Council archive · source document
06/2552 NEGOTIATED Decision Notice [As Published] · 132006.2552
Form 6 - Negotiated Decision Notice
INTEGRATED PLANNING ACT 1997, S3.5.15, IDAS DEVELOPMENT APPLICATION
File No: 2006/2552 Date of Decision: 30 August 2007
1. APPLICANT DETAILS
Name: Raphill Pty Ltd
Postal address: CARE Ken Hicks & Associates Pty Ltd
PO Box 6380
MAROOCHYDORE BC QLD 4558
Phone no: 5471 3401 07 5443 Fax no: 617 5443 7146
2844
2. PROPERTY DESCRIPTION
Street address: 228 David Low Way Peregian Beach, 226 David Low Way Peregian Beach
Real property Lot 1 RP 152737, and part of Lot 78 P: 9311 County of March, Parish of Weyba
description:
3. OWNER DETAILS
Name: Raphill Pty Ltd
Postal address: PO Box 186
PEREGIAN BEACH QLD 4573
4. REFERRAL AGENCIES
Referral Agency Address Basis
Environmental GPO Box 2771 Brisbane Qld 4001 Concurrence Agency
Protection Agency
5. APPLICATION TYPE
Development Development Details Preliminary Development
Approval Permit
Material Change of Use Visitor Accommodation Type 4 - No Yes
Motel
6. DECISION DETAILS
Council on 21 June 2007 decided to approve the application and grant a Development Permit, subject to
conditions.
In relation to representations made by the applicant Council on 30 August 2007 decided to:
A. Agree to amend Conditions 3.1, 3.4.1, 3.5 and 11.
B. Issue a Negotiated Decision Notice.
7. APPLICABLE CODES
The developer must comply with the following codes for self-assessable development related to the development
approved under this Development Permit:-
Advertising Devices Code.
8. SUBMISSIONS
One. See attached list.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 14 pages
Page 2
NOOSA COUNCIL IDAS Development Application Decision Notice 2 of 15
9. CONDITIONS
The approval is subject to conditions. Noosa Council’s conditions are attached. Conditions from the
Environmental Protection Agency, as a concurrence agency are also attached.
10. FURTHER DEVELOPMENT PERMITS REQUIRED
Type of Development Permit required Subject of the required Development Permit
Development Permit For Building Works All Building Works
Development Permit for Operational Works Landscaping, car parking & access, frontage works,
stormwater drainage, erosion & sediment control, road works
and site civil works
11. RIGHTS OF APPEAL
Rights of appeal in relation to this application are attached.
12. ASSESSMENT MANAGER
Name: Noosa Council Signature: Date: 30 August 2007
AOP2 c:\docume~1\aop2\locals~1\temp\bcl technologies\easypdf 5\@bcl@b808a965\@[email protected]
Page 3
NOOSA COUNCIL IDAS Development Application Decision Notice 3 of 15
Noosa Council Conditions
INTEGRATED PLANNING ACT 1997, IDAS DEVELOPMENT APPLICATION
Land Use
1. Development undertaken in accordance with this approval must generally comply with the
approved plans of development. The approved plans titled Site Plan Drawing, Ground Floor Plan,
First Floor Plan, Ground Floor Plan Dimensions, First Floor Plan Dimensions, Elevations (1),
Elevations (2) and Roof Sheet Layout all numbered Drawing No. 6164 prepared by design studio
and dated 10 March 2007 and as may be amended by these conditions. Notwithstanding this the
screens, finishes and other architectural treatments, as illustrated in the plans, for the David Low
Way elevation, must be incorporated into the building to the reasonable satisfaction of the
Manager Land Use.
2. The development must be undertaken and operated in a manner that causes no detrimental effect
upon the amenity of the neighbourhood by reason of the creation of excessive noise, lighting
nuisance or other emissions.
3. The open space and setback areas are to be landscaped in accordance with Council’s Policy on
Landscaping Guidelines and a properly prepared landscape plan prepared by a suitably qualified
Landscape Architect or Horticulturalist. Such landscaping is to be completed prior to the premises
being occupied and maintained at all times thereafter. These landscape plans shall demonstrate
the following:-
3.1. The provision of screening vegetation of local origin to all property boundaries excluding the rear
property boundary and the front setback area;
3.2. The provision of a minimum of 0.5 metres of dense screening vegetation of local origin between
the pool and the rear property boundary;
3.3. Three (3) x 100 Litre species of local origin shall be provided in the uncovered hardstand areas
adjacent to ‘carpark 14 and 15’ to soften the built form of the development;
3.4. The provision of dense screening vegetation of local origin to the 6 metre frontage setback area
excluding the area designated ‘carpark 13’;
3.4.1. Dense screening vegetation of local origin shall be provided between ‘carpark 13’ and
the front property boundary; and
3.5. The existing Pandanus tectorius located along the northern side boundary shall be retained and
appropriately maintained.
4. Existing trees on the site and within road reserves are to be retained, except where required to be
removed due to building operations or the conduct of the approved use. These landscape plans
required to be submitted are to denote areas of existing vegetation or existing trees proposed or
required to be retained.
5. Cleared vegetation is to be suitably processed by one of the following methods and removed from
the site:-
5.1. Processing through a woodchipper or shredder. The resulting mulch is to be stockpiled loose in
heaps of less than 1000 cubic metres, less than 2.5 metres high with a minimum of 10 metres
between edges of heaps.
5.2. Disposal for firewood.
5.3. Disposal for landscaping purposes.
5.4. Transport to alternative site for breaking down materials provided that all necessary permits have
been obtained to allow the alternate site to be used for this purpose.
AOP2 c:\docume~1\aop2\locals~1\temp\bcl technologies\easypdf 5\@bcl@b808a965\@[email protected]
Page 4
NOOSA COUNCIL IDAS Development Application Decision Notice 4 of 15
5.5. The disposal method for clearing works is to be submitted in conjunction with an application for a
Development Permit for Operational Work. The Applicant is advised that other methods may be
considered provided full details of the method are submitted.
5.6. The Applicant is advised that burning off is an unacceptable method of disposal.
6. Any advertising sign or device is to comply with Council's policies on advertising.
7. The developer shall provide noise attenuation fencing to the rear property boundary adjacent to
pool and the northern property boundary to preserve the acoustic amenity for adjoining properties.
8. All fencing shall be setback at least 1 metre from the front property boundary, with at least half of
the fencing setback 2 metres. The area of land between the fence and the front property boundary
shall be densely landscaped to screen any fencing from the street.
9. Site cover for the development shall not exceed 40%.
2
10. The Gross Floor Area of the development shall not exceed 528 m .
11. The development shall be no greater than two (2) storeys and shall not exceed a maximum
building height of 8.0 metres as measured from the natural ground level.
12. The ‘inhouse dining area’ shall only be available to guests residing at the visitor accommodation.
13. The development shall consist of no greater than twelve (12) visitor accommodation units and no
more than one (1) manager’s dwelling unit.
14. The population density of the site shall not exceed 18.2 persons.
15. Any deck or balcony areas are not to be enclosed with shutters, glass panelling or the like, thus
remaining as open structures.
16. The external walkway areas shall contain openings as indicated on the approved plans and
therefore shall not be enclosed.
17. The proposed development shall have all kitchen, laundry and bathroom fittings that comply with
the AAA Water Conservation Rating System as defined by the AS/NZS 6400 (Water Efficient
Products - Rating and Labelling 2003) and AS/NZS 3500 (National Plumbing and Drainage
Standard Part 1.2), with toilets to comply with the AAAA Water Conservation Rating System. All
tap ware and shower roses shall not exceed a maximum flow of 9 litres per min. Dishwashers and
washing machines are excluded from this requirement.
18. The subject site is located within an area previously contaminated by Unexploded Ordnance
(UXO). Whilst the site has been given clearance by the Environmental Protection Agency, care
should be exercised while excavation works for the proposed development are undertaken. For
further information contact the Environmental Protection Agency. Should a device be found during
building or excavation works, all work should cease and the police contacted immediately.
19. The requirements of this development approval are to be effected, prior to the use of the premises.
Council reserves the right to call upon the bond or guaranteed sum referred to in this approval to
effect compliance with conditions.
20. Security in the form of a cash bond or trading bank guarantee to the sum of $25000 must be
submitted, to secure performance of all conditions of this approval, prior to the issue of a
Development Permit for Operational works. The cash bond or trading bank guarantee will be
returned on performance of the conditions of approval less any costs incurred by Council in
respect of enforcing performance of this permit.
21. The Development Permit for a material change of use of premises lapses if the use has not
happened by 21 June 2011, unless an application to extend the currency is approved by Council.
AOP2 c:\docume~1\aop2\locals~1\temp\bcl technologies\easypdf 5\@bcl@b808a965\@[email protected]
Page 5
NOOSA COUNCIL IDAS Development Application Decision Notice 5 of 15
Land Development
Lot Amalgamation
22. Any necessary boundary realignments or amalgamations of separate, adjoining lots that form part
of this application shall be completed in accordance with Section 3.7.3 of the Integrated Planning
Act and the Plan of Survey submitted for registration at the Land Titles Office. Proof of title being
issued for the amalgamated lot shall be submitted to Council prior to the issue of the Development
Permit for Operational Works.
Vehicle Access
23. A vehicular access driveway to serve the development shall be constructed from the David Low
Way frontage of the site with a maximum width of 5.5m. This access shall be a left in - left out
facility only.
24. The driveway shall be designed and constructed to Council’s design standards and to grades that
prevent vehicles from scraping and/or bottoming whilst also allowing pedestrians movements along
the footpath without any step or level difference. Should any driveways be constructed to grades
that do not comply with AS2890.1-2004, Council will require that the driveway be removed and
reconstructed to levels that do comply.
Please note, a step between the driveway and the footpath shall be avoided, as it is preferred to
have the footpath continue at a constant grade to minimise the potential for pedestrians to trip or
fall.
25. To ensure pedestrian safety between vehicles exiting the site and pedestrians on the footpath, the
driveway and any associated fencing or vegetation near the driveway shall comply with the
minimum sight line requirements as defined in AS2890.1, section 3.2.4. The applicant shall
demonstrate compliance by illustrating these sight lines on the plans submitted for both
Operational Works approval and Building Works approval.
26. All vehicles shall enter and leave the site in a forward direction.
Car Parking
Off Street
27. Carparking shall be provided within the site as shown on drawing number 6164 Sheet 5 dated
10/03/07 by Design Studio, except as modified herein.
28. A minimum of 15 carparking spaces shall be provided on site, including 1 clearly defined disabled
carpark space.
29. The carparking area shall be designed to comply with the provisions of AS 2890.1-2004 for user
class 2 with allowance for vehicles to enter and leave the site in a forward gear and with a
minimum head clearance (headroom) at any point of 2.2m.
30. The columns of the building shall be designed to comply with Figure 5.2 of AS 2890.1-2004.
31. All carparking shall be kept, maintained and line-marked in a condition fit for use.
Vegetation Protection & Preservation
32. Vehicular pavements within the drip zone of any of the existing trees on site to be retained shall be
designed as a pervious pavement (such as grass paving cells or similar), as this will allow water
that falls on this surface to penetrate to the trees root system. The pavement shall be constructed
so as not to damage the tree or their root system and in this regard temporary fencing shall be
provided around the trees during construction to help protect them.
Plans shall be submitted to the Council for approval that clearly show the type and extent of the
pervious pavement and the temporary fencing prior to obtaining a Development Permit for
Operational Works.
Frontage Works
33. Footpath improvements such as topsoiling, grassing, and tree planting are required to the David
Low Way frontage of the site in accordance with Planning Scheme Policy PSP03 Landscaping
Plants & Guidelines. Grass shall be couch, free of weeds.
34. A new 2.0m wide concrete path shall be constructed along the David Low Way frontage of the site
in accordance with Council’s design standards and to an alignment that protects any significant
vegetation or any underground services.
AOP2 c:\docume~1\aop2\locals~1\temp\bcl technologies\easypdf 5\@bcl@b808a965\@[email protected]
Page 6
NOOSA COUNCIL IDAS Development Application Decision Notice 6 of 15
35. All paths, pram ramps, driveways and parking areas shall be designed and constructed to ensure
pedestrian safety using non-slip materials, to produce an evenly graded surface finish, and to be in
accordance with the Disability Discrimination Act 1992 and Australian Standard 1428.1 Design for
Access & Mobility.
36. All redundant vehicular crossings to the site shall be removed and replaced by kerb & channel,
footpath paving and landscaping such as trees and grasses in accordance with Council’s Standard
specifications prior to commencement of the use permitted by this permit.
Roof Water & Stormwater Drainage
37. Roof runoff from the new building shall be directed to a rainwater storage system or tank (minimum
storage 9000 litres) that is installed to ensure water from the tank is used for external uses (such
as watering gardens, irrigation, ornamental ponds, water features, topping-up swimming pools,
outdoor cleaning, etc) and for use in flushing of toilets internal to the building. All rainwater tanks
are to be designed and installed in accordance with the Queensland Development Code (QDC),
Part 25 – Rainwater Tanks, and shall be part of the plumbing application in conjunction with the
building approval. The location and capacity of the tanks shall be clearly shown on the plans
submitted for Operational Works approval and any overflow shall be directed to the road frontage.
38. All stormwater drainage (including roof water overflow from the rainwater storage system) shall be
collected and discharged so there is no net increase in stormwater runoff from the site.
Stormwater drainage permitted to drain from the site shall be discharged to Council’s:
38.1. existing drainage structures in David Low Way. Plans of the drainage design shall be prepared by
a Registered Professional Civil Engineer and submitted to Council prior to obtaining a
Development Permit for Operational Works, and/or
38.2. kerb & channel street drainage system in David Low Way. Plans of the drainage design shall be
prepared by a Registered Professional Civil Engineer and submitted to Council prior to obtaining a
Development Permit for Operational Works.
The maximum discharge of stormwater drainage allowable to Council’s kerb & channel
street drainage system at any one location is 25 litres/second.
39. As the site is proposed to be filled, appropriate stormwater drainage pipes shall be installed within
the site to collect and discharge stormwater runoff from all adjoining properties to prevent
additional ponding/flooding on these properties.
40. To ensure that polluted run-off does not enter Council’s stormwater drainage system, stormwater
run-off from the carparking areas and the driveways shall have the first flush (the first 12 mm of
rainfall or hose-down) collected in a grease/oil arrestor provided on site prior to being permitted to
discharge into Council’s drainage system.
All other clean stormwater, such as roof water, can be collected on site and discharged through a
single underground drain line directly into the existing drainage system, bypassing the grease/oil
arrestor.
To this end, a detailed maintenance plan shall be prepared for the proposed grease/oil arrestors,
which shall be submitted to the Council prior to obtaining a Development Permit for Operational
Works.
The approved maintenance plan shall be incorporated in the management of the development and
a copy of this shall be provided for Council’s records prior to commencement of the approved Use.
A Development Permit for Building Works shall not be granted until a Development Permit for
Operational Works has been issued in regard to the drainage scheme.
41. All site stormwater drainage shall be by means of a gravity system.
Sewer Mains
42. The site shall be connected to Council’s existing sewerage reticulation systems and be constructed
in accordance with Council’s standards and requirements at no cost to Council.
43. The existing sewer main that traverses the site and the ‘zone of influence’ (taken as the area within
a 45-degree angle measured from the invert of the sewer main to the finished surface level) shall
be accurately located and determined by a licensed Surveyor and shown on all plans submitted for
Operational Works approval.
To ensure Council’s sewer main is accessible for maintenance purposes and is protected from risk
of damage no structures requiring a building permit (eg. buildings, swimming pools, retaining walls
exceeding 1m in height, raised terraces, etc) shall be constructed within this ‘zone of influence’ or
within 1.5m of the centreline of the sewer main, whichever is the greater. As such the applicant
shall amend Operational Works plans including Building plans to ensure compliance.
AOP2 c:\docume~1\aop2\locals~1\temp\bcl technologies\easypdf 5\@bcl@b808a965\@[email protected]
Page 7
NOOSA COUNCIL IDAS Development Application Decision Notice 7 of 15
Town Water Supply
44. The site shall be connected to Council’s existing town water supply and be constructed in
accordance with Council’s standards and requirements at no cost to Council.
45. Each individual water connection to the water reticulation system shall extend to the property
boundary and be metered. All fees for the supply of water meters shall be paid to the Council.
46. All water meters must be located outside the property boundary and in an easily assessable
location to facilitate unhindered reading by Council and/or Council’s contracted water meter
readers, and not behind fences or locked gates. In this regard approval of the water meter
configuration and location must be obtained from Council’s Water & Sewerage Capital Works
Manager prior to lodgement and approval of hydraulic drawings.
Service Easements
47. A registered easement shall be created over the zone of influence of all sewers within the subject
site and over those parts of the subject site that are impacted upon by sewers on any adjoining
sites. The easements shall generally be parallel to and centred over the sewer main and be
equivalent in width to twice the depth to invert level of the sewer at the deepest point within the
allotment (measured from the finished surface) and be no less than 3.0m wide overall. In this
regard a licensed surveyor shall accurately locate all sewer mains and determine the necessary
width of the easement, which shall be shown on any plans submitted for Operational Works /
Building Works approval. To this extent the surveyor shall certify that the sewer and the zone of
influence is wholly contained within the easement to be created.
In addition to this the Applicant’s Solicitor shall give Council’s Solicitor an appropriate undertaking
in writing that the Title Deed and the easement documents will be lodged at the Land Titles Office
and any additional Titles Office forms or requisitions requiring the consent of Council will be
attended to promptly.
A duly executed copy of the easement shall be submitted to Council for perusal prior to the use
commencing.
Any changes required by Council’s Solicitor must be corrected immediately.
48. No building or other structure shall be constructed or encroach over an easement.
Earthworks
49. Earthworks required on site shall be carried out in accordance with Section 3.8 of Council’s
Engineering Design Standards Manual and so as not to cause the additional ponding of water on
any adjoining lands or the blockage of, or interference with, any natural watercourses. Detailed site
surveys indicating natural surface levels and contours of the adjoining properties must be provided
with the application for a Development Permit for Operational Works for Filling and Drainage.
This may require the design and construction of drainage pipes and/or an overland flow-path within
the development site that caters for drainage from the adjoining sites for a design storm with an
Average Recurrence Interval of 1 in 100 years. A private easement for the Drainage of Water
encompassing the drainage pipes or overland flow-path will also be required. In this regard a
Development Permit for Operational Works shall be obtained.
Should evidence be provided to Council indicating that no additional ponding of stormwater will
occur on the adjoining properties the requirement for the drainage pipes, overland flow-path and
easement shall not apply.
50. Earthworks carried out on site shall not affect the structural integrity of any of the existing fences or
structures that border the development site. Fences that are affected shall be replaced prior to the
Building Certifier issuing the Certificate of Classification. In this regard any fences to be replaced
shall be clearly shown on the plans submitted for Operational Works approval.
Acid Sulfate Soils
3
51. As the site is located below the 5m AHD, any excavation works consisting of 100m or greater
3
and/or any filling works consisting of 500m or greater and with an average depth of 0.5m or
greater will need to be carried out in accordance with State Planning Policy 2/02 Planning and
Managing Development Involving Acid Sulfate Soils. In this regard appropriate testing and
supporting documentation prepared by a suitably qualified specialist shall be submitted to Council
for approval prior to obtaining a Development Permit for Operational Works.
AOP2 c:\docume~1\aop2\locals~1\temp\bcl technologies\easypdf 5\@bcl@b808a965\@[email protected]
Page 8
NOOSA COUNCIL IDAS Development Application Decision Notice 8 of 15
Site Stability
52. A Geotechnical Engineer or similar qualified expert shall assess the soil condition on site,
determine the soil classification, establish whether any measures are required to protect the
stability of adjoining buildings and/or structures and/or land, and make recommendations on the
type of foundation system(s) best suited for the proposed development. The recommendations of
this report shall be incorporated into the design and construction of the proposed development.
Erosion and Sediment Control
53. Any person acting on this permit shall prevent erosion and sediment export from leaving the site.
Site control measures such as silt fencing, controlled gravel access to the site and controlled
disposal of waste, will be necessary.
In this regard plans detailing the methods of controlling erosion and sediment are required to be
submitted to the Council for approval prior to obtaining a Development Permit for Operational
Works.
Contributions Towards Council Infrastructure
54. Monetary contributions shall be paid to Noosa Council towards the cost of providing and/or
upgrading various infrastructure at the rates applicable at the time of payment. An estimate only of
the contribution amounts under the current Council policies and requirements is outlined in the
table below:
Contribution Required For: Amount:
PSP12 – Public Open Space Contributions (Park) $16,444
PSP16 – Sewerage Headworks Contributions $56,832
PSP17 – Water Supply Headworks Contributions $37,400
PSP20 – Pathway Trunk Network Contributions $3,696
TOTAL Contribution Amount = $124,876
Please note, that these amounts are all subject to variations in the Consumer Price Index, All Groups Brisbane
from March 2007 until the date of payment.
All contributions must be paid prior to the issue of a Development Permit for Operational Works.
Alternatively a trading bank guarantee shall be submitted to Council plus 20%. Should the
contributions not be paid at the due time, Council shall call upon the trading bank guarantee in full.
Processing of bonds for security where specific Council approval has been given for the bonding of
contributions will incur an administration fee in accordance with Council’s Land Development
Commercial & Regulatory Fees at the time of lodgement.
In the event that the Development Permit for Material Change of Use of Premises lapses or is
cancelled, the trading bank guarantee will be returned.
General
55. A suitably qualified Registered Professional Engineer shall prepare engineering drawings and
specifications for all engineering works that will become Council infrastructure, which shall be
submitted in conjunction with an application for a Development Permit for Operational Works. In
this regard a DXF/DWG file on GDA94 zone 56 grid of the proposed cadastre layout is to be
submitted in conjunction with any application for Operational Works.
56. To facilitate production of As Constructed drawings it is suggested that all design drawings are
submitted in the Asset Design and As Constructed (ADAC) digital format. (Guidelines on the use of
ADAC are available at www.adac.com.au).
57. Any damage caused to any public utility during the course of construction shall be repaired to
Council’s standards and at no cost to Council.
58. Any alteration of any public utility or other facilities necessitated by the development of the land or
associated construction works external to the site shall be at no cost to Council.
59. The transportation of all materials to and from the site shall be undertaken in a manner such that
no particle matter escapes onto a public road. All vehicles carrying materials either to or from the
site shall be covered to prevent materials including dust being windblown from the vehicle.
AOP2 c:\docume~1\aop2\locals~1\temp\bcl technologies\easypdf 5\@bcl@b808a965\@[email protected]
Page 9
NOOSA COUNCIL IDAS Development Application Decision Notice 9 of 15
60. As Constructed drawings and data shall be certified by a qualified experienced Civil Engineer for
design intent, and a Licensed Surveyor shall certify the cadastre and the location, level and type of
all services and structures. All of which shall be submitted to Council for checking and for
Council’s records.
The data must fully detail levels for all engineering works including but not limited to drainage
structures, finished ground levels and pavement surface levels. The data shall be submitted in the
Asset Design and As Constructed (ADAC) digital format. (Guidelines on the use of ADAC are
available at www.adac.com.au).
61. Approval of works shall not be granted until all As Constructed information has been supplied and
accepted by Council.
Environmental Health
62. The developer must provide waste storage and disposal facilities in accordance with Planning
Scheme Policy No. 9 “Waste Management Multi-Dwellings and Commercial and Industrial
Premises”, including an external imperviously paved area correctly sized for all refuse and
recycling containers and suitably screened from public places and neighbouring properties. A bin
wash area is required with a cold-water tap, hose and drain outlet connected to sewer, via a bucket
trap. The drain outlet is to be designed to prevent storm water entry to the sewerage system and
this can be achieved with a nib wall 50mm high and up to 700mm x 700mm wide (max 0.5m²), or
alternatively the waste area can be roofed, or any other design approved by Council.
63. Noise emission from mechanical equipment (air conditioners, refrigeration equipment or pool
pumps etc) shall comply with the following requirements:
The equipment shall be installed and located in a manner that prevents excessive noise in
accordance with Council’s Local Law No. 12 - Control of Nuisances. Infringement Notices (on-the-
spot fines) may apply for offences.
A person must not use equipment on any day if it makes or causes noise to be made –
From 10pm to 7am: More than the lower of either –
40 dB(A)
3 dB(A) above the background noise level
No audible noise for pool pumps apply during these hours.
From 7am to 7pm: More than the lower of either –
50 dB(A)
5 dB(A) above the background noise level
From 7pm to 10pm: More than 3 dB(A) above the background noise level.
64. Submission of written certification from a suitably qualified person confirming that the noise levels
from all mechanical equipment comply with the cause above when measured at either the
residential boundary or outside the most exposed part of an affected building, whichever is the
closest to the equipment.
The assessment and certification is required immediately after installation of the equipment and
prior to any occupation of the building, and in a format approved by Council. This assessment
must take into account noise from any other fixed equipment on the property e.g. swimming pool
pump, heating/cooling equipment, etc that may increase the overall noise level emitted.
Advice: It is highly recommended that the person you engage to certify the installation is involved at the
plan development stage so they can recommend where this equipment is best located. They can also
advise about noise enclosures and can make other suggestions to avoid noise problems. It is a lot more
costly to try and deal with noise problems after everything is built.
Trade Waste
65. The hydraulic drawings are to show all the Trade Waste requirements in accordance with the
Noosa Trade Waste Policy. NB: A Trade Waste Permit must cover all types of Trade Waste
discharged.
66. The Trade Waste application fee of ($105.00) is required at the time of the application.
AOP2 c:\docume~1\aop2\locals~1\temp\bcl technologies\easypdf 5\@bcl@b808a965\@[email protected]
Page 10
NOOSA COUNCIL IDAS Development Application Decision Notice 10 of 15
67. Trade Waste requirements are to be in place, inspected and approved prior to the commencement
of trading or operation. The appropriate Trade Waste Permits will be issued following approval at
final inspection.
68. A place of food preparation and/or cooking is to have the liquid waste connected to a Trade Waste
line, that discharges to an approved grease arrestor of a size determined by Council’s Trade
Waste Policy.
69. The floor of the bin wash area is to fall to a bucket trap with the waste pre-treated by a grease
arrestor prior to discharge to the sewer and also an appropriate backflow prevention devise is to be
installed. Rainwater is to be excluded from the bin wash area and if in excess of 700mm x700mm
(max 0.5m²) it is to be roofed.
AOP2 c:\docume~1\aop2\locals~1\temp\bcl technologies\easypdf 5\@bcl@b808a965\@[email protected]
Page 11
NOOSA COUNCIL IDAS Development Application Decision Notice 11 of 15
Local Laws, Policies & State
Regulation Requirements
INTEGRATED PLANNING ACT 1997, IDAS DEVELOPMENT APPLICATION
THE FOLLOWING ADVICES ARE FOR INFORMATION PURPOSES ONLY AND DO NOT FORM
CONDITIONS OF APPROVAL
1. The applicant is advised that development contributions and infrastructure charges applicable to this
development approval have been based on the following Uses Class/ Uses and applicable quantities:-
Existing Development Approved Development
Existing Use Class / Approved Use Class /
Existing Quantity Approved Quantity
Use Use
Visitor Accommodation –
Detached House 0 12 x 1 Bedroom Units
Type 4 Conventional
Multiple Housing - Type 4
Detached House 0 1 x 1 Bedroom Units
– Conventional
2. The applicant is informed that approval of this development application will trigger an Infrastructure
Charge in accordance with the Coastal Major Road Network Infrastructure Charges Plan for the estimated
amount of $10,504 and is subject to variations in the Consumer Price Index, All Groups Brisbane from
March 2007 until the date of payment. An Infrastructure Charge Notice will be issued in accordance with
Chapter 5 of the Integrated Planning Act 1997.
3. The applicant is informed that payment via credit card transaction will not be an acceptable method
of payment for development contributions conditioned in this permit or for infrastructure charge
notices issued separately.
4. The applicant is advised that a Compliance Permit for all plumbing and drainage works within the
boundaries of the development site shall be obtained from Council’s Plumbing Services Section
prior to obtaining a Development Permit for Building Works.
5. This proposal has not been assessed in relation to the spread of fire between properties /
buildings. It is the building certifiers responsibility to assess the requirements for fire services, fire
separation and appropriate methods of construction as part of the building works approval process.
Referral to the Queensland Fire and Rescue Service (QFRS) may be required as part of the
Building Approval process.
6. Fencing to the swimming pool must comply with the Queensland Building Act 1975 Part 3 (as
amended) and Part 5 of Standard Building Regulation 1993 in all respects. Direct access from the
dwelling to the pool enclosure is not permitted.
7. Pursuant to the Building and Construction Industry (Portable Long Service Leave) 1991 Act if the
cost of operational works exceeds $80,000, then a portable long service leave levy is required to
be paid. In accordance with Section 77.(1) of the Act, Council is required to sight the approved
form issued by the Building and Construction Industry (Portable Long Service Leave) Authority that
confirms that the requirements of the Act have been satisfied. A statutory declaration outlining the
cost of the operational works must be submitted to Council with the lodgement of any application
for operational works over the site.
8. Where any food premises is included in a development, the following is required:
8.1. Plans and application is to be made to Council’s Environmental Health Section for approval prior to
any building approval, fitting out or use of the premises.
8.2. A statement indicating the purpose of the food premises, type of food sold, proposed menu and
maximum number of patrons at any time, is to accompany the application for plan approval.
AOP2 c:\docume~1\aop2\locals~1\temp\bcl technologies\easypdf 5\@bcl@b808a965\@[email protected]
Page 12
NOOSA COUNCIL IDAS Development Application Decision Notice 12 of 15
8.3. Construction and use of the food premises should comply with Council’s Food Premises Policy and
the Food Safety Standards. (Both available from Council)
8.4. Toilets for customers and staff to be provided in accordance with Building Code of Australia.
Obtain advice from a building certifier on numbers and standards, including disable access.
8.5. Plans and approval is required for any mechanical exhaust ventilation system, which should
comply with AS1668. A certificate from the installer certifying the system complies with the
Standard must be obtained and lodged with Council prior to commencement of trade.
8.6. Any Licensable Food Business, as defined in Chapter 3 of the Food Act 2006, must obtain a Food
License from Council, prior to use of those premises.
9. The development should be undertaken and operated in a manner that causes no detrimental
effect upon the amenity of the neighbourhood by reason of the creation of excessive noise,
lighting, air-borne hazards, atmospheric pollutants (including dust or odours) nuisance or any other
emissions in accordance with the nuisance provisions of the Environmental Protection Regulation
1998 or Council’s Local Law No. 12 – Control of Nuisances.
10. Noise from building works associated with commercial and or industrial development should
comply with the following –
10.1. Limited to between 7:00am to 6:30pm Monday to Saturday.
10.2. All reasonable measures are taken to minimise noise emissions.
10.3. Not permitted on Sunday or public holidays.
11. In accordance with the Environmental Protection (Water) Policy 1997, all sand, silt, mud, paint,
cement, concrete, builder’s waste or rubbish should not be permitted to enter or be placed where it
could reasonably be expected to move into a roadside gutter, storm water drain or a watercourse.
On the spot fines apply for such offences.
12. The plans for the proposed building work have not been assessed for compliance with the
requirements of the Building Code of Australia as they relate to people with disabilities. Your
attention is drawn to the matter that either or both the Disability Discrimination Act
1992(commonwealth) and the Anti-Discrimination Act 1991 (Queensland) may impact on the
proposed building work.
AOP2 c:\docume~1\aop2\locals~1\temp\bcl technologies\easypdf 5\@bcl@b808a965\@[email protected]
Page 13
NOOSA COUNCIL IDAS Development Application Decision Notice 13 of 15
List of Submitters
INTEGRATED PLANNING ACT 1997, IDAS DEVELOPMENT APPLICATION
Roberto & Kim Robazza
97 Elliot Street
Hawthorne Qld 4171
AOP2 c:\docume~1\aop2\locals~1\temp\bcl technologies\easypdf 5\@bcl@b808a965\@[email protected]
Page 14
NOOSA COUNCIL IDAS Development Application Decision Notice 14 of 15
Appeal Rights
INTEGRATED PLANNING ACT 1997, IDAS DEVELOPMENT APPLICATION
The following is an extract from the Integrated (6) If an application involves assessment against
Planning Act (Chapter 4). a concurrence agency code, appeal rights for
submitters for the application are not available
Division 8 - Appeals to court relating to
against the part of the approval that represents the
development applications
concurrence agency’s response for the code.
Appeals by applicants Appeals by advice agency submitters
4.1.27.(1) An applicant for a development application 4.1.29.(1) An advice agency may, within the limits of
may appeal to the court against any of the following- its jurisdiction, appeal to the court about the giving of
(a) the refusal, or the refusal in part, of a a development approval for a development
development application; application if-
(b) a matter stated in a development approval, (a) the development application involves impact
including any condition applying to the assessment; and
development, and the identification of a code (b) the advice agency told the applicant and the
1
under section 3.1.6; assessment manager to treat its response to the
(c) the decision to give a preliminary approval when a application as a submission for an appeal.
development permit was applied for;
(2) The appeal must be started within 20 business
(d) the length of a currency period; days after the day the decision notice or negotiated
decision notice is given to the advice agency as a
(e) a deemed refusal. submitter.
(2) An appeal under subsection (1)(a) to (d) must Appeals for matters arising after approval given
be started within 20 business days (the “applicant’s (co-respondents)
appeal period”) after the day the decision notice or
negotiated decision notice is given to the applicant. 4.1.30.(1) For a development approval given for a
development application, a person to whom any of
(3) An appeal under subsection (1)(e) may be the following notices have been given may appeal to
started at any time after the last day a decision on the the court against the decision in the notice-
matter should have been made.
(a) a notice giving a decision on a request for
Appeals by submitters extension of the currency period for an approval;
4.1.28.(1) A submitter for a development application (b) a notice giving a decision on a request to make a
may appeal to the court about- minor change to an approval.
(a) the giving of a development approval, including (2) The appeal must be started within 20 business
any conditions (or lack of conditions) or other days after the day the notice of the decision is given
provisions of the approval; or to the person.
(b) the length of a currency period for the approval. (3) Subsection (1)(a) does not apply if the
(2) The appeal must be started within 20 business approval resulted from a development application
(superseded planning scheme) that was assessed as
days (the “submitters appeal period”) after the day
if it were an application under a superseded planning
the decision notice or negotiated decision notice is
scheme.
given to the submitter.
(4) Also, a person who has made a request
(3) If a person withdraws a submission before the
mentioned in subsection (1) may appeal to the court
application is decided, the person may not appeal the
against a deemed refusal of the request.
decision.
(5) An appeal under subsection (4) may be
(4) If an application involves both impact
started at any time after the last day the decision on
assessment and code assessment, appeal rights for
the matter should have been made.
submitters are available only for the part of the
application involving impact assessment. Division 9 - Appeals to court about other matters
(5) If an application is processed under section Appeals for matters arising after approval given
6.1.28(2), appeal rights for submitters for the (no co-respondents)
application are available only for the aspects of the
development that would have required public 4.1.31.(1) A person to whom any of the following
notification under the repealed Act. notices have been given may appeal to the court
against the decision in the notice-
(a) a notice giving a decision on a request to change
or cancel a condition of a development approval.
1
Section 3.1.6 (Preliminary approval may override local planning
instrument)
AOP2 c:\docume~1\aop2\locals~1\temp\bcl technologies\easypdf 5\@bcl@b808a965\@[email protected]
Page 15
NOOSA COUNCIL IDAS Development Application Decision Notice 15 of 15
2
(b) a notice under section 6.1.44 giving a decision to
change or cancel a condition of a development
approval.
(2) The appeal must be started within 20 business
days after the day the notice of the decision is given
to the person.
(3) Also, a person who has made a request
mentioned in subsection (1)(a) may appeal to the
court against a deemed refusal of the request.
(4) An appeal under subsection (3) may be
started at any time after the last day the decision on
the matter should have been made.
Appeals against decisions to change approval
conditions under the repealed Act
4.1.33A.(1) A person who is dissatisfied with a
decision made on an application to change the
conditions attached to an approval given under
section 2.19(3)or section 4.4 of the repealed Act may
appeal to the court against-
(a) the decision; or
(b) a deemed refusal of the application.
(2) An appeal under subsection (1)(a) must be
started within 20 business days after the day notice of
the decision is to be given to the person.
(3) An appeal under subsection (1)(b) may be
started at any time after the last day a decision on the
matter should have been made.
Appeals against local laws
4.1.33B.(1) An applicant who is dissatisfied with a
decision of a local government or the conditions
applied under a local law about the use of premises
or the erection of a building or other structure
permitted by the planning scheme may appeal to the
court against the decision or the conditions applied.
(2) The appeal must be started within 20 business
days after the day notice of the decision is given to
the applicant.
2
Section 6.1.44 (Conditions may be changed or cancelled by
assessment manager or concurrence agency in certain
circumstances)
AOP2 c:\docume~1\aop2\locals~1\temp\bcl technologies\easypdf 5\@bcl@b808a965\@[email protected]