Log in to see the plans as drawnPERFORMANCE OUTCOMES ACCEPTABLE OUTCOMES PROPOSED SOLUTION
Impact on Ecologically Important Areas
PO2 No acceptable outcome provided No vegetation clearing is required to facilitate the
Bushfire mitigation measures do not bushfire mitigation measures detailed in this report
adversely impact on: which could not already legally be undertaken as
a) biodiversity values, connectivity and exempt clearing available under the essential
ecosystem functioning; and management exemption prescribed under the Planning
Regulation 2017.
b) the long term physical integrity of
waterways, wetland and areas of native
vegetation.
Water Supply for Fire Fighting Purposes
PO3 AO3.1 The development complies with AO3.2.
Development provides an adequate Premises are connected to the reticulated water supply.
The site will not be connected to a reticulated water
water supply for firefighting purpose
supply. A permanent dam with volume far in excess of
which is reliable, safely located and freely Editor's note—For reconfiguring a lot, water supply
5,000 litres is located approximately 160m to the east
accessible. needs to provide for a minimum flow and pressure of
of the cottage as a suitable emergency water supply.
10 litres a second at 200kPa at all times for firefighting
purposes.
OR
AO3.2
Where there is no available reticulated water supply,
the premises has:
a) an accessible dam, swimming pool or water tank
available for firefighting purposes with an onsite water
volume of not less than 5,000 litres; and
JULY 2022 BUSHFIRE HAZARD ASSESSMENT & MANAGEMENT PLAN Page: 31