Original source · versioned page text
Architecturals 08.01.21
Original PDF page 5, section 1. The text section number identifies this passage in the reader.
27,730 GENERAL NOTES
1,670 5,040 9,030 11,990
1. PROVIDE COLD WATER CONNECTION & G.P.O.
220 4,600 220 9,030 650 350 4,275 350 4,275 350 1,740 TO DISHWASHER SPACE.
2. VENTILATION TO WC TO BE AN EXHAUST FAN
220 1,580 90 4,600 220 220 1,970 70 9,510 220 IN ACCORDANCE WITH BCA-F4.5 & AS-1668.2
3. THE NUMBER OF DOORS AND WIDTH OF DOORS
220 1,580 90 3,580 70 950 70 3,000 70 3,000 70 2,120 70 1,000 70 1,970 70 WILL BE DETERMINED BY THE CABINETMAKER TO
70 OPTIMIZE THE FUNCTIONALITY OF THE CABINETRY.
1,670 220 810 70 1,800 70 830 950 70 3,000 70 1,930 70 1,000 70 2,120 70 1,000 70 1,870 70 9,610 220 EXPANSION JOINTS
EJ = Expansion joint location for ceiling & floor
D.P D.P tiles.
lintel lintel 350.sq brick piers (3)
CONSTRUCTION NOTES :
350
350
1. EXTERNAL WALLS = 220mm (110mm BRICK,
40mm CAVITY, 70mm FRAME)
2,290
2. N3 WIND DESIGN SPEED NOMINATED.
3. WC DOOR TO HAVE EXTERNAL REMOVABLE
AL FRESCO
3,700
3,650
3,650
3,650
HINGES IN ACCORDANCE WITH BCA-3.8.3.3.
3,760
lintel
lintel
plaster lined ceiling
3,300
D.P
21-30 SD
ARTICULATION JOINTS 50 350 4,275 350 4,275 350 50
5,200
AJ = Articulation joint location nominated on drawings.
220
220
9,700
4,850
Builder to provide extra Articuation joints over & above
21-09DH
1,470
rak what is nominated on drawings where necessary to
ceil ed 21-62 BI PARTING
split system
HC
X
ing comply with the Building Code of Australia, Engineers
2.5kw06-21SW
on wall bracket
06-24SW STACKER DOORS 18-06DH
structural design requirements, soil report
gas bottles by owner
selected
ac unit
recomendations and site classification requirements 1,130 900
220
220
220
220
220
220
bulkhead
220
frz
1,550
900
MASTER BEDROOM over ohcs
18-09DH
carpet
4,660
18-06DH 18-06DH D.P
21-18SW OBS
dw
06-24SW
range with canopy RH
900mm freestanding
ohc
BUTLERS PANTRY
300 wide b"bar ohang
220
220
220
220
220
freestanding
open shelving
mw
6,510
towel
4,720
rail
1560 bath sink
W.I.R.
over
4,480
4,480
4,280
9.4kw split system
under eave
FAMILY/DINING
5,150
TV niche
carpet
6,140
pull out
3,780
shr
2,630
2,000
04-06 NICHE
bin
tiled
820
5,700
5,700
3,000
BED. 2
FG panel
CHILD'S RETREAT smart sink rak
ceil ed
ohc
waste
gsa hot
carpet
system
3,600
ing
ohc
water
tiled 1000 smart
140
450
1800 vanitywaste open
4,700
4,700
70
smart
waste vanity
towel
rail 720 wc
shelving
70 70
1,800 sliders
8,720
roll
18-09DH
900
70
1,000
holder
ohc
900
rak
ref
2,450
720
vanity
600
600
70 70
linen brm ceil ed
530
09-06SW OBS
220
D.P
robe
70
720 820 820 selected ing
wc smart ac unit
shr waste 1,800 sliders 700
70
70
70
70
19,500
19,500
1,030
1,030
roll
holder
04-06 NICHE
70
18-09DH D.P
220
530
linen
70 70
selected
70
820 820 ac unit
70
70
70
70
700 1,800 700
3,400 sliders
4,580
hamper
1,440 CSD
drop in tub/
4,580
1,220
820
21-15 SD
2.5kw split system
bench
ENTRY
on wall bracket
4,120
cupds under
2,800 sliders
2,800 sliders
2,800 sliders
1,820
MEDIA
3,470
3,550
BED. 4 BED. 3 STUDY
3,470
linen
robe
3,000
3,000
3,000
3,000
carpet
robe
wm brm carpet carpet carpet
70 530
70
1,200
70
960
450
220
820
D.P
18-09DH 06-24SW - 2 18-09DH 18-09DH 18-09DH
70
70
70
70
70
D.P D.P D.P D.P
220
70
PORTICO
1,170
MH
lintel
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.