to all garden areas and pop up to turf areas TOPSOIL AS SPECIFIED
ACCORDANCE WITH NOOSA SHIRE COUNCIL's Landscape Works System to be fully automated, coordinate location of controller on site STAKES: 42x42x450mm LONG AT
guidelines. MAX 1500mm CCS. ENSURE STAKES ARE PLACED
The following information is provided as a summary only and should be used 11. ESTABLISHMENT AND MAINTENANCE ON GARDEN SIDE.
for general information purposes only. General: Establish and maintain works following the issue of the Certificate CULTIVATE SUBGRADE AS SPECIFIED
of Practical Completion by the Landscape Superintendent. Maintain accepted
1. GENERAL horticultural practices, as well as rectifying defects that become apparent in EXISTING SUBGRADE
Scope of works as shown on drawings. All work to be carried out by suitably the works under normal use.
qualified tradesmen with experience in Landscape Construction works. All SECTION VIEW NOTES:
planting works are to be carried out by a registered QBCC Licensed Planting Areas: FOR TIMBER GRADING:
Landscape Contractor. A flush durable edge is to be provided between all The Landscape Contractor shall throughout the planting establishment /
REFER LANDSCAPE
SPECIFICATION.
garden beds and turfed areas, areas of other loose material and under all maintenance periods continue to carry out current works of a maintenance FOR TIGHT RADII: PARTIALLY SAW
fences on common boundaries and road frontages. nature including but not limited to watering, weeding, fertilising, pest and RELIEF CUT TO EDGE TO ALLOW
disease and weed control, planting replacements, pruning and the like.The 15 FOR EASIER BENDING TO PEG.
2. MULCH watering program is to be as follows: LONGITUDINAL EDGING: 100x19mm.
Standards: To AS4454-2003 'Compost, soil conditioners and mulches'. Week 1-2: 3 times per week
FIX TO STAKES WITH
2 No. 40mm GALV. NAILS.
Ensure Mulch is free from deletrious matter, fungi and disease. Mulch shall Week 3-6: 2 times per week
finish 25mm below adjacent surfaces Week 7-12: 1 time per week
STAKES: 42x42x450mm LONG AT
MAX 1500mm CCS. ENSURE STAKES
Mulch type: 150mm Forest Mulch (no fines) to all garden beds unless ARE PLACED ON GARDEN SIDE.
400
otherwise stated. Replace any plant that has been planted by the contractor, which dies from
any cause during the planting establishment period. Plant replacement shall JOINER TIMBER:75x15x450mm LONG.
JOIN TIMBER EDGES AT STAKE WITH
3. TOPSOIL be of equivalent size and species as detailed in the plant schedule. Weed NAIL FIXED TO EDGING.
Imported Topsoil. banks, tree planting sites, seeded and grassed areas regularly and as
Standards: To AS 4419-2003 'Soils for landscaping and garden use'. necessary to leave in a clean and tidy state. 15
Ensure modified topsoil is free from stones, sticks, roots, rubbish and PLAN VIEW
material toxic to plant growth.
Modified topsoil shall have a friable structure with good drainage and high
Mowing Regime: 01 GARDEN EDGE
Turf areas should be kept neatly trimmed to a maximum height of 20mm
organic content.
Minimum depths -
above the sod layer. Mowing should be carried out at regular intervals to
ensure the turf is kept at the desirable level. The mowing regime should
SCALE 1:20 @ a3
To garden beds - as detailed, miniumum 400mm depth. respond to weather conditions and it is expected that areas will need to be
To tree holes and pits - 1.5 x rootball diameter and 2 x rootball depth maintained on a weekly basis during the growing season and either
To podium; refer specific detail and podium soil mix fortnightly or monthly during dormant periods depending upon the prevailing
weather conditions.
4. PLANTING Removal of Weeds, Debris and Rubbish:
All garden beds to be prepared as detailed with drainage to PDO as The Contractor shall be responsible for ensuring that all site rubbish
required; connections to site stormwater network, refer Hydraulic Engineers including plastic planting pots and bags, are removed by environmentally
Drawings as required approved practices from all areas.
5. TREE PLANTING Final Inspection:
Supply and place in accordance with Planting Plans. At the completion of the establishment / maintenance period, the final
Refer to Tree Planting Detail for appropriate planting method. inspection shall be held. If all or certain portions of the work are not
Finish Mulch level to be min25mm below all adjoining surfaces and edges. acceptable under the terms and intent of the drawings and specifications, the
Staking: all trees shall be staked as per detail. establishment / maintenance period for the works shall be extended until the TURF AS SPECIFIED
defects work have been corrected and the work accepted by the Landscape 100MM IMPORTED TOPSOIL AS SPECIFIED.
6. SHRUBS AND GROUNDCOVERS Architect.
Shrubs and groundcovers shall provide complete coverage of planting areas
at maturity.
Minimum sizes: 12. IMPORTANT NOTES
Shrubs - 200mm stock All items not listed within this specification to be constructed and
Groundcovers - 75mm stock installed as per Landscape Works Construction Details
Verify location of all services on site prior to commencement of any
7. CULTIVATION works.
All garden areas to be cultivated to a minimum of 500mm before garden Refer to other consultants plans as necessary.
installation Remove all unwanted building material from site.
All turf ares to be cultivated to a minimum of 200mm before turf installation All take offs & quantities to be checked by landscape contractor.
02 TURF
SCALE 1:20 @ a3
-
NOOSA COUNCIL
APPROVED PLAN
OPW17/0225.02 24 JUL 2018
ISSUE DATE SUBJECT DRAWN NOTE DRAWING TITLE PROJECT TITLE DRAWN DATE CLIENT
1/10 station st - bangalow - nsw - 2479 ISSUE DoDATE DESCRIPTION by PROJECT CLIENT DRAWING NAME PHASE JB
REV SCALE26.09.16
A 26.09.16 FOR TENDER po boxJB 188 - new farm - qld - 4005
not scale from drawings.
Dimensions are to be checked on site PLANTING LOT 1010
P.O Box 188
A 26/02/18
prior to onsite workCLIENT
commencing APPROVAL
with JB DESIGN JOB NO.
p: 0411710320 e: [email protected]
New Farm Q. 4005B
any discrepancies to be brought to the
attention of the author. Electronic
5/03/18
drawings OPWdocuments
are uncontrolled APPROVAL JB
61 ELANDA STREET Claire + Wade Jenner
PLAN SPEC NPOTES DISPLAY
OPW HOME C
JB 16202-B DA7
landscape architecture & 0411 studio
design 710 320 and are issued for information only.
SUNSHINE BEACH, Q, 4567 PROJECTCHECK
No 17333DRAWING No ISSUE
C 5/06/18
Any dimensions notOPW
nominated APPROVAL
must be AMENDMENTS JB
L A R C C O L L E C T I V E
[email protected] referred to the Landscape Architect for
confirmation. LJ L2.03 A
Page 8
-
NOOSA COUNCIL
les d
du a te
he ic
sc ind
APPROVED PLAN
nt a s
pla g
in acin
OPW17/0225.02 24 JUL 2018
Sp
PLANTER BOX DRAIN WITH
spacing
½ plant
FALL FALL INSPECTION RISER & CAP
REFER HYDRAULIC ENGINEER
FOR DETAILS
Plan view
BLOCKWORK PLANTER 75mm ORGANIC MULCH
WALL, BY BUILDER LAYER AS SPECIFIED
BLOCKWORK PLANTER
WALL, BY BUILDER
CONTAINERISED PLANT STOCK AS PER PLANT SCHEDULE
STAKE IF SPECIFIED IN PLANT SCHEDULE. WATERPROOF MEMBRANE WATERPROOF MEMBRANE
BY BUILDER BY BUILDER
DEPTH IMPORTED PODIUM SOIL
MAINTAIN 50mm SEPARATION BETWEEN VAIRES
MULCH AND STEM OF PLANT.
MIX AS SPECIFIED TO
MAKE UP REQUIRED
LEVELS
MULCH LAYER AS SPECIFIED 30MM DRAINAGE CELL WITH
GEOFABRIC OVER AS SPECIFIED; TO
TOPSOIL AS SPECIFIED. PLACE AND LIGHTLY COMPACT BE PLACED OVER GARDEN AREAS
TOPSOIL IN LAYERS TO PREVENT AIR POCKETS. ONLY ON PODIUM SLAB; RETURN
FORM SHALLOW DEPRESSION IN SOIL AROUND TOP DRAINAGE CELL VERTICALLY UP
OF ROOTBALL TO IMPROVE WATER RETENTION TO PLANT. INTERNAL FACE OF WALL, FINISH
50 50
JUST UNDER MULCH LAYER
BLINDING LAYER TO ACHIEVE
PLACE SLOW RELEASE FERTILISER INTERNAL PLANTER FALLS
AS SPECIFIED AROUND ROOTBALL.
REFER HYDRAULIC ENGINEER DETAILS
FOR
PLANTER DRAINAGE
01 75-140mm PLANT STOCK PLANTING 02 TYPICAL PODIUM PLANTER DETAIL
SCALE 1:20 @ a3 SCALE 1:40 @ a3
NOTE
1. PIT FOR TREE PLANTING TO BE 2 X
THE WIDTH OF THE ROOTBALL.
LIGHTLY COMPACT IMPORTED SOILS
UNDER
2. REFER TO PLANTING PLANS FOR
NOTE: VERIFY LOCATION OF SERVICES PLANTING NUMBERS AND DENSITIES.
PRIOR TO EXCAVATION OF TREE HOLE. 3. INSTALL FERTILISER TO RATES AS
RECOMMENDED BY MANUFACTURER.
PROPOSED TREE AS SPECIFIED
(REFER TO PLANT SCHEDULE)
ENSURE TRUNK IS VERTICAL
TREE STOCK AS SCHEDULED
CONTAINERISED PLANT STOCK AS PER PLANT SCHEDULE
STAKE IF SPECIFIED IN PLANT SCHEDULE. ORGANIC MULCH AS SPECIFIED (KEEP 50MM
STAKE TREES AS PER PLANT SCHEDULE AND AS SPECIFIED. DRIVE CLEAR OF BASE OF TRUNK). MULCH TO BE
MAINTAIN 50mm SEPARATION BETWEEN INTO GROUND WELL AWAY FROM ROOTBALL OF TREE. TIE AS INSTALLED min 25MM BELOW ADJOINING FINISHED
MULCH AND STEM OF PLANT. SURFACE LEVEL FINISHED
SPECIFIED IN A FIGURE EIGHT MANNER AROUND TRUNK.
MULCH LAYER AS SPECIFIED 600mm
SLOW RELEASE FERTILISER AS SPECIFIED min
PLACE SLOW RELEASE FERTILISER AS SPECIFIED AROUND THE
TOPSOIL AS SPECIFIED. PLACE AND LIGHTLY COMPACT ROOTBALL TO MANUFACTURER'S SPECIFICATIONS.
TOPSOIL IN LAYERS TO PREVENT AIR POCKETS. IMPORTED SOILS AS SPECIFIED
FORM SHALLOW DEPRESSION IN SOIL AROUND TOP
OF ROOTBALL TO IMPROVE WATER RETENTION TO PLANT.
MULCH AS SPECIFIED. FINISH MULCH
50 50 FLUSH WITH ADJACENT F.S.L. PODIUM SLAB BY OTHERS ROOTBALL
TEASE OUT ROOTBALL PRIOR TO PLANTING. TOPSOIL DEPTH AS SPECIFIED TO
2 x ROOTBALL (2Y)
400lt
PLACE SLOW RELEASE FERTILISER AS SURROUNDING PLANTING BEDS
Y
SPECIFIED AROUND ROOTBALL.
CULTIVATE EXISTING SUBGRADE
AS SPECIFIED EXCAVATE THE HOLE TWICE THE
X WIDTH (2 X) AND TWICE THE DEPTH (2 Y). FILL WITH TOPSOIL MIX AS
SPECIFIED TO SUPPORT TREE GROWTH.
CULTIVATE SIDES & BASE OF PLANTING HOLE.
2 x ROOTBALL (2X)
03 200-400mm PLANT STOCK PLANTING 04 45L-200L PLANT STOCK PLANTING 05 PODIUM TREE PLANTING
SCALE 1:20 @ a3 SCALE 1:40 @ a3 SCALE 1:40 @ a3
ISSUE DATE SUBJECT DRAWN
1/10 station st - bangalow - nsw - 2479 ISSUE NOTE
DATE DESCRIPTION by PROJECT DRAWING TITLE
CLIENT DRAWING NAME PROJECT
PHASE TITLE DRAWN
REV DATE
SCALE CLIENT
JB 26.09.16
PLANTING LOT 1010
po box 188 - new farm - qld - 4005
A 26.09.16 FOR TENDER JB Do not scale from drawings.
A 26/02/18 CLIENT APPROVAL JB
DA8
Dimensions are to be checked on site
p: 0411710320
P.O Box 188
e: [email protected] prior to onsite work commencing with 61 ELANDA STREET Claire + Wade Jenner DETAILS OPW DESIGN
C JOB NO.
as shown
landscape architecture &
New Farm Q. 4005 B
design studio
any discrepancies to be brought to the
5/03/18 OPW APPROVAL
attention of the author. Electronic
drawings are uncontrolled documents
JB
PLAN DISPLAY HOME JB 16202-B
0411 710 320 C 5/06/18 OPW APPROVAL AMENDMENTS
and are issued for information only. JB SUNSHINE BEACH, Q, 4567 PROJECT No 17333
DRAWING No ISSUE
L A R C C O L L E C T I V E
[email protected]
Any dimensions not nominated must be
CHECK
LJ L2.04 A
referred to the Landscape Architect for
confirmation.
Used in these records
Approved Plans OPW17-0225.02.pdfRelated documentApplication case desk ↗
About this file
- File size
- 4.5 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.