Original source · versioned page text
Approved Plans - MCU26/0040, OPW26/0066 & RAL26/0013 (As Published)
Original PDF page 25, section 1. The text section number identifies this passage in the reader.
-
NOOSA COUNCIL
APPROVED PLAN NOTE:
MCU26/0040, OPW26/0066 & RAL26/0013 REFER TO STRUCTURAL ENGINEER'S DETAILS FOR
UNDERPINNING AND BUILDING AND FOOTING
7 AUGUST 2026
DESIGNS.
-
RPB
WALL OF EXISTING WAREHOUSE
EXISTING GROUND SURFACE
STAGE 3 STAGE 2 STAGE 1
BDY
BUILDING DRIVEWAY / PARKING BUILDING BUILDING DRIVEWAY / PARKING BUILDING
ENSURE FREE DRAINING
BEHIND BUILDING WALL
EXISTING SURFACE INDICATIVE FOOTING OF
DESIGN SURFACE PROPOSED RETAINING WALL
INDICATIVE FOOTING OF
- LOT 7 SP 237587 EXISTING WAREHOUSE
0.96m
FFL 125 FFL 125
0.50m
BDY
FFL 124.50 FFL 124.40 DETAIL 1 - INDICATIVE INTERFACE
STEP WITHIN
WITH EXISTING RETAINING WALL
BOUNDARY RETAINING TO BE ENTIRELY NOT TO SCALE
1.23m
BUILDING FOOTING
WITHIN DEVELOPMENT SITE - TO BE
BUILT WITH BUILDING WORKS 50mm STEP TYP
50mm STEP TYP
BULK EARTHWORKS ASSUMED NOTE:
300mm BOXING FOR PAVEMENT REFER TO STRUCTURAL ENGINEER
RETAINING WALL DETAIL 1 ABOVE
BOUNDARY RETAINING TO BE ENTIRELY
WITHIN DEVELOPMENT SITE - TO BE
BUILT WITH BUILDING WORKS - LOT 5 SP 197517
EX FFL 121.40
SECTION 1
SCALE HOR 1:200 C100 NEIGHBOURING
DEVELOPMENT BUILDING
SCALE VER 1:40
BDY
STAGE 2 STAGE 4
BUILDING DRIVEWAY BUILDING DRIVEWAY / CARPARKING
DESIGN SURFACE
TURFED BATTER 1 IN 4 MAX
B2 KERB
0.83m
FFL 125 FFL 125
BDY
p:\2576-18 taylor ct, cooroy\02 design\01 acad\c100-c120 bulk earthworks plan.dwg
1.72m
EXISTING SURFACE
SECTION 2 BULK EARTHWORKS ASSUMED
300mm BOXING FOR PAVEMENT
C100 0-600mm EDGE
SCALE HOR 1:250 THICKENING
SCALE VER 1:50 WHERE REQUIRED LANDSCAPED
BATTER 1 IN 3 MAX
PROJECT: JOB NUMBER
REV DATE DESCRIPTION BY CHKD DETAILS SCALE APPROVED PROPOSED INDUSTRIAL DEVELOPMENT
A 27.02.26 FOR APPROVAL GS DTB
Barlow Shelley Pty Ltd
ABN 29 679 702 599
AT 18 TAYLOR COURT, COOROY 2576
DATUM AHD
B 08.05.26 RESPONSE TO RFI GS DTB
DESIGN DTB
................. 07 5443 8285 FOR RMD CAPITAL PTY LTD
PO Box 899
DRAWN GS
AS SHOWN Engineer: TIM BURKE Maroochydore 4558 DRAWING TITLE: DRAWING NUMBER REV
[email protected]
DESIGN CHECK TB
(RPEQ 25245)
barlowshelley.com.au
EARTHWORKS TYPICAL SECTIONS (SHEET 1 OF 2) C120 B
DRAWING STATUS
DATE FEB 2026 This drawing is not to be copied or amended without written permission from Barlow Shelley Pty Ltd
FOR APPROVAL
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.