Figure 6.1 illustrates the DRAINS Model layout.
Figure 6.1 – Drains Model Layout
Peak flow rates determined for each 3 cases are outlined in Table 6.5.
Table 6.4 – Comparison of Peak Flows (At year 2100)
Q5
AEP Q1 Q2 Q10 Q20 Q50 Q100
Storm (1EY) (0.5EY) (10%AEP) (5%AEP) (2%AEP) (1%AEP)
(0.2EY)
Existing 33 44 64 77 92 109 123
(L/s)
SCG Consulting engineers 14 SCG Ref: 33094(SWM).Rev A