                 17.    All landscape works must be established and maintained in accordance with the
                        approved design for the life of the development, and in a manner that ensures healthy,
                        sustained and vigorous plant growth. All plant material must be allowed to grow to full
                        form and be refurbished when its life expectancy is reached.
                 18.    All planting areas on the eaves must be planted and maintained at all times, with
                        replacement planting undertaken promptly where plants fail or do not have a healthy
                        and vigorous growth.
                        Coastal Protection
                 19.    External colours and finishes must be of muted/environmental tones that blend with the
                        natural environment and low-reflective roofing and cladding materials.
                 20.    Any fencing to the eastern boundary must not exceed 1.2 metres in height, be of open
                        construction, constructed of light weight materials (eg. timber) and be dark in colour to
                        blend with the natural landscape.
                        Site Access and Driveways
                 21.    A sealed access driveway must be provided from Pitta Street to all parking and
                        manoeuvring areas of the development. The works must be undertaken generally in
                        accordance with Council’s Standard Drawings RS-049 and RS-050 and any associated
                        addendum.
                        Stormwater Drainage
                 22.    The site must be provided with a stormwater drainage system connecting to a lawful
                        point of discharge. Stormwater runoff from the development must be disposed of on-
                        site without causing scour or damage to the subject site or any adjoining property and/or
                        discharged to the existing kerb and channel in Pitta Street.
                        Earthworks and Retaining Walls
                 23.    All earthworks must be carried out in accordance with a site specific Geotechnical
                        Investigation/Report prepared by a qualified person* and endorsed through a Building
                        approval.
                 24.    The site specific Geotechnical Investigation/Report must consider the potential for the
                        works to encounter acid sulfate soils and must include, but not be limited to:
                        d.      Soil investigation and testing
                        e.      Where Acid Sulfate Soils are likely to be encountered, inlcude an Acid Sulfate
                                Soils Management Plan that considers the treatment of the soils and where
                                relevant, export of the soils from the site
                        *(Refer to Advisory Note)
                 25.    All earthworks and associated retaining structures/batters, both above and below ground
                        level, both temporary and permanent, must be contained entirely within the subject site
                        unless written permission from the respective landowner(s) is provided to Council.
                 26.    All earthworks must be undertaken in accordance with the provisions of Australian
                        Standard AS3798: Guidelines on Earthworks for Commercial and Residential
                        Developments.
                 27.    All retaining walls must be designed and constructed in accordance with the planning
                        scheme and must be certified by an RPEQ where exceeding 1.0m in height. All retaining
                        walls that are publicly accessible and exceed 1.0m in height must be fitted with a
                        commercial grade safety fence.




                                                                                                         Page 5 of 9
Document Set ID: 22621442
Version: 4, Version Date: 19/10/2023                                                             Print Date: 19 October 2023, 3:25 PM
Log in to download the original file

Bulk_20231019152518.pdf · 160 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.