Council archive · source document
180215 1801 (Mcu) 2 · MCU18/0048
Attached to the e-mail Detached House - MCU18/0048.
Original PDF page 13, section 1. The text section number identifies this passage in the reader.
design group
1 2 3 4 5 6 7 building design + interior design
1,390 4,490 2,425 4,085 500 1,470
EXT. FINISHES LEGEND
Open pergola inside
AS aluminium screen.
side setback aluminium louvres, refer sched.
Roof/ wall inside AL
1.5m side setback
FFL 41.100 FFL 41.100
ASD aluminium sliding door.
ROOF ROOF AFD aluminium framed door.
HALL AFW aluminium framed window.
LIVING / DECK
BA sun control battens, refer detail.
BAL1 balustrade-(no refers to type).
BLK masonry blockwork.
FFL 38.460 FFL 38.460 C carpet
UPPER LEVEL HALL BATH UPPER LEVEL
LIVING 2 CS concrete slab.
DP down pipe.
DS driveway slab.
FCA fibre cement awning.
FC fibre cement external cladding.
FFL 35.400 FFL 35.400 FG fascia gutter.
MAIN LEVEL MAIN LEVEL FT1 floor tile - (no refers to type).
fire fireplace
flue flue kit
GS garage slab.
WEST ELEVATION HWS hot water service.
SCALE 1:100 @ A3 HR handrail.
LPG LPG gas bottle.
NGL NRG board
MR1 metal roof - (no refers to type).
NGL natural ground line.
PF compliant pool fencing
PW parapet wall.
PS patio slab.
PV photovoltaic cells.
RWT rain water tank.
SBJ silicone butt jointed glass.
SP structural post, refer engineer.
SF structural footing, refer engineer.
TIM timber cladding.
TD timber deck.
TF timber floor.
MCU Material change of use
issue issue / amendment
15.02.18 SF. LF. AB. NB.
issue date drawn by
client
Cori & Andrew McGuinness
project
1801 McGuinness house
location
7 Arakoon Cres Sunshine Beach Q 4567
WEST ELEVATION
Lee Foster • director Scott Falconer • director
p - 0424 620 247 p - 0431 267 157
design group e - [email protected] e - [email protected]
the aboda design group trust Level 2 1794 David Low Way Coolum Beach,
ABN 56 266 884 746 Q. 4573. PO box 2449 Noosa Heads Q 4567
t/a aboda design group • BSA License -150580097 • www.aboda.com.au
• This drawing is to be read in conjunction with engineers drawings & reports • Construction
to comply with all relevant SAA & NCC Codes & standard Bldg By-law 1975 & as amended •
Copyright for design & drawings remain the property of the authors • Verify all dimensions on
site prior to commencement of any works • These drawings are not to be used for scaling.
WEST ELEVATION
scale as shown @ A3 issue
drawing no.
3D PERSPECTIVE
WD.504 MCU
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
180215 1801 (MCU) 2.pdfRelated documentApplication case desk ↗
About this file
- File size
- 6.6 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.