Original source · versioned page text
16-003302-3101(A)
From the archive 16-003302- Proposed Stage 3 Plans.zip, inside Operational Works Application OPW16/0345. File date in the archive: 2016-12-23 11:13.
DocuSign Envelope ID: 69D49415-881C-4D35-BC9B-DE8DA1B3BB93
LEGEND
ROAD WORKS AND DRAINAGE EARTHWORKS WATER SUPPLY
DESCRIPTION PROPOSED EXISTING FUTURE DESCRIPTION PROPOSED EXISTING FUTURE DESCRIPTION PROPOSED EXISTING
600Ø FINISH SLAB LEVEL FL 101.15
STORMWATER PIPELINE FL 4.35 WATER SUPPLY 150Ø uPVC
BULK EARTHWORKS LEVEL BE 101.00
EARTHWORK LEVELS .643 .082 WATER SUPPLY 100Ø uPVC
ROOFWATER CONNECTION PIPE 100 106
STORMWATER DRAINAGE PITS CONTOURS 5.6 5.4 WATER SUPPLY 63Ø PE100
SANITARY SERVICES BATTER SANITARY DRAINAGE
WATER SUPPLY STORMWATER PIPELINE STORMWATER DRAINAGE
UNDERGROUND ELECTRICAL STORMWATER DRAINAGE PITS WATER SERVICE POINT (METER)
CONCRETE PAVEMENT
WATER RETICULATION HIGH POINT HP HP
(REFER DRG 3302 & 3303 FOR DETAILS)
CARAVAN PARKING GRAVEL AREA
(REFER DRG 3302 & 3303 FOR DETAILS) SEWER RETICULATION LOW POINT LP LP
FH FH
CARAVAN WASHDOWN BAY UNDERGROUND ELECTRICAL FIRE HYDRANT (DUAL OUTLET PILLAR)
ROCK ARMOURING TABLE DRAIN/SWALE SLUICE VALVE
BATTERS BIOPOD ROCK RETAINING WALL SCOUR VALVE
CONTOURS 5.6 5.4 CONCRETE SLEEPER RETAINING WALL TEST/CLORINATION POINT
TABLE DRAIN/SWALE SAFETY FENCE
STORMWATER CATCHMENT NAME G32 G44 BOUNDARY FENCE (BY OTHERS) SANITARY DRAINAGE
STORMWATER CATCHMENT BOUNDARY DESCRIPTION PROPOSED EXISTING
CUT
SANITARY DRAINAGE 150Ø DN
SAFETY FENCE
FILL
WATER SUPPLY
BOUNDARY FENCE (BY OTHERS)
STORMWATER DRAINAGE
STAGE BOUNDARY
EROSION AND SEDIMENT CONTROL ALLOTMENT CONTROL
DESCRIPTION PROPOSED EXISTING FUTURE 101.705
POINT FINISH SURFACE LEVEL
BIOPOD ROCK RETAINING WALL
FINISH SLAB LEVEL FL 101.15
BULK EARTHWORKS LEVEL BE 101.00 FL 4.35
UNDERGROUND ELECTRICITY
CONCRETE SLEEPER RETAINING WALL
CUT SEWER MANHOLE NUMBER 1 E
BARRIER KERB ONLY SEWER LINE NUMBER 16 101
REFER TO DRG 3300 FOR DETAILS
FILL
BIOPOD FILTER AREA SEDIMENT FENCE (OR AS DIRECTED BY
SITE SUPERINTENDENT
PROPOSED LEVELS 100.643
DIRTY WATER DIVERSION DRAIN ALIGNMENT
IS INDICATIVE ONLY - CONTRACTOR TO
ENSURE DIRTY WATER SITE RUN-OFF IS
DIRECTED TO SEDIMENT TRENCH THROUGH
ALL PHASES OF CONSTRUCTION
CLEAN WATER DIVERSION DRAIN ALIGNMENT IS
INDICATIVE ONLY - CONTRACTOR TO ENSURE
CLEAN WATER IS DIVERTED THROUGH SITE
DURING ALL PHASES OF CONSTRUCTION
CONCRETE SLEEPER RETAINING WALL
ROCK BOULDER RETAINING WALL
ENTRY/EXIT POINT
SPILL THROUGH WEIR LOCATION (INDICATIVE)
GULLY INLET PROTECTION
N.S.C. REF NO. MCU15/0111 & REC15/0031
DRAWN STATUS SCALE CLIENT PROJECT DRAWING TITLE
REVISION DATE ISSUE DETAILS DRAWN DESIGN
A 21.12.16 ORIGINAL ISSUE HT BF FOR APPROVAL PALM LAKE WORKS PTY LTD PALM LAKE RESORT
2 NOT FOR CONSTRUCTION STAGE 3 LEGEND
3
4 DESIGN APPROVED 19 TRADING POST ROAD - COOROY
5 ANDREW McPAIL RPEQ 6921 PROJECT No. DRAWING No. REVISION
6 DISCLAIMER
7
C 2015 www.calibreconsulting.co
ALL DIMENSIONS TO BE CHECKED ON SITE BY CONTRACTOR PRIOR TO
CONSTRUCTION. USE WRITTEN DIMENSIONS ONLY, DO NOT SCALE.
16-003302 3101 A
8 FOR & ON BEHALF OF CALIBRE CONSULTING (QLD) PTY LTD