Log in to see the plans as drawnPERFORMANCE OUTCOMES ACCEPTABLE OUTCOMES PROPOSED SOLUTION
Hazardous Material
PO5 AO5 PO5 - The proposed development does not involve the
Public safety and the environment are not Hazardous materials are not manufactured or stored in manufacture or storage of hazardous materials in bulk.
adversely affected by the impacts of bulk in a bushfire hazard area.
bushfire on hazardous materials
manufacturing or storing in bulk.
Access and Evacuation Routes
PO6 AO6.1 PO6 - N/A – No new roads are proposed. The northern
Roads provide for easy and safe The road layout provides for through-roads and avoids primary driveway access is approximately 460m long.
evacuation of residents of premises and cul-de-sacs and dead-end roads. The northern access would direct occupants to an area
access by emergency services. OR of low hazard vegetation (Stratford Park Estate) in an
AO6.2 easterly and northerly direction and away from the
The development has a perimeter road reserve with a likely direction of a fire front to the west of the site. An
minimum width of 20 metres and maximum gradient of additional longer evacuation/access route is present to
12.5%. the west of the site which would direct occupants to
OR the south-west in the less likely event that a fire front
AO6.3 was present to the north or east of the site.
Cul-de-sacs or no-through roads are provided with fire
The development site is on a gentle/low grade and the
trails or access easements, which are capable of being
cottage is provided with sufficient cleared area to
navigated by conventional vehicles and which link to
provide adequate turning space for fire-fighting
through roads.
appliances. Whilst the development cannot comply
with the 60m distance as recommended in Assessment
AO6.4
Benchmark 4 of the SPP, it is considered acceptable in
Safe access and egress is available at all times to all of
this instance in consideration of all of the other bushfire
the development for emergency vehicles and
management measures implemented.
personnel.
AO6.5
JULY 2022 BUSHFIRE HAZARD ASSESSMENT & MANAGEMENT PLAN Page: 33