MATERIALS AND FINISHES
CODE DESCRIPTION FINISH FT3 2m Powdercoated Aluminium Screen XXXX
AWN1 Awning Hood Powder Coated Aluminium Surfmist PV1 Feature Driveway Entry Beauford Crazy Pave
AWN2 Awning Hood Powder Coated Aluminium Surfmist RN1 Render Resene Black White
BAL3 Aluminium and Clear glass balustrade Powder Coated Aluminium Surfmist RN2 Render with Sawcuts Concrete Look
BAL4 Solid Balustrade Birch RN3 Render with Sawcuts To Match Surfmist
BAL5 Aluminium and Clear glass balustrade Powder Coated Aluminium Surfmist RN4 Render over cladding Resene Black White
BAL6 Aluminium and Translucent glass balustrade Powder Coated Aluminium Surfmist RN5 Render with Sawcuts over cladding Concrete Look
CLD1 Hardies Oblique XXXX RS1 LYSAGHT Colorbond roof sheet Colorbond Surfmist
CLD2 External Feature Walls - Territory Panel Limed SCN1 Aluminium Batten Screen - angled Powder Coated Aluminium Surfmist
EA CONC Driveway; Exposed Aggregate Concrete Silver Frost SF1 Soffit lining Resene Black White
EG1 Eaves Gutter Stratco Colorbond Surfmist SF2 Soffit lining Pre-finished
EG2 Custom Profile Eaves Gutter Colorbond Surfmist SF3 Soffit lining - Territory Panel Limed
FF1 External Tile Paradise Stone Ivory
FT1 2m High Perimeter Fencing Timber Pailing Resene Black White
FT2 1.4m Screen above Rendered Blockwork XXXX
FT3 2m Powdercoated Aluminium Screen XXXX
U
U
3.4 2.4 1.4
A.4 B.4 C.4 D.4 E.4
TOWNHOUSE 401 TOWNHOUSE 402 TOWNHOUSE 403 TOWNHOUSE 404
TOWNHOUSE 404
BOUNDARY
8M HEIGHT LIMIT
8M HEIGHT LIMIT AT ROOF RIDGE
W.21 W.21
RS1 8M HEIGHT LIMIT
RS1 RS1
EG1 EG1 AT FASCIA
EG1 RN5 EG1
CLD2
RN5 RN5 RN5
2400 WINDOW & 2400 WINDOW &
RN5 W.20 W.20 W.20 W.20
DOOR HEAD HEIGHT DOOR HEAD HEIGHT
W.21 W.21
W.21
UPPER LEVEL UPPER LEVEL RN5 RN5
FFL+14.200 FFL+14.200
EG1 RS1 EG1
EG1 EG1
RN4
CLD2 RN4 RN4 RN4 RN4
2400 WINDOW & 2400 WINDOW &
DOOR HEAD HEIGHT DOOR HEAD HEIGHT
CL CL CL
TERRACE TERRACE TERRACE TERRACE
2,400
W.06 W.06
GROUND LEVEL FFL+11.000 GROUND LEVEL
FFL+10.500 FFL+10.500 AD.04 AD.18 AD.04 AD.18
FINISHED GROUND
FINISHED GROUND
NATURAL GROUND NATURAL GROUND
N BUILDING 4 ELEVATION E BUILDING 4 ELEVATION
- Scale 1:100 - Scale 1:100
U
U
E.4 D.4 C.4 B.4 A.4
1.4 2.4 3.4
TOWNHOUSE 404 TOWNHOUSE 403 TOWNHOUSE 402 TOWNHOUSE 401
TOWNHOUSE 401
BOUNDARY
8M HEIGHT LIMIT 8M HEIGHT LIMIT
RS1 RS1 RS1 RS1
EG1 EG1 EG1 EG1
EG1 RN5 RN5 RN5 CLD2 CLD2
2400 WINDOW & RN5 RN5 RN5
W.20 W.20 W.20 W.20
DOOR HEAD HEIGHT
UPPER LEVEL UPPER LEVEL W.07 W.07 W.07 W.07
FFL+14.200 FFL+14.200
EG1 EG1 RS1 EG1 EG1
EG1
RN4 RN4 CLD2 RN4 RN4 RN4 RN4 RN4 RN4
2400 WINDOW &
DOOR HEAD HEIGHT
W.05
2,400
GROUND LEVEL W.05 W.05 W.05
GROUND LEVEL W.06 W.06
FFL+11.000 D.13 AD.09 AD.09 D.14 D.13 AD.09 AD.09 D.14
FFL+11.000
FFL+10.500
FINISHED DRIVEWAY
NATURAL GROUND
NATURAL GROUND FINISHED GROUND
BUILDING 4 ELEVATION W BUILDING 4 ELEVATION
S - Scale 1:100
- Scale 1:100
Notes:
B L A C K Project: Drawing Title: Project No. Drawn By Drawing No.
Rev Date Description Use figured dimensions in preference to scale. Contact information:
1. These drawings represent a concept design for preliminary cost analysis (MAY 2023) and are NOT FOR CONSTRUCTION Q 30/01/2024 Council Decision Notice Response All dimensions to be varified and checked on
R 4/03/2024 Updated Building Layout Submission site. These designs, drawings, specifications
PO Box 781 Tewantin Q 4565 79 - 83 Eumundi Noosa Road B4 - ELEVATIONS 202327 PT WD.4.06
2. The drawings and diagrams provided herewith are NOT FOR CONSTRUCTION OR BUILDING APPROVAL and to be used for preliminary D&C tendering only. Architect Registration # 5386 QLD
and the copyright thereof are the property of For CAPITAL PRUDENTIAL
Structure & Services coordination has not been undertaken.
S
T
10/04/2024
24/04/2024
UPDATED COUNCIL RFI
Update to Builder
Blackwood and must not be used, retained or W O O D Ph: 0416 037 424
[email protected] 79 - 83 EUMUNDI NOOSA ROAD & 26 Scale Date Project Stage Revision
copied without the written authority of
U 8/11/2024 Roof Revision Issue Blackwood. a r c h i t e c t u r e & d e s i g n www.blackwoodarchitecture.com.au HEADLAND DRIVE, NOOSAVILLE QLD 4566 1:100, 1:1 @ A1 8/11/2024 Design Development U