25 MPa concrete, pressure washed to expose aggregate.
AO.5m2 finished sample must be provided to the site
superintendent prior to commencement for approval, The
sample may form part of the final product. Amendments to the
aggregate mix ratios, depth of aggregate exposure or CCS.
saturation, may be made at this stage.
F62 Reinforcement located
PAVEMENT SCHEDULE
SEATING AREA IN FRONT GARDENS
JOINTS
+ Expansion joints to be at minimum 12m centres. To be located at edges of tile bands
where possible. 10mm thick closed ceil cross linked polyethylene foam or approved
equivatent.
1 erases
$34 me
Th
FOOTPATH PAVEMENT - DETAIL
central to the concrete width.
~_ Compacted sub-base and
SJ sub-grade Supply proof of
-——} compaction to site
superintendant,
+ Contraction joints to be at minimum 2.0m centres. Joints to be 25mm depth saw cut or
PAVING TYPE EXPOSED AGGREGATE
CONCRETE AS DETAILED
COLOUR CCS PAPERBARK
FINISH
10MM MARY RIVER
STONEAGGREGATE
FOOTPATH ALONG SHOP FRONT.
PAVING TYPE POUREO 125MM DEPTH
25MPA CONCRETE WITH
F62 LOCATED CENTRALLY
COLOUR NATURAL GREY
FINISH BROOM FINISH
PROVIDE IMPERVIOUS
MEMBRANE COATING TO
INSIDE OF PLANTER TO
MANUFACT. SPECIFICATIONS
PROVIDE GEOTEXTILE SURROUND
TO DRAINAGE CELL & AGGREGATE
LAYER
PROVIDE TOPPING LAYER
TO OBTAIN FALLS TO DRAINAGE
POINTS
PROVIDE AGGREGATE LAYER
TO TOP OF ORAINAGE CELL WITH
GEOTEXTILE SURROUND.
100mm MULCH
LAYER
SLOTTED PIPE
Smm BELOW PROVIDE 90 DIA SLOTTED
PIPE WITH GEOTEXTILE
SURROUND AND CAPPED TO.
TOP FOR MAINTENACE ACCESS
SELECT RENDER TO
MATCH BUILDING
ea ae”
Radius curve to!
corner of planters
PODIUM PLANTER DETAIL
PROVIDE IMPORTED
PODIUM MIX
PROVIDE DRAINAGE CELL
TO BOTTOM & SIDES.
CUT TO FIT (5mm TOLERANCE)
ORAINAGE LINE TO.
CONNECT TO STORMWATER
DRAINAGE SYSTEM
| 0 f
0)
50
ae
Spit Preventing Bracing,
Mi2 rod/bolt & fixings galvinised
all edges blunt,
Vertica! face to building
300mm Bollard spacings
to prevent vehicular access.
200x75 CCA treated Fi4
H'Wood posts.
All edges arrissed
finish with Koppers CN oil
or similar
CSC approved.
500
[ ‘Concrete footpath
{Concrete footing to Engineers detail
(300x400x600mm deep nominal)
100
—}-—Nominal size drainage aggregate.
400
FIXED TIMBER BOLLARD DETAIL NTS
PROPOSED PLANT SCHEDULE
"
K
y.
Code Botanical Name Common Name | ae read Size Oty.
x
TREES f
ALL equ Allocasuarina equisefitolia She-oak 7™m 2.5m 45 litre 8
BAC cil Backhousea citiodora Lemon Scented Myrtle | Gmto 15m) 2m 45 litre 5
BAN int Banksia integniolia Coastal Banksia 10m 3m 45 titre 7
DIP cam Diplogtottis campbell Small Leaved Tamarind) 6m “2m 45 lite 3
ELA ret Elasocarpus reticulatus Blueberry Ash 6m pm 45 live 10
PAN ped Pandanus pedunculatus * ‘Screw Pine 6m. en 200 litre 3
SHRUBS AND TUFTING PLANTS !
AUS dul Austromyrtus dulcis Midgon Berry 0.7m 4-2m 440 pot | 85
BAN rab | Banksia robur Swamp Banksia 1.5m 1.5m 200 pot 38
CALCap | Callistemon Captain Cook Bottlebrush 2m 1.5m 200 pot 4
CAL Eur | Catistemon Eureka Bottlebrush 4m 4.5m 200 pot 10
CAL LJ Caliistemon ‘Lite John’ im am 200 pot 33
CAR gla Carpobrotus giaucescens Little John Bottlebrush | 9.3m 0.5m 200 pot 50
OIA cae Dianewa caerulee Flax Lily O.Sm-1m | 9.5m 140 po, | 40
DIAton Dianetia longifolia Flax Lily 0.6m 0.5m 440 pot 2
GRERG | Greviles ‘Robyn Gordon’ Robyn Gordon 1m ‘1.2m 200 pot 40
MEL Cla | Melaleuca ‘Claret Tops' ‘A Owadl Paperbath 1.5in 1m 200p1 | 7
LOMcon | Lomandra confertifolia Little Con 0.3m 0.7m 440 83
LOM Ion Lomandra longifolia Mat Rush m \am 140 87
PAN jas Pandarea jasminoldes Pink Bower of Beauty | Climber Climber | 140por | 3
SYZAB Syzygium aus. "Aussie Boomer’ ly Ply 1.5m 1m soo po: | 4
SYzCas | Syzygiumcy. Cascade’ Lilly Pilly 3m 1.5m 300 pot | 9
TEC hit Tecomanthe hii Fraser Island Cimber | — climber gimber | 140p0t | 1
*Confirm all advanced stack selectians with LandGraphics prior
site delivery
X *Certification from the nursery is to be submitted to Councll, that the proposed Pandanus tec, var pedunculatus does not carry
the leaf hopper Jamelia australis, .
Plant No.s to be confirmad prior to
construction.
PLANTING DISTANCES
FROM SERVICES
min. DIST. _| SERVICE
3m. POWER POLE:
2m. UNDERGROUND SERVICES
am. STREETLIGHTS
2m, STORMWATER PIT
R
SUNSHINE GOA
EGIONAL COUNCIL
PLANS APPROVED
Signature:
appror, DIST, | DESCRIPTION
im, STRE!
FROM BACK OF KERB
0.5m, LANDSCAPING SETBACK WHERE.
VEHICLES FARK PARALLEL TO
KERB
STREET TREES MUST BE ABLE TO ATTAIN A
CLEAR TRUNK HEIGHT OF 1.9m ON MATURITY,
LANDSCAPE CONTRACTOR TO VERIFY
LOCATION OF ALL SERVICES &
BOUNDARIES PHIOR TO CONSTRUCTION,
BS ~ 15000
1 charge to Sunshine Cost
Price $165 00 plus gst
Trevor Roy
(Queendand Salas
|
Iteot Future Austalia Pty Lid
Be? Leitchs Ra Brenca’e OLD 4500
T. 4617 3205 1533
F. #61 7 3205 1536
MM, + 422 265 949
www. stroatturniture.com
supports powdercoated. Colour TBA
tens $470.00 each plus gst
wes $410.00 each plus pst
EXAMPLES: BENCH SEATING IN FRONT GARDENS
(
Planting Area
Turf
EXTRUDED CONCRETE EDGE DETAIL
Select Garden Sed Mulch
‘SPADE EDGE.
Ensure neal spade
edge is maintalned
to all street ees.
900min
sanerally Ox
depih of rootbatl
Ensure pit
edges are
tosmnny wh obey
porous “Generally ax width of roctbal)
PLANTING DETAILS - ADVANCED STOCK
NOTE:
Advanced tree stock planting
selection to council approval.
All street trees to have min.
1.2m clear trunk
£|
1800 x 50 x 50 Hwd slakes.
stakes to be chamfered, centrally
pointed & driven vertically Into
the ground outside the rootball
Approved securing material
such as Rubber tree ties or
50mm julemat/hessian tes
in figure 8 loops secured
loosely to tree & fixed to stake
with fathead galv. nails
100mm nom. compasied organic
mulch or counci approved. Form
shallow dish drain to base of tee.
Mound at pit edge
100mm deep friable imparted
topsof with 20% organic content,
light compaction only,
Tree pit to be excavated to min.
900 depth and backfilled witn
friable soll wilh max. 2% organic
content, light compaction only.
Slow release fertliser 10
manutacturers specifications
Backfill original subgrade
Rootball to sit on top of backfil
Cultivate subgrade
to 150mm depth
1:25@A1
LaNDGRAPHICS
(ANDEGAPE ARCHITECTS
Sa atten eso eiwre rang ray se
SS ren ake
Faw
Proposed Office Development
Davis Low Way, Peregian Beach
chon
Mr Erik Hipwood of MORGAN & BEIERS
Ate
‘Core Architects - John Roberson
ight compaction only.
ooh To
Operational Works Landscape Details
nos as
me 7]
ome | Me
Cae iho
sess teow
ome — = ane
uckHie] taca | coro c
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
08/0831 - Approved Plans [As Published]Related documentApplication case desk ↗
About this file
- File size
- 2.3 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.