Minor Change Report MCU21 0117 02 (As Published) · MCU21/0117.02

of 29

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

               Existing Condition 48 (OPW approval)
               APPROVED PLANS
               48.    Development undertaken in accordance with this approval must generally comply with the
                      approved plans of development. The approved plans are listed in the following table unless
                      otherwise amended by these conditions.

                      Plan No.          Rev.                Plan/Document Name                    Date

                      7283_L01-01_G                         Landscape Notes and schedules         Sept 2023

                      7283_L03-01_G                         Landscape planting plan               Sept 2023


                      Amendments        The above plan is required to be amended to accommodate a 0.5
                                        metre wide landscape bed along the full length of the driveway
                                        (western side of driveway) from Pearl Street.

                      7283_L07-01_G                         Landscape Details                     Sept 2023

                      The following plans require amendment.

                      Plan No.           Rev.       Plan/Document Name                           Date

                      23098/SK10         G          Concept Site Levels and Drainage Plan        14/05/2024
                                         1. The drawing is marked as conceptual and includes a note
                      Amendments
                                            advising the drawing is not to be used for construction. Provide
                                            an amended plan that is suitable for Operational Works
                                            Construction for Council approval prior to the prestart meeting.
                                         2. Prior to the prestart meeting, provide an amended plan to Council
                                            for approval that includes the frontage works required in
                                            accordance with the MCU Conditions.
                                         3. Prior to the prestart meeting, provide updated engineering plans
                                            which specifically address the following:
                                               a.   A piped solution is proposed for Lot 1 SP153798. Due to the
                                                    proposed surface levels of the development driveway, when
                                                    events exceed the 2%AEP, or when blockage of the pipe inlet
                                                    occurs, flooding/ponding on the upstream lot will occur.
                                                    Revise the design to ensure that no ponding/flooding on the
                                                    upstream lot will occur in the 1%AEP event based on design
                                                    blockage allowance for any pipe system, consistent with
                                                    QUDM.
                                               b. Provide cross and long sections and hydrologic and hydraulic
                                                  calculations for the swales proposed in the following
                                                  locations:
                                                      i.    On the eastern boundary of the development site to
                                                            convey flows from outlet 2/1 to the LPD
                                                      ii.   From the driveway low-point to the bioretention basin
                                                     iii.   On the northern and eastern boundaries of Lot 1
                                                            SP153798 to convey runoff from the external
                                                            catchment to inlet 1/1

                                                                                                     Page 17 of 29



Document Set ID: 24138568
Version: 7, Version Date: 17/04/2026

Used in these records

About this file

File size
1.7 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Minor Change Report MCU21 0117 02 (As Published).pdf · 1.7 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.